Hello, thank you for taking the time to share your feedback. We're happy to hear it was helpful for you! Be sure to subscribe to the channel for more content like this, and join us for our #McMcLive streams each month!
@luckysworld10686 жыл бұрын
Thank you for such a great explanation.
@mcnaughtonmckay6 жыл бұрын
Hi Santosh, It's great to hear that the video was helpful to you. Thank you for your feedback!
@pradeepyadav-kc3vf5 жыл бұрын
Can you explain me too.
@electricaluserstech.19892 жыл бұрын
Clear video, excellent.
@mcnaughtonmckay2 жыл бұрын
Thank you for the feedback! We hope it was helpful. Be sure to subscribe for more content like this.
@raymond685833 жыл бұрын
Excellent video very good
@mcnaughtonmckay3 жыл бұрын
Hi Raymond, Thanks for watching and sharing your feedback with us! We're glad to hear this video was helpful. Join us live on Wednesdays at noon EST for real-time presentations and demos from our specialists!
@teole73694 жыл бұрын
Tks for video. I have a question, can you help me? Is there a way to get all the data from the Powerflex 525 over Ethernet without an Allen-Bradley software or get data (parameter:basic display) from Connect Components Workbench?
@mcnaughtonmckay4 жыл бұрын
Hello, Yes, you can get this data from Connected Components Workbench over Ethernet but you cannot do this without Allen Bradley software. If you have further questions or concerns, please reach out to your local Rockwell Automation distributor.
@xxdankmemelordexx998 Жыл бұрын
Hello, will this program work with a PowerFlex 4M drive? It has a RS485 port
@mcnaughtonmckay Жыл бұрын
Hello, Yes, PowerFlex 4M drives can be programmed with CCW. Once in CCW, create a new project and name it respectively. Then, under the Add device selection screen click the Drives drop-down menu. The PowerFlex 4M drive will appear under the “PowerFlex 4-Class” folder. If you have further questions or concerns, please reach out to your local Rockwell Automation distributor for personalized support.
@TheRobertChannel Жыл бұрын
This will not work in multi-drive mode that are utilizing 5 devices on one node. Is there way a to pull parameters off devicenet, using the scanner module in CCW or do you have to use driveexcutive with RSnetworx
@mcnaughtonmckay Жыл бұрын
Sorry for the delayed response! Both CCW and DriveExecutive can be used to connect to the drive over DeviceNet if you are using a 22-COMM-D or 25-COMM-D adapter. We recommend using CCW as it is an active software product from Rockwell Automation receiving new features + patches. Alternately, the PowerFlex 525 parameters can be backed up with a USB connection when the drive is unpowered. Refer to the PowerFlex 525 User Manual for more details: literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um001_-en-e.pdf If you have any additional questions, please reach out to your local Rockwell Automation distributor!
@farooq58393 жыл бұрын
I need driveexecutive setup file because Rockwell has discontinued this software, any help will be appreciated
@mcnaughtonmckay3 жыл бұрын
Hello, Please contact your local Rockwell Distributor to purchase DriveExecutive (catalog #: 9303-4DTE01ENE). Then you can download it from the following website: compatibility.rockwellautomation.com/Pages/home.aspx If you are local to one of our branches, we would be happy to assist you: www.mc-mc.com/locations
@martinmchugh19242 жыл бұрын
Is the .ccwsln the only file that's required as a backup? I also have a .ccwsuo in my folder, what is this for?
@mcnaughtonmckay2 жыл бұрын
Hi Martin, Here's some info that might be helpful: .ccwsln - CCW Project File - This is the file extension of the project that is saved. This contains all devices/trends in the Project Organizer when the project was saved. Note: This file cannot be opened unless it is located in the original directory it was created in. A user cannot transfer a .ccwsln out of the project folder and open it alone. The entire project folder must be sent with the .ccwsln file to be opened. .ccwsuo--This file keeps track of where all the pieces of the project are located. Bottom line - CCW creates them and it's best to leave them as they are. If you have further questions or concerns, we recommend reaching out to your local Rockwell Automation distributor for personalized support.
@martinmchugh19242 жыл бұрын
@@mcnaughtonmckay Thank you very much. I really appreciate that detailed response. I will consider the entire folder as 'the backup' and leave them intact when storing. 👍
@mcnaughtonmckay2 жыл бұрын
@@martinmchugh1924 Happy to help!
@viplavavhad70982 жыл бұрын
HI how to connect FC with ethernet cable please tell me i dont have seriel port converter
@mcnaughtonmckay2 жыл бұрын
Hello, we would need to create an ethernet driver in RSLinx, Please see the video below from Rockwell Automation: kzbin.info/www/bejne/d4HNeX1nob-parM Please contact your local Rockwell Automation distributor for further assistance.
@zidanelahcen Жыл бұрын
Hello sir , can i use this cable with powerflex 40
@mcnaughtonmckay Жыл бұрын
Hello, The 1203-USB can be used for PowerFlex 40 Drives. Instructions on how to connect to a DSI drive can be found on page 21 of the 1203-USB manual: literature.rockwellautomation.com/idc/groups/literature/documents/um/drives-um001_-en-p.pdf If you have further questions or concerns, please reach out to your local Rockwell Automation distributor.
@josegonzales59137 ай бұрын
Does this work for 753 powerflex?
@mcnaughtonmckay7 ай бұрын
Hello, The 1203-USB can be used for PowerFlex 753 Drives. Instructions on how to connect to a DPI drive can be found on page 11 of the 1203-USB manual: literature.rockwellautomation.com/idc/groups/literature/documents/um/drives-um001_-en-p.pdf If you have further questions or concerns, please reach out to your local Rockwell Automation distributor. Need help finding your local distributor? www.rockwellautomation.com/en-us/sales/partner-locator.html?sort=dist&type=Authorized+Distributor+Value-Add&type=Authorized+Distributor+Specialty
@airakawairashi45282 жыл бұрын
Hi I want to know why when I want to connect it said my device not supported
@mcnaughtonmckay2 жыл бұрын
Hi Aira, we recommend updating your driver using your device manager. View the full recommendation from Rockwell Automation: rockwellautomation.custhelp.com/app/answers/answer_view/a_id/601966/loc/en_US#__highlight If you have further questions or concerns, please reach out to your local Rockwell Automation distributor for personalized support.
@Disciple8889 ай бұрын
This did not work for me. Getting a file from and existing project into a new drive with default parameters doesn't work like this in the field.
@mcnaughtonmckay8 ай бұрын
Hello and thanks for reaching out! To best troubleshoot your question we would need a bit more information and suggest a conversation with our technical team, or that of your local distributor, who can speak with you on your specific setup. To contact us: www.mc-mc.com/AllLocations or to find your local Rockwell Automation Distributor use: partners.rockwellautomation.com/en-US/partner-locators/
@DSNCB9193 жыл бұрын
I can't do this in studio ?
@mcnaughtonmckay3 жыл бұрын
Hello, That is correct. This functionality is intended for CCW, not Studio 5000. If you want to learn more about the offerings mentioned here, please reach out to your local Rockwell Automation distributor for further information.
@DSNCB9193 жыл бұрын
@@mcnaughtonmckay through ccw if I connect to a local switch where all the powerflexes are connected can I pull the backup files that way instead of plugging into them.one by one
@mcnaughtonmckay3 жыл бұрын
@@DSNCB919 Yes, as long as you can see the drives in RSLinx through the switch, you should be able to access the backup files. We still suggest reaching out to your local Rockwell Automation distributor for support specific to your application if you have any concerns. locator.rockwellautomation.com/
@sujanthansubramaniam40244 ай бұрын
அமைதி நாடு என்பது எங்களுக்காக. Not for Russia or Gaza
@arunemaar11806 жыл бұрын
Thanks for the valuable video. Can you advise me. I'm facing some issues on POWERFLEX 523 drive. I can give command frequency for ex: 30hz. The drive showing that frequency but the output frequency is 0. The motor doesn't ON
@mcnaughtonmckay6 жыл бұрын
Hi Arun, Double check that your wiring exactly matches the diagrams shown on page 11 of the Quick Start Guide (literature.rockwellautomation.com/idc/groups/literature/documents/qs/520-qs001_-en-e.pdf). You can also check your digital ins under parameter 14, detailed on page 19 of the Quick Start Guide, and follow the Smart Start-Up guide which starts on page 21. If you need further assistance, please contact Rockwell Automation as these drives qualify for free support from Rockwell Technical Support.
@moose4553478ify4 жыл бұрын
Allen bradley does this when a leg is probly not got a good connection. Had a new line last week electricians left a leg loose