Viega PureFlow PEX vs. Cold Expansion

  Рет қаралды 14,380

Viega LLC

Viega LLC

5 жыл бұрын

A leading competitor falsely claims that its PEX-a cold expansion fittings deliver a 25% greater flow. We performed a demonstration to show what the actual performance difference, if any, is between these two variations of PEX systems in a scenario designed to exaggerate the fitting performance.
These tests show the difference in flow performance between Viega’s PureFlow system and cold expansion systems is unnoticeable in everyday use. Additionally, it is often the fixture at the point of use that is most restrictive in residential plumbing, not the piping components behind the wall. Considering this, why choose a PEX system that has lower material ratings like the 5106 cold expansion that also causes additional wait time? Go with the Viega PureFlow system which maintains the industry’s highest ratings, allows for immediate pressurization and a 25-year warranty.
Join our community and share your Viega Story:
Facebook: / viegallc
Instagram: / viegallc
TikTok: www.tiktok.com/@viegapress?_t...
LinkedIn: / viega-llc
Blog: info.viega.us/blog

Пікірлер: 41
@JonathonNeville
@JonathonNeville Жыл бұрын
Viega, can you do this test where the line goes to a bathroom and then a kitchen and then upstairs to another bathroom and kitchen, and open multiple faucets? Quicker and cheaper than doing the full test, can you reason thru whether in that context people would notice a difference?
@teeg3275
@teeg3275 Жыл бұрын
I love my expansion pex it’s always a good day throwin up some pex A shit use pex A with B fittings all the time. Never use viega pex or fittings but honestly look the same in size
@willrogersplumbing4053
@willrogersplumbing4053 3 жыл бұрын
I would agree with Viega-the faucets, stops, supply lines etc are where you will notice the most difference. Trunk lines/main feeds can be sized and installed in a way to offset any differences between a cold expansion and crimp flow rates. I wish Viega was more common in my area. I use the F1807 system most and I have never had an issue in over 20 years. PEX B out performs most PEX A also in the real world. Never seen issues with PEX B, I have seen multiple issues with PEX A and PEX C. In defenses of cold expansion like F1960, the connection is solid and I have never seen or had an issue, the piping is another story issues all over the place....
@AltPlumbingSanMarcos
@AltPlumbingSanMarcos 3 жыл бұрын
Let's do a realistic test and fill at toilet and run the shower at the same time or turn on a hose bibb or run a washing machine. This is when the pressure drops due to volume issues.
@shawnd567
@shawnd567 4 жыл бұрын
Wow! The tub fill was very surprising! Nearly 4gpm with barely any noticable difference! I also thought the pex-a fittings would provide much better flow. Brass fittings for pex-b also have a larger diameter than the plastic ones. Hey could you run this test with 1/2 pex?
@shawnd567
@shawnd567 3 жыл бұрын
@phillip miller Wow! I didn't think it was that high.
@TheRealJackassJesse
@TheRealJackassJesse 3 жыл бұрын
Moen Posi-temp rough in valve has a max flow of 4-6gpm at 60 psi.... These tests are to show that in typical home usage the difference in negatable. I wouldn't doubt that Uponor Wirsbo fittings do have a 25% flow difference in full flow conditions.
@ziegle9876
@ziegle9876 Жыл бұрын
My tub fills with 15gpm....
@JonathonNeville
@JonathonNeville Жыл бұрын
You ask if the test can be run with 1/2 PEX. I thought this test was 1/2 inch PEX. ?
@patricklafontaine4313
@patricklafontaine4313 Жыл бұрын
Hi, I try to know the flow of my home main water line and could not find any test on that and its hard to evaluate since I need to evaluate the velocity and it depends on flow... I can find pressure drop but I need to know the flow before to install my sprinkler system. I wish not to cut the line just to check because if it have not enough of flow I ll do differently... My main line is pex 3/4 (7/8 OD) and my static pressure is about 64 psi. Do you have an idea about the max flow? If you can tell me the flow while keeping a 40 psi pressure it would be the best since the max flow could not be use as it would drop pressure to 0. Thanks!
@SL-uy7hc
@SL-uy7hc 3 жыл бұрын
The true test would be to test the flow rate when using a full port hose bib or boiler drain. The tub/shower/lav all went through valves and cartridges with integrated restrictive channels which render this test useless if it's truly meant to test flow rates of pipes and fittings. This test concluded that fixtures are restrictive.
@ScottAcy
@ScottAcy 3 жыл бұрын
Exactly!
@isabellavision
@isabellavision Жыл бұрын
No, this test acknowledged what is commonly known, that fixtures are restrictive, often by design, and concluded that the difference in flow rate in pex systems is negligible in real world use with those fixtures.
@mikejones5364
@mikejones5364 Жыл бұрын
Do you drink or shower out of your hose bib? They used fixtures people use daily.
@devanmanansingh2591
@devanmanansingh2591 Жыл бұрын
Let's say I have a 1" full port valve and 2 GPM flows through it and I have a 1/2" valve and 2 GPM flows through it. Which valve has more flow? Answer, they both are the same, 2 GPM. How? Physics. Velocity will increase in the valve or fittings with a smaller diameter to match. Another note: a cold expansion fitting is not full sized. The I.D. of the fitting is smaller than the I.D. of the tubing and is still being inserted into the tubing. Small difference of the I.D. between Viega pureflow fittings and a cold expansion fittings. That is why the differences are minimal.
@jeremytine
@jeremytine Жыл бұрын
except the real world may have multiple fixtures being fed by a single pex line/trunk being used simultaneously, at which point it may matter. Yes you could upsize the line as well, but then you will waste more hot water flushing the line.
@alankwellsmsmba
@alankwellsmsmba 2 жыл бұрын
using a manifold with pex straight runs to each fixture resolves all issues. Just need to keep the manifold close to the water heater.
@mikejones5364
@mikejones5364 Жыл бұрын
That's silly. Space them manifolds out for maximum flow.
@SuperVeeZee
@SuperVeeZee 2 жыл бұрын
This test is not designed to exaggerate fitting performance. Quite the opposite. It's designed to mask it. Household water fixtures are flow-restricted. Showerheads are commonly restricted to 1.75GPM. What this test shows is that, in all of the tested systems, the fixture was the most restrictive part, not the pipe. If you want a real show of flow rate in one piping system vs. the other, remove the fixture and shower valve. Go to a full-port valve at the end of the line. You then remove the flow-restricted fixture, and you are testing only the pipe and fittings.
@jbarizonaa
@jbarizonaa Жыл бұрын
Tub spigot was full port or almost,
@SuperVeeZee
@SuperVeeZee Жыл бұрын
@@jbarizonaa That's true of the spout itself. But the cartridges that feed that valve likely are not. At every fixture, there is a limiting factor that is NOT the pipe and fittings. That's the point. What the test shows is that end-user experience is not really effected. That much is true. But it doesn't really refute the claim that expandable pex fittings provide more flow. It's a simple math game at the end of the day. The pipe is SDR9 CTS on both sides. If the fitting on the expansion side is the same ID of the pipe, and the fitting on the crimp side is a smaller ID than the pipe, the expansion side will have a higher maximum flow, all else being equal.
@danielsaucedo8098
@danielsaucedo8098 3 жыл бұрын
what size pex was this test preformed with?
@MisterRay11
@MisterRay11 3 жыл бұрын
1/2”
@RRA556
@RRA556 4 жыл бұрын
I wonder what the difference would be if you were to run all three fixtures at the same time.
@ziegle9876
@ziegle9876 Жыл бұрын
Because the problem is with the debit from the Clinton kitchen faucet and the Obama shower head, no the pipe. Thus this test is non-representative.
@blitz8619
@blitz8619 2 жыл бұрын
This isnt truly an accurate test since only 1 fixture is being tested at a time. In a normal household there are couple faucets running, like a shower, washing machine, toilet. A better test was to have all 3 on.
@jbarizonaa
@jbarizonaa Жыл бұрын
Right now Uponor has two class action suits pending, because there pex is falling apart after a few years, and it leaches chemicals in the water , don't believe me look it up yourself, I am very happy with my Viega no problems, plenty of water flow,
@SuperVeeZee
@SuperVeeZee Жыл бұрын
What's the second suit about? I'm aware of one suit regarding their color-coating process. They were basically over-cooking the pipe to apply the coating, and, over time, exposure to hot water would break it down. I had several people come in with hot-side lines that were orange with flaking coating. They've since switched to uncoated clear pipe with colored lettering.
@JtotheRizzo
@JtotheRizzo Жыл бұрын
This test is VERY MISLEADING! The difference in flow rate drastically changes when multiple fixtures are running at the same time. Example: if I am doing dishes only, flow rate is great at my kitchen sink faucet. Once my kid gets in the bath tub, it's a noticeable reduction. On top of that, once my washing machine starts running, my kitchen sink water pressure reduces down to almost a trickle. I'm sure I can speak for almost everyone by saying, "Viega, we dare you to redo this test with 3 or more fixtures running simultaneously." They'll never do it because they know the truth.
@CJINW
@CJINW 8 ай бұрын
Cannot trust any data with someone that has a computer voice.
@brl5755
@brl5755 2 жыл бұрын
This test stinks. Plumb a fake home-style layout with larger trunk and smaller legs and retest while filling more than one fixture at a time. My family doesn't plan out or even consider simultaneous water usage while using water, neither should this test.
PEX A vs PEX B: Pros and Cons 🤔
8:54
Williams Plumbing & Heating
Рет қаралды 1 МЛН
PEX Manifold System - Pros and Cons + Tour
12:01
Matt Risinger
Рет қаралды 1,3 МЛН
路飞太过分了,自己游泳。#海贼王#路飞
00:28
路飞与唐舞桐
Рет қаралды 39 МЛН
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 29 МЛН
Inside Out 2: Who is the strongest? Joy vs Envy vs Anger #shorts #animation
00:22
PEX-A vs PEX-B - What's the Difference? Which Should You Use?
9:23
Roger Wakefield Plumbing Education
Рет қаралды 740 М.
Pex A vs Pex B - What's The Difference?
15:22
HouseImprovements
Рет қаралды 155 М.
UPONOR ProPEX, The Future of Plumbing (COMPLETE GUIDE) | GOT2LEARN
10:03
What's the BEST Plumbing System
11:45
Matt Risinger
Рет қаралды 549 М.
Which is Better PEX A or PEX B | Pressure Test
8:18
Roger Wakefield Plumbing Education
Рет қаралды 192 М.
When PEX goes horribly wrong
10:55
My Fortress Construction
Рет қаралды 718 М.
Can we blow off these PEX fittings?  Sharkbite vs Viega vs Uponor
16:04
Matt Risinger
Рет қаралды 1,4 МЛН
PEX Pipe - 5 Connection Options
36:08
Matt Risinger
Рет қаралды 208 М.
Best Sharkbite Pex Fitting? PEX Crimping Tool Comparison
27:49
Homestead Bandwagon
Рет қаралды 23 М.
Это iPhone 16
0:52
Wylsacom
Рет қаралды 1,2 МЛН
Xiaomi SU-7 Max 2024 - Самый быстрый мобильник
32:11
Клубный сервис
Рет қаралды 554 М.
Looks very comfortable. #leddisplay #ledscreen #ledwall #eagerled
0:19
LED Screen Factory-EagerLED
Рет қаралды 13 МЛН