This was exactly what I needed. My brain needs to process the what go where and why. Not just a wiring diagram. Thank you so much. I wish I could have posted the rats nest I had to deal left from the previous owner. I ripped it all out and confidently rewired using your explanation. Worked perfectly as I'm sure you would have expected. So thank you for the gift heat for Christmas. Me and my family are super comfortable now.
@JerseyMikeHVAC Жыл бұрын
Excellent!
@jamesberrell2356 Жыл бұрын
Fantastic video Mike,as all of them are! You’ve helped me immensely with my homes hydronic heating system. You’re a really good teacher! Cheers
@JerseyMikeHVAC Жыл бұрын
Thank you!
@stephencottens2521 Жыл бұрын
Just found your videos last week. As a 2nd year plumbing and really getting into heating this winter, your page has become a “ lightbulb “ type deal for me. Thank you. If youre looking for vigor suggestions love to see a drawing one of zins multiple pumps wired into a relay. Thanks again
@dmope2210 ай бұрын
I might be interested in that course. i like your explanation in your videos, which i used on my own sytem to find faults. awsome videos.
@bradc.12865 ай бұрын
Just what I was looking for. Simple and to the point.
@chadrayl9648 Жыл бұрын
I’m in year 3, an always refer back to your videos, thank you🤘
@brianmcdermott2430 Жыл бұрын
Thank you ,Mike. Great info.
@superbroolyy3 ай бұрын
Great video Thank you so much
@JohnDoe-ej1lw Жыл бұрын
Great learning for me mike..thanks bud
@ChuckKarl525Ай бұрын
I wired in a Taco zone valve controller which works great, but could I have wired the zone valves up without a controller and get the same performance?
@Drtbiker88Ай бұрын
That’s correct. I have a zone valve controller free system. All you need is a 24v transformer and do exactly what he said
@ChuckKarl525Ай бұрын
@Drtbiker88 Interesting, well the green boxes on the wall with yellow and red lights looks real nice anyway....lol
@ifz5680 Жыл бұрын
Great video Mike, thank you so much. Any news on the new course?
@JerseyMikeHVAC Жыл бұрын
It's a lot of work and I don't often have a lot of time, but I want to make sure it's done right. Going to take a while, but I'm making sure it's worth it.
@ifz5680 Жыл бұрын
@JerseyMikeHVAC All in time 😁, thanks again for your video's. They're very helpful.
@ReneCaceres-s9k3 ай бұрын
Waiting on the course.
@joemartinez-673Ай бұрын
Thank you 😎 🤟
@trentglasby677023 күн бұрын
Is the common wire also what they call the C wire? I’m trying to get these Nest Gen 3’s to work in my 2 wire system (I do have extra wires that aren’t being used going to my thermostats) but I need to find a way to tie into a C wire going to both zones! But like I said I’m lucky in the fact that they ran extra wire in my 2 wire system!
@Slickizme4 ай бұрын
Great vid
@marconantel7735 Жыл бұрын
How about an aquastat vid Mike? ZC, ZR, TV,ect..
@joshuatorres5542 Жыл бұрын
Legend
@JerseyMikeHVAC Жыл бұрын
Thank you, brother.
@timjohnson6727 Жыл бұрын
question, you mentioned at the end that some people use the ZC terminal instead of the C terminal. wouldn't the circ be powered every time during the call from the low limit even without the t-stat call for heat ?
@JerseyMikeHVAC Жыл бұрын
I said TV and T at the end there, not ZC and C.
@cdenneen11 ай бұрын
Your older videos show the R transformer to yellow zone valve. These show it bypassing the yellow and using the white to put power to zone valve. Is there benefit to sending the 24 directly to Tstat here vs sending it through the zone valve. Difference here is the zone valve doesn’t get the power until tstat completes circuit where as before it gets the power but doesn’t complete circuit to power motors until tstat closes circuit. I’m wondering if it’s for longevity of the valve or what reason is. Also do you have video showing the wiring including the C wire for most modern thermostats?
@cdenneen11 ай бұрын
Curious if you run the RED directory to Thermostat bypassing the Zone Valve on way up... How can you leverage this 24v to become the "common" wire for thermostat? Can you take the red thermostat wire and plug into R and jump to C (or vice versa)? Basically seems to allow the 2 wire thermostat wires to deal with the "missing common" issue it would seem.
@JerseyMikeHVAC11 ай бұрын
Powering the t-stat first generally works with many different types of zone valves, particularly if you have taco power heads and such. So going T-stat first is a more universal wiring approach that can accommodate variations there, and it's how most techs wire the stuff up anyway. Also with today's smart thermostats, powering them first can more likely help them work with full functionality. There may be a power related theory behind why going zone valve first might not be ideal, but I can't remember what it is. I had techs with 20+ years experience show me the ZV first method when I first started, so I don't think whatever that theory might be is very popular. As for a jumper between R and C, no. On power stealing thermostats you can use a resistor as a jumper between W and C and that typically works.
@cdenneen11 ай бұрын
Yeah since R-W isn’t closed until calling now sure how C would play into that. I’m just trying to figure out another way to leverage 2 wire tstat wire missing a C without need for something like Fast-stat common maker kit.
@vikingstigr11 ай бұрын
Ok but what if you just bought a Watts Tekmar that has the transformer built in? As far as I can see, it looks like the Tekmar takes care of the details and all you need to do is wire as noted in the diagrams. So both reds to motor, and each yellow to the end switch. I'm just at the finishing steps and can't see any other way to do it.
@JerseyMikeHVAC11 ай бұрын
Yes wire as the diagrams in the Tekmar indicate. But yellows are your motor. Reds are the end switch.
@vikingstigr11 ай бұрын
@JerseyMikeHVAC yup, I figured that part out. Get this: turns out the former homeowner crossed zone 1 and zone 2 so the supply lines were fighting each other. How they had 3 zones working when we bought the joint, I'll never understand. Also had to replace the transformer. The Tekmar works great. I'll be uncrossing those lines tmw. I want to have a chat with the monkey that did that.... ugh.
@ezramamiye55222 ай бұрын
Your good
@joshuatorres5542 Жыл бұрын
How can i join blue collar academy
@JerseyMikeHVAC Жыл бұрын
Send me an email notifying me of your interest and I will keep you updated as the course develops and becomes ready. BlueCollarAcademyHVAC@gmail.com
@roqueherrera8471Ай бұрын
@@JerseyMikeHVACme too?
@WilliamNicholsLC10 ай бұрын
I'm signing up..
@nayemhossain4283 Жыл бұрын
Hai, I am in New York, people needs help for tankless combi boiler ,my request to you ,if possible, please make something about combi boiler. Thanks for your help .