DNO ain’t are going to wonder how a PILC service got into an outside box!!!!!!!!!
@tonywatson141224 күн бұрын
Your camera work is like your electrical work....!
@Chunkymunky845 күн бұрын
Fair fucks 2 ya i have done a few of theese before, if u know what you are out, u will be 100%, would be on a rubber insulated matt tho
@electricalsolutionse4ltd7005 күн бұрын
Thanks for the tip, when you know you know.
@TheYohtube19 күн бұрын
I would slip some grey off some 16mm tails and slide that on your conductors and identify with a pvc tape of correct colour. Bind up the 3 way split with some self amalgamating tape. Efixx did something similar in one of their videos...obviously gland the other end!
@farmersteve129Ай бұрын
Looks like that outgoing cable is more than 3m... but then I guess with the level of disregard you have for the rules or even basic safety I shouldn't expect you to get that bit right! As for the comment about snitches... if you don't like it - stop posting videos of cowboys in action!
@electricalsolutionse4ltd700Ай бұрын
Outgoing cable is SWA longer than 3meters, so whats the issue with that???
@_MinerАй бұрын
Should be fused down / additional fused switch / not relying on the DNO's fuse?
@davidreason8334Ай бұрын
@@_Miner there isnt even a dno fuse here 😬
@Dooguk16 күн бұрын
Cowboy. That earth clamp is not approved to be used on lead cables. Then again, nothing you have done here is approved. You are destined for an accident to yourself, or heaven forbid someone else.
@electricalsolutionse4ltd70016 күн бұрын
Thank you for watching and thank you for your input.
@Dooguk16 күн бұрын
@@electricalsolutionse4ltd700 Stop what you are doing.
@joeglabus7255Ай бұрын
Is this in Albania?😂😂😂
@electricalsolutionse4ltd700Ай бұрын
Wouldn’t upset the Albanians. They ain’t people to be messed with. 😂
@joeglabus7255Ай бұрын
@@electricalsolutionse4ltd700 no fecks given unreal behaviour either way ex sse jointer been there done that 👍👍👍
@npr2002Ай бұрын
still kept the old 16mm tails to the isolator? swa cores are single insulated in that meter box? bonding clamp on the pilc? doing it all live? black core as the neutral??? what da fak
@electricalsolutionse4ltd700Ай бұрын
Nothing wrong with the 16mm will be updated a later date. All cores were sleeved identified also doubling up as double insulation. 1000s of Earth clamps are used on pilc up and down the country, seen 1000s literally. Also it’s not live because the service head fuse is out, technically your wrong about everything 😂😂😂😂😂
@electricalsolutionse4ltd700Ай бұрын
But thank you for your input. Appreciate your comments.
@izoolsАй бұрын
@@electricalsolutionse4ltd700 just because some other idiots have used the wrong type of earth clamp, which result in a worsening connection over type and damage to the service cable, doesn't mean its acceptable. If you saw loads of idiots in a rough suburb drink driving would you say that's fine too "Because everyone else is doing it"?
@electricalsolutionse4ltd700Ай бұрын
@@izoolsthank you for your input appreciate your comments.
@peteb3365Ай бұрын
are you approved for fiddling about with the suppliers infrastructure? if you are you sure dont show it in your working practices. relying on disposable nitrile gloves for safety? yes ok better than nothing but ffs... this is your life btw we talking about, your the one who could get a shick, and full on supplies short circuit will give enough to vapourise a human, look at your Zs to prove it...
@electricalsolutionse4ltd700Ай бұрын
Appreciate your comments, can’t argue with you. It’s quite refreshing to see men concerned for other men. I will explain in another video further why I made this video and more context around it.
@peteb3365Ай бұрын
@@electricalsolutionse4ltd700 cant argue about that, it is just concern as the current involved is serious, i know we all do dangerous things, i done plenty! a lot of the working practices rules are crap, end of day use your brain and judge for yourself. i been on end of a 415v short circuit, not pretty and not due to me!
@peteb3365Ай бұрын
@@electricalsolutionse4ltd700 think this is fair, its not fair when sparks complain because your cable layout is a little bit messy, they so bloody anal most of the time. so what if couple wires swap over, main thing is your not endangering yourself for want of a bit of education.
@electricalsolutionse4ltd700Ай бұрын
Thank you for your comments, and very good points highlighted.
@davidreason8334Ай бұрын
@@electricalsolutionse4ltd700 You are going to kill yours self or more to the point someone else DNO should of done this work they would of installed a fuse at same time