VRV3 | Basic step for unified AC communications troubleshooting | error U4

  Рет қаралды 10,074

Bon Mj

Bon Mj

Күн бұрын

Пікірлер: 67
@HajaShah
@HajaShah 8 ай бұрын
Boss ur knowledge for VRV aircon is awesome👍🏽👍🏽
@BonMj
@BonMj 8 ай бұрын
Thanks 👍
@alexandergorelov2515
@alexandergorelov2515 Жыл бұрын
Thanks a lot for this video! Very interesting. Service checker is really recommend for maintenance!
@BonMj
@BonMj Жыл бұрын
You are welcome!
@keovongvilaykeo4799
@keovongvilaykeo4799 8 ай бұрын
Great troubleshooting thanks 🙏 you for sharing 😊
@BonMj
@BonMj 8 ай бұрын
Thanks for watching!
@mallkomoha6823
@mallkomoha6823 Жыл бұрын
Thanks for sharing Bon
@BonMj
@BonMj Жыл бұрын
You are so welcome
@reynoldroncesvalles8293
@reynoldroncesvalles8293 Жыл бұрын
Good day, sir, Bon,pls, need, resetting warless control of vrf, pls shares actual videos,, thanks 🙏🙏🙏
@reynoldroncesvalles8293
@reynoldroncesvalles8293 Жыл бұрын
Panasonic warless, control, I need, sir,Bon,,,
@salimagwan9672
@salimagwan9672 Жыл бұрын
Nice job sir👍
@BonMj
@BonMj Жыл бұрын
Thanks 👍
@phathuynh4325
@phathuynh4325 Жыл бұрын
Nice job Sir
@BonMj
@BonMj Жыл бұрын
Thanks
@mohamadafravi1160
@mohamadafravi1160 Жыл бұрын
Hi 👋 my friend. So useful video. 👌
@BonMj
@BonMj Жыл бұрын
Thanks
@mohamadafravi1160
@mohamadafravi1160 Жыл бұрын
Please make a video of the branch controller
@BonMj
@BonMj Жыл бұрын
@@mohamadafravi1160👍
@peramaraj2763
@peramaraj2763 Жыл бұрын
Thanks for your update video sir
@BonMj
@BonMj Жыл бұрын
Always welcome
@thanaung3154
@thanaung3154 Жыл бұрын
thanks a lot for Sharing video 🙏🙏🙏
@BonMj
@BonMj Жыл бұрын
Most welcome
@bunyamingul9607
@bunyamingul9607 Жыл бұрын
👍👍
@BonMj
@BonMj Жыл бұрын
Thanks
@mojeshmeenuga8432
@mojeshmeenuga8432 Жыл бұрын
Thanks sir😊
@BonMj
@BonMj Жыл бұрын
Most welcome
@thanwin3920
@thanwin3920 Жыл бұрын
Thanks Sir
@BonMj
@BonMj Жыл бұрын
Welcome
@Marcoguima45
@Marcoguima45 Жыл бұрын
Good Job 😎🇧🇷
@BonMj
@BonMj Жыл бұрын
Thanks
@sv6k0a39
@sv6k0a39 Жыл бұрын
Is that "Gas Temperature" the suction pipe temperature reading? Or is it the refrigerant saturated temp from a pressure transducer?
@janshaw5472
@janshaw5472 Жыл бұрын
Good😅 job 👏
@BonMj
@BonMj Жыл бұрын
谢谢
@karaors8970
@karaors8970 Жыл бұрын
👍🧿👋
@BonMj
@BonMj Жыл бұрын
Thanks
@monosolution5424
@monosolution5424 Жыл бұрын
Hello teacher Bon Mj how are you? May you help i want to ask you one question? Now I am install VRV IV System and owner house have Electricity three phase 100 ampere.And The machines Master 40A slave 1=30A slave 2 =30A it is enough or not? Thank you in advance.
@EastWestACServices
@EastWestACServices 9 ай бұрын
Great video can I purchase a service checker from Singapore!
@BonMj
@BonMj 9 ай бұрын
From Daikin
@abarrasheed3098
@abarrasheed3098 Жыл бұрын
Sir when replacing main PCB in master unit vrv 4 how to set dip switch settings please reply thank you
@kahungcheung-k8t
@kahungcheung-k8t Жыл бұрын
Hi sir, if one indoor fault ‘C4’ , all system will fault ‘u4’/‘u9’?
@BonMj
@BonMj Жыл бұрын
No
@AK-yu3cu
@AK-yu3cu Жыл бұрын
Please share link for testing & commissioning Daikin VRV IV & X models
@BonMj
@BonMj Жыл бұрын
kzbin.info/www/bejne/iJ3IdKmropKVe7M
@kahungcheung-k8t
@kahungcheung-k8t Жыл бұрын
Hi sir, my indoor all fault u4(outdoor model RXYQ12PAY19) How to check indoor and outdoor electronic board broken?
@BonMj
@BonMj Жыл бұрын
Outdoor Pcb power light ok?
@kahungcheung-k8t
@kahungcheung-k8t Жыл бұрын
@@BonMj power light is ok
@peramaraj2763
@peramaraj2763 Жыл бұрын
I have a doubt sir VRV-3 got error code U4 we check and found control PCB fuse burned after replace the fuse than test run running amps 8 to 9 reached again fuse burned we checked incoming voltage is normal so what is the issue ?
@BonMj
@BonMj Жыл бұрын
Check power supply,voltage ok? Check fan motor and compressor
@peramaraj2763
@peramaraj2763 Жыл бұрын
@@BonMj thanks for your update sir
@Steven-vy7en
@Steven-vy7en Жыл бұрын
hi sir ,can i know how to check vrv 3 6hp compressor cannot run at high speed and no show error code .tq
@BonMj
@BonMj Жыл бұрын
Check indoor and outdoor thermistor reading and pcb
@Steven-vy7en
@Steven-vy7en Жыл бұрын
@@BonMj ok tqvm👍👍👍
@Steven-vy7en
@Steven-vy7en Жыл бұрын
@@BonMj hi sir, i had check the indoor & outdoor thermistor reading no problem but when starting compressor running high site 350psi & low site 60psi amp 13.xx the compressor will run low speed high site 250psi low site 110psi amp 6.xx
@jairam425
@jairam425 Жыл бұрын
Hi sir I'm ram, Form dubai In My working site samsung vrf digital inverter, duct-table FCU have a problem since 4 months, vrf outdoor have 3 indoor units connect The problem is 3 FCU's fan moter speed not controlling in thermostat always running high speed in a month 1 and 2 days fan speed controling , we connect laptop tyred to control fan speed 1) we did three time programming 2)we changed fan mothers 3)we changed fan capacitor 4) we changed FCU pcb 5) we checked communication cable its proper condition 6) we changed fan control 7) we changed outdoor main pcb 8) we checked 3phase power with meger power normal condition Plz give a suggestion ( I don't now the vrf system FCU fan speed why some days controlling some days control maybe fault from outdoor sensors because some days working some days not working)
@BonMj
@BonMj Жыл бұрын
Any error
@jairam425
@jairam425 Жыл бұрын
@@BonMj No error sir and Today started other 2 apartment same problem facing (I note a point In UAE Since yesterday evening Too much humidity total Vrf units outdoors at night time sweating because of humidity) I can't understand
@peramaraj2763
@peramaraj2763 Жыл бұрын
I have a doubt sir city multi VRF error code :6600 M-Net address is 009 but remote appear 015 what is the cause of problem sir please explain to me
@BonMj
@BonMj Жыл бұрын
Do the system two Fcu using one remote?
@peramaraj2763
@peramaraj2763 Жыл бұрын
@@BonMj no sir one fcu and one remote sir
@arjunapeiris981
@arjunapeiris981 10 ай бұрын
What is your mail address sir
@BonMj
@BonMj 10 ай бұрын
bonmj81@gmail.com
@arjunapeiris981
@arjunapeiris981 10 ай бұрын
Thank you sir. My name is Arjuna peiris I will send masege for your mail.
@kahungcheung-k8t
@kahungcheung-k8t Жыл бұрын
Hi sir, if one indoor fault ‘C4’ , all system will fault ‘u4’/‘u9’?
@BonMj
@BonMj Жыл бұрын
No
@BonMj
@BonMj Жыл бұрын
If many Fcu in one system, normally U9 Fcu are ok, check other fcu
Daikin U4 Troubleshooting
24:37
Christopher Brown
Рет қаралды 1,3 М.
VRV4 | Emergency maintenance | error E2-01 L5-14 J5-01
13:29
Daikin VRV 3 Malfunction Diagnosis Using Outdoor PCB
12:32
Arista Air Conditioning Training Videos
Рет қаралды 11 М.
THAT DAIKIN U4 FAULT ! BUT DID YOU KNOW WHY ?
17:23
HVAC UK
Рет қаралды 47 М.