UT Angle Beam Calibration Using IIW Type 2

  Рет қаралды 14,958

john burke

john burke

Күн бұрын

Пікірлер: 11
@floydarmstrong8212
@floydarmstrong8212 Жыл бұрын
Please John make a DAC video and reiterate why we even need the DAC when doing ASME. I understand that we need to know how the indication acts at different depths. But I’m struggling with building them and also understanding why we would need it.
@samardhool5436
@samardhool5436 4 жыл бұрын
Impressed by you john
@arifbugga7186
@arifbugga7186 3 жыл бұрын
Please do calibration phase array straight beam for 0.14 inches to 0.06 inches using epoch 1000i
@jeremystatham5613
@jeremystatham5613 2 ай бұрын
The side drilled hole should show a depth of .600” at calibration, should it not?
@jamesthrower6415
@jamesthrower6415 3 ай бұрын
AWS on/off before calibration and after?
@professorgreen1215
@professorgreen1215 3 жыл бұрын
should you check your index point and your agle before calibrating? because if your agle change the pathway change and need to recal again. am i right?
@rubiselcuba
@rubiselcuba 3 жыл бұрын
Agree..
@erikgriffith3263
@erikgriffith3263 Жыл бұрын
Not really. This is the whole reason that they are radiused so you could cal a 70 degree wedge or a 45 on the same surface. The 0 degree hash is the center of the "circle"
@Gukworks
@Gukworks Жыл бұрын
This was a questuon on B cwi exam. Not sure if I got right:(
@ABLE4DUBKAY
@ABLE4DUBKAY 2 жыл бұрын
Why 2 and 4 inches? What is it reading at 2? Shouldn’t it be 4 and 9 inches?
@johnreid2691
@johnreid2691 Жыл бұрын
This is Type 2 block, it has 2 radiuses one at 2" and one at 4". The 4"-9" is Type 1 block
UT Angle Beam Calibration Using IIW Type 1
12:59
john burke
Рет қаралды 26 М.
Basic Angle Beam Calibrations
5:06
Holloway NDT & Engineering Inc.
Рет қаралды 18 М.
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
UT Lack Of Root Fusion Signal
5:27
john burke
Рет қаралды 7 М.
UT Weld Centerline Crack Signal
5:55
john burke
Рет қаралды 8 М.
UT Angle Beam Calibration Using Rompus Block
6:59
john burke
Рет қаралды 15 М.
UT Lack Of Sidewall Fusion Signal
5:55
john burke
Рет қаралды 15 М.
How to draw DAC Curve Ultrasonic Testing. CSWIP, NDT Level 2.
13:46
QHSE Concepts, Welding & NDT.
Рет қаралды 17 М.
Epoch 650 Manual Calibration
16:44
OrbitalNDT
Рет қаралды 10 М.
UT Angle Beam Calibration Using DSC Block
11:43
john burke
Рет қаралды 9 М.
UT Sound Beam Profile Using IOW Block 20dB Drop
12:13
john burke
Рет қаралды 10 М.
UT IIW Type I Block Caution and Comments
4:42
john burke
Рет қаралды 9 М.
UT Weld Porosity Signal
4:51
john burke
Рет қаралды 12 М.