Generator Automatic voltage regulator(AVR) pathi oru video podunga bro.
@selvarajpalanivel75222 жыл бұрын
Sir வணக்கம் 1 hp Singer phrase meter with vfd control யுடன் கிடைக்குமா? நல்ல brand எது என்ன விலை இருக்கும்
@vpag98493 жыл бұрын
THANKS FOR EXPLANATION
@veeraragavan21532 жыл бұрын
Bro moter was struck then display current motor rpm or fixed rpm was displayed
@evanz5984 Жыл бұрын
Sir power consumption in industry decrease pana enna pannanum solluga sir... Na new job poirukean manager power consumption kami pana sollraga
@vkgovindaswamy24003 жыл бұрын
Can I get vfd for 5hp.singale.phase electric motor
@manikandan-py8tm3 жыл бұрын
Bro your video very useful
@prakash-pl3nh3 жыл бұрын
Bro, Ac to dc convater la Ac voltage 440V input , output dc voltage evlo set pannu vaing ka bro
@vengatessan9443 жыл бұрын
Hi sir i am working oman.i have vfd.ABB company 24 v. Now not working.some error .Come sir.A2 16 .MD VFD comm Error.what problem .Pls answer me sir
@mathsproblemsolver43953 жыл бұрын
Super explanation
@ganapathyganapathy917 Жыл бұрын
Sari ok, frequency increase panna Motor oda Speed increase aaguthu ok( as Per formula N=120F/P). Indha Motor oda Speed increase Pandrom En, Edhukku, adhoda use enna?? Adha pathi Theliva oru video podunga
@suresh.msuresh.m52594 жыл бұрын
Singal pase low volt irukku sir anakku vft 2h motar ranpannanum India sollunga sir acreegalcher
@muthukumar0029 Жыл бұрын
Sir doute motor name plate detail la pathan (allowable runing up time 100% un: 12s ,80% un:22s) poriyalla
@keerthishan73654 жыл бұрын
Bro pls give clear definition and parameters setting video of atv310 VFD and lmx32ad servo drive Schindler electric
@karthikrasu8580 Жыл бұрын
Sir abb vfd auto remote on off 0 to 20 ma on off video given sir
@sankarsubramani46152 жыл бұрын
Please explain about V/f method ,scalar, DTC
@Dineshnathan843 жыл бұрын
Bro, what is the operating temperature?
@vaishnavisrinivasan94295 жыл бұрын
Hi.. Video is very nice & explained well... VFD is commonly for Pumps & Motors only ? or it can be used for other loads like Industrial heaters / Ovens etc..
@manikandan-py8tm3 жыл бұрын
Can u explain ESP
@sheropavi84735 жыл бұрын
Sir submersible pump abbacs550, use panrom,, three phase la perfect a run aaguthu,, two phase la water flow low a iruku, frequency 36mela pogamatenguthu,550v iruku,,, nanga use paneathu direct current,,, solar illa, direct three phase agriculture current, ,,two phase la niraya water flow aga vali sollunga,,, kvr i drive la connect panna mudiyuma
@athish67163 жыл бұрын
Unga drive ACS550 la 3 phase rectifier iruku neenga 3 phase voltage kudukum pothu unga DC voltagela ripples or oscillation romba kamiya irukum so motor full speedla oodum, neenga 2 phase kudutha DC voltagela fluctuation irukum so DC under voltage controller motor speedah limit panidum so practically not possible..1 phase conduct panalaina other 2 phases ku load adigam aidum so unga rectifier damage agavum chance iruku so it is limited in drive... input phase loss illana DC ripple faultla drive trip aaga chance iruku.. mostly in any VFD make it would be same.
To avoid the ripples and fluctuations in DC voltage. Simple ah sona chopper will regulate the DC voltage and give constant voltage to the inverter
@athish67163 жыл бұрын
To avoid DC overvoltage the choppers are used, while decelerating the motor speed with very shorter ramp down time or while the load is driving the motor more than the set speed (synchronous speed) then the DC bus voltage would increase and the voltage would reach the over voltage fault limit or it may damage the component so brake chopper is used with the brake resistor to dissipate the extra DC energy as heat to maintain the DC voltage within the fault limit.
@namasthethalir4 жыл бұрын
SIR PLEASE DO ONE VIDEO FOR SERVO DRIVE AND DC MOTOR SSD
@vinothn56783 жыл бұрын
If choke not used in output of vfd which creates any problems?
@athish67163 жыл бұрын
The choke is used for many reasons like compensating the cable capacitance, to increase the dv/dt etc.., in simple words it avoids the voltage spike incase of longer cable length for example more than 300 meters in ACS800-01,04 drives, the longer cable would have higher cable capacitance and the high frequency could cause voltage reflection at motor terminals due to the cable capacitance and inductance which could damage the motor insulation, also other way around for the motors with lower cable length also sometimes need choke to limit the voltage rise time to avoid damaging windings based on motor manufacturer specification, voltage rise time above 0.3 micro second would be ok for any form wound motors.
@c.mchannel27954 жыл бұрын
sir E-03 what complint
@baluelectric3 жыл бұрын
Good well explained.I feel your speaking is fast.pl. be slow while explaining. Will helpful
@amrmotors89175 жыл бұрын
Ji,good morning, one dout 220 v power a 110v a mathamudiyuma.
@MATHIVANAN23054 жыл бұрын
Vfd not possible, you have to buy transformer step down the power input 220v output 110 ....follow this link kzbin.info/www/bejne/baLaanaJiMtphbc
@SATHISHKUMAR-mo6ul5 жыл бұрын
nitrogen injection fire protection system full video upload pls sir
@poopathiraja49254 жыл бұрын
Nanpaa intha model drivela on panna udane temperature high problem varuthu ithuku enna remedy pls sollunga nanpaa
@shakthisaravanan264 жыл бұрын
Check the thermistor of vfd which is placed inside the vfd
@athish67163 жыл бұрын
There is an NTC which measures the IGBT heat sink temperature... may be NTC faulty illana temp measurement circuit faulty
@buragaprasadbabu92265 жыл бұрын
Super gee
@Haripriyan2195 жыл бұрын
How to increase or decrease frequency
@sathishravi3845 жыл бұрын
Plc la minimum 20hz apply panni trail edukalam
@MATHIVANAN23054 жыл бұрын
Download manual from internet as follow you using current vfd driver model . Set the parameter setting for increase or decrease can select points
@mantupandit27055 жыл бұрын
Contactor patri sollunga
@jaganprasaad82178 ай бұрын
Good
@nktrendings8164 жыл бұрын
Super BRO
@josephprakash96824 жыл бұрын
Soft starters pathi video podunga nanba, thank you.
@shakthisaravanan264 жыл бұрын
Vfd and soft starter both are same bro. Vfd use pani speed vary panalam. But soft starter only constant speed but smooth starting ivlodhan bro soft starter
@josephprakash96824 жыл бұрын
@@shakthisaravanan26 thank you bro.
@sridharypm89435 жыл бұрын
Vfd not working auto mode. Hand mode only running. What happens. Pls tel me. It a very urgent.
@jkj14594 жыл бұрын
1) REMOTE SELECTION NOT ACTIVE OR NOT ENABLED , 2) 4- 20ma ANALOG INPUT MAY BE OPEN .
Single phase input and three phase output VFD சொல்லுங்க நண்பா
@Sivaraja4064 жыл бұрын
Emrosn
@athish67163 жыл бұрын
ACS310, ACS355 ABB
@raavanaking53074 жыл бұрын
What propose bro
@dhayanithe6164 жыл бұрын
Where is the practical section ??? That's important
@murugeshk43855 жыл бұрын
Bro why we are using VFD for control the speed of induction motor......... other drivers is also there what is the reason bro.
@IshakKhangulam4 жыл бұрын
Economy
@srirenukarajasrirenukaraja52664 жыл бұрын
Vfd ethuku use Pandoram athan uses
@kaviarasan66373 жыл бұрын
Where is the practical explanation, can u explanation driver circuits,commutation circuit ,control circuit for igbt
@praveenkumarlk85274 жыл бұрын
dc bus la high voltage varuthu,athu why.??????
@athish67163 жыл бұрын
Input AC voltageah diode or thyristor rectifieroda rectification factor kuda multiply panina ungaluku DC voltage kedaikum which 1.35 times of the applied AC voltage eg.. 400*1.35 = 540V DC
@praveenkumarlk85273 жыл бұрын
@@athish6716 oh okeyy thank you so much , understand 👍👍
@tamilyougo32855 жыл бұрын
Practical season ah pakalam nu sonninga practical season enga?
@senthilnathanshanmugasundr58705 жыл бұрын
Bro, This video is very useful for me. But I have a small doubt, for example, the motor is fed from VFD and VFD is fed from SWGR. THD value will be maintained in SWGR as per IEC. If THD value is exceeded, how to recover this? can we modify the change in VFD without replacement?
@lakshmikandhan91265 жыл бұрын
We can use 12 pulse bridge rectifier for reduction total harmonic distortion...we have maintained phase angle 30 degree for harmonic reduction...so we have to use converter transformer( converter duty transformer) it have one primary winding and two secondary windings...this is one of the important method for maintain harmonic
@Techdoct5 жыл бұрын
Yes whenever the input cycle increases atomatically hormanic will decrease
@sunilmanohar77985 жыл бұрын
Danfuss vld micro drive fc 51 external pot and rev fwd sollunga pls
@chellapandip67742 жыл бұрын
என்னிடம் மூன்று டிரைவ் இருக்கு சர்விஸ் பன்னி தருவிங்கெ லா
@manikandans62975 жыл бұрын
Brother. frequency etha depend panni varried aaguthu . Ex .: AHU starter. Vfd
@athish67163 жыл бұрын
Frequency is based on motor speed reference
@nandhakumarshanmugam1585 жыл бұрын
How to increase vfd starting torque, how to put the settings
@athish67163 жыл бұрын
If you take ABB VFD it has DTC Direct Torque Control which will take care of the torque demand of the application. or any VFD does produce the torque using the motor slip (load angle) margin by adjusting the stator voltage and frequency.