Understanding Passive Probes

  Рет қаралды 19,661

Rohde Schwarz

Rohde Schwarz

Күн бұрын

Пікірлер: 9
@erikchavarin6085
@erikchavarin6085 5 ай бұрын
If I'm watching these videos, generally it's because I'm studying and stressed out. The birds chirping in the background really inspire serenity.
@mariofilippi3539
@mariofilippi3539 9 ай бұрын
Thanks for taking the mystery out how probes work.
@pauldenisowski
@pauldenisowski 6 ай бұрын
Thanks!
@ahmedalshalchi
@ahmedalshalchi 4 жыл бұрын
Very good basic knowledge presentation for the topic... I appreciate the presenter , fruitful one !!...
@pauldenisowski
@pauldenisowski 4 жыл бұрын
Thank you!
@yuvarajv758
@yuvarajv758 3 жыл бұрын
good work... well presented....
@Momibaily
@Momibaily 2 жыл бұрын
how does the probe tip cancel out scope input capacitance ? C1=C2 therefore net cap is C/2?
@pauldenisowski
@pauldenisowski 2 жыл бұрын
(See diagram at 2:51) At higher frequencies the capacitance the scope input will decrease signal level (essentially shorting the signal to ground). At higher frequencies, the parallel capacitance in the probe tip will "bypass' some of the resistance in the probe tip, increasing overall signal level. If we choose / adjust these capacitances properly, then we can balance out these two effects. Hope that helps!
@Jnglfvr
@Jnglfvr Жыл бұрын
Basically what you want to do is to maintain the 10:1 ratio of probe signal to input signal because that is what the scope is "expecting." The inevitable input capacitance of the scope acts like a low pass filter at higher frequencies attenuating them. Higher frequencies will reduce the net parallel input impedance of the scope and, being frequency dependent, you have no control over this. So the signal "seen" by the scope is lower than expected. So the probe impedance needs to be reduced to maintain that 10:1 ratio. To reduce the probe tip impedance one needs to increase probe tip capacitance (which will lower net parallel probe impedance). In this situation we say that the probe is undercompensated. Conversely if we reduce the probe impedance too much a higher voltage will appear at the input terminals and the probe is overcompensated.
Understanding Serial Protocols
9:03
Rohde Schwarz
Рет қаралды 19 М.
Understanding Differential Probes
10:44
Rohde Schwarz
Рет қаралды 10 М.
My MEAN sister annoys me! 😡 Use this gadget #hack
00:24
HELP!!!
00:46
Natan por Aí
Рет қаралды 54 МЛН
Lesson 3: Probing Part 1 - Compensating Passive Probes
11:30
Keysight Hands-On
Рет қаралды 18 М.
Understanding EMI Debugging with Oscilloscopes
9:39
Rohde Schwarz
Рет қаралды 21 М.
DIY Solder-In Oscilloscope Probes - Workbench Wednesdays
9:10
element14 presents
Рет қаралды 16 М.
Understanding Probe Compensation
6:24
Rohde Schwarz
Рет қаралды 21 М.
Understanding Oscilloscopes - Bandwidth
15:34
Rohde Schwarz
Рет қаралды 17 М.
Easy DIY passive #probe to measure #mains with the #oscilloscope
21:31
Accidental Science
Рет қаралды 10 М.
#9: Basic 1X and 10X Oscilloscope Probe tutorial
14:31
w2aew
Рет қаралды 232 М.
Understanding Active Probes
10:12
Rohde Schwarz
Рет қаралды 3,3 М.