Was this old air compressor about to EXPLODE ??

  Рет қаралды 158,328

Gosforth Handyman

Gosforth Handyman

5 жыл бұрын

Old compressors can be dangerous. I've had my old Airmaster air compressor for many years. I was given it second hand and never knew the history. It was time for it to go a journey and in the name of science have a look at whether the tank was about to explode.
TOOLS & PRODUCTS I USE: gosforthhandyman.com/products...
NEWSLETTER: gosforthhandyman.com/newsletter
PATREON: / gosforthhandyman
SHOP: gosforthhandyman.com/shop/
EXTRA STUFF ON THE WEB: gosforthhandyman.com
INSTA: / gosforthhandyman
TWITTER: / gosforthandy
#Workshop #Compressor #AirTools

Пікірлер: 492
@billsixx
@billsixx 2 жыл бұрын
"HYD" refers to hydrostatic pressure testing. They fill the tank with water and pressurize it to 250 PSI. They use water so if the tank ruptures, there is no explosive release of pressure.
@aldaog9107
@aldaog9107 Жыл бұрын
Used to do this for a living. Built all sorts of tanks and I was lead inspector plug it and fill it.
@aldaog9107
@aldaog9107 Жыл бұрын
Only ever had one explode, it sent the plug over a football field length through the shop and out the sheet metal wall it went.
@markburckhard553
@markburckhard553 Жыл бұрын
Just like scuba tanks, they have t be "hydroed" on schedule
@rbrtcrowther
@rbrtcrowther 3 жыл бұрын
I had a good chat to the man who does the insurance inspection on our compressors at work... he used a thickness tester and a camera to check them out every year. The big one was made in the 60's . He said they will normally blow a pin hole in the tank when corrode badly and very rarely explode.. Only after people have tried to repair the tanks by welding up the pin holes and of patching in new steel and drain fittings do they generally become dangerous due to the heat from welding and the stresses caused by it..
@traubengott9783
@traubengott9783 Жыл бұрын
Thats true for the old massive tanks. New ones are thin sheet metal that will explode without much warning.
@thehutx
@thehutx Жыл бұрын
thats what inspection guy at work told me to
@RegulerShowTV
@RegulerShowTV Жыл бұрын
@@derektaylor2941So you’re saying don’t risk using an old compressor ?
@ColinWatters
@ColinWatters Жыл бұрын
This one exploded.. kzbin.info/www/bejne/jWOvk4d-m7ponLM
@Third_eyee
@Third_eyee Жыл бұрын
the guy on youtube that had his explode did so for the very reason you mentioned, it rusted out on the bottom, started leaking and he welded a patch over it, the air compressor ended up exploding..
@gwille4life
@gwille4life 11 ай бұрын
Functionally operates just as it should kzbin.infoUgkxiiMg_x4gIWeXMWfBnDdRnME4qJUAva4w holds pressure perfectly when not in use. Glad one of the other reviews pointed out that the bottom pressure release valve was open; thought it was defective at first.
@sburge1989
@sburge1989 5 жыл бұрын
I bought an old one, a Clark Tiger or something. It was £50. I probably spent about the same replacing valves and stuff. It vibrated so much when it was charging the tank it would roll across the floor. The wheels had fallen off so it achieved decent movement purely by vibration. I sold it for about 100, bought an electric nailer. Which has since broken. Now I use a hammer and nails.
@superiorbeing95
@superiorbeing95 Жыл бұрын
None of my tools break, largely because I don't use them very often😆
@donaldshimkus539
@donaldshimkus539 10 ай бұрын
Sounds like evolution in reverse, lol.
@steveforrester2217
@steveforrester2217 5 жыл бұрын
This one would have probably lasted longer than your new one! Quality of these things now, is very poor. I bet your new tank was not that thick. Thanks for your video. It was very interesting.
@oliversmith4518
@oliversmith4518 2 жыл бұрын
Black coating you called protective coating is really just mill scale. It’s iron oxide that bonds to the surface of hot rolled steel. It protects if from atmospheric corrosion.
@lockpickingbelfast
@lockpickingbelfast 5 жыл бұрын
Had you not got no cutting discs, hard work with the grinding disc you used to cut it open
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
Better sparks for the vid. You'll see I'm doing 45 degree grinding passes to try and thin the material a bit around the cut. 👍
@markharrisllb
@markharrisllb 3 жыл бұрын
@@GosforthHandyman Is it not dangerous to use grinding discs for cutting and cutting discs for grinding? I’m a complete novice and this is a genuine question not a criticism.
@davidquirk8097
@davidquirk8097 3 жыл бұрын
@@markharrisllb you certainly shouldn't use a cutting disc for grinding, the disc isn't designed to take the side loading. Cutting with a grinding disc is slow because your removing more metal than you need but no real reason why you shouldn't.
@vladisergeiev7278
@vladisergeiev7278 3 жыл бұрын
@@markharrisllb Exactly what David Quirk said. Cutting discs are thin and meant to remove as little metal as possible in order to make a cut. Grinding discs are thick and are used for material removal, as opposed to making cuts. The thin discs are prone to explosion if too much pressure parallel to the axis and can be very dangerous in that situation. Be careful in general.
@itsthemetho
@itsthemetho Жыл бұрын
I purchased a 2nd hand air compressor that was in "good condition" from an auction. I was shocked to find that it was 1/3 full of water. You just never know how the last owner treated it. I was able to pull it to bits, clean and inspect the tank visually and hydrostatic pressure test it. I was happy to keep using it. However during transport the water with iron particles contaminated the high pressure line from the compressor pump and the non-return valve would get dirty and not seal. I was able to clean these lines and fix the problem. However had I known that original state of it, there is no way I would have purchased it.
@trexmidnite
@trexmidnite Жыл бұрын
It probably last longer without regular draining as corrosion needs air and water
@lorchri14
@lorchri14 Жыл бұрын
Appreciate that you took the time to diagnose, film, and put it out to inform us. ** never weld a tank, they are heat treated after all welding is complete so the tank can "breath" like a lung with pressure changes.
@AM-jw1lo
@AM-jw1lo Жыл бұрын
Perhaps, i would think Hydrostatic test every few years would be a better way to operate.
@fredhinck9685
@fredhinck9685 4 ай бұрын
Doubt very much the heat treating is done after the wheels and motor and pump supports are " WELDED " on.
@lorchri14
@lorchri14 4 ай бұрын
@@fredhinck9685 Heat treatment is often applied to relieve any internal stresses within the metal caused by the welding process. Done after all attachments are welded.
@travelswithbilbo7526
@travelswithbilbo7526 5 жыл бұрын
I used a compressor and nail gun in a loft conversion once and forgot to turn it off after work. It started up at 2am and scared the shit out of the clients living there😂 don’t use it now after getting a Ryobi battery nailer
@jasonmoore3557
@jasonmoore3557 2 жыл бұрын
🤣
@New777World
@New777World 2 жыл бұрын
😂😆
@dashooting6595
@dashooting6595 4 ай бұрын
I can imagine that 🤣😂
@charleshealy341
@charleshealy341 3 жыл бұрын
I rebuild air compressors here in the mountains of Colorado. My preferred method is to take all of the fittings out of a pressure tank, and look inside it. Light it up from inside with a very small bulb that will fit into any one of the half inch or 3/4 inch holes. Then drop an assortment of bolts and nuts inside it, with a solvent like lacquer thinner or just about any other type of a solvent fluid. Rattle it around as long as you can stand it until your arms get sore, and then dump everything out, pull the hardware out with a magnet. Then the tank will look much cleaner inside, if there was any rust. Colorado is west of the hundredth Meridian in the US, so it is very dry here. Relative humidity is very low compared to the eastern part of the US. So rust as you see, in the British Isles, is simply non-existent here in the West. Lucky for us. And then if I really want to get carried away I will pour paint inside it, the best rust resistant oil resistant paint that I can find, and slosh it around to make sure all of the bottom of the tank is completely covered. Let it dry, run some air into it and leave one of the holes open, so that the air can get out, to help it dry quickly. Assemble everything, and you have an essentially brand new air tank.
@czechgop7631
@czechgop7631 Жыл бұрын
Though I have to add that it's still a good idea to have it pressure tested if your tank is more than ten or twenty years old.
@alexk6745
@alexk6745 Жыл бұрын
I was thinking do same thing. But thinking a bit I decided it doesn't worth it. You have many mistakes in your thinking. You can't clean all the rust from inside. No matter what you do the metal will have spots covered with rust. Did you see this guys was grinding and he still has had some dots covered with rust.If you paint over with some rust guard paint it ideally should soak till the metal through the rust to avoid further corrosion. That's unlikely to happen. So eventually it will continue to rust in some bad areas. The best you can do is put it in a cage run test to max possible pressure and then use regulator to reduce max pressure so that it does cut of earlier than the pressure you have tested. I've made decision to go cage route as cage needed anyway for the case if I get a faulty tank.
@superiorbeing95
@superiorbeing95 5 жыл бұрын
That corrosion on the top side of the tank obviously meant it was used in Australia at some point.
@KiboTennis
@KiboTennis 5 жыл бұрын
Superior Being why would that matter? The earth is flat. 😉
@superiorbeing95
@superiorbeing95 5 жыл бұрын
@@KiboTennis This might be proof that it isn't, surely, plus the water drains out of their sinks the wrong way round, but I guess the Kangaroo puppies would fall out their mum's pouch, so much contradicting evidence!
@johnkirkwood7606
@johnkirkwood7606 5 жыл бұрын
Kangaroos have joeys, not puppies!
@samuelfellows6923
@samuelfellows6923 5 жыл бұрын
Superior Being - 😆
@superiorbeing95
@superiorbeing95 5 жыл бұрын
@@samuelfellows6923 I realise now that that Kangaroo is carrying a Kangapotamoose calf, my bad!
@martinnightingale6033
@martinnightingale6033 3 жыл бұрын
Interesting video . My compressor is 20 years old . Must admit when not in use . The drain is left open . The motor and pump on yours has still got life . Both could have potentially been refurbished and built onto a new tank . Cool video
@abdulelkhatib2674
@abdulelkhatib2674 3 жыл бұрын
I don't see why compressor tanks don't have some kind of coating inside either aluminum or stainless. Or some kind of rubber to help extend the life.
@sklikizos
@sklikizos 5 ай бұрын
Water is a solvent, especially when it's full of atmospheric particles or debris suspended in your workshop air. Over enough compression cycles and repeated condensation, that layer would be eaten through no matter what, faster than you would imagine. Believe it or not aluminum would be even worse due to its reactivity. And while yes, that would lead to eventual tank compromise, what would happen first is that layer would break down into little chunks in particulate that would ruin your air tools paint, and anything else you're blowing the air at. It seems like an obvious and logical thing to do - but that's a hint somebody else already thought of it and there's a reason why it's not done.
@THECompressorGuru
@THECompressorGuru 3 жыл бұрын
I have been in the air compressor business since 1979 I wish people would realize that an air tank is actually stored energy! and it is so important to drain the tank regularly. and never buy a compressor that does not have a certification tag ( the welded 3x5 ") metal tag on the tank, this tank was a certified tank and still had great damage from neglect. good video. THE Compressor Guru
@peter4289
@peter4289 5 жыл бұрын
Good video but I have never seen anyone try and cut metal with a grinding disc like that.
@michaelstevens5177
@michaelstevens5177 3 жыл бұрын
Me neither
@emostorm7
@emostorm7 3 жыл бұрын
What i can to say
@brainisfullofnonsense8183
@brainisfullofnonsense8183 3 жыл бұрын
I cut metal all the time with a grinder, but I use a really thin diamond coated metal cutting blade from Lennox. That super-wide disk ground away about 6X as much metal as the blade I use. I also use gloves, goggles AND a face shield. Yes, that is two things to keep crap out of my eyes. I learned the hard way the value of a second level of protection for your eyes. Kind of like still using a condom even if she says that she is on the pill. Better safe than sorry.
@danelectro68
@danelectro68 3 жыл бұрын
Absolutely, talk about make work for yourself!!!! Probably took hours to cut that open!!
@policedog4030
@policedog4030 3 жыл бұрын
I believe that is leaded steel; similar to that used in automobile fuel tanks - it is non-sparking. OSHA in the US had a case they thought a leaking o-ring or seal let too much compressor oil into the tank and the oil mist ignited when the compressor heated up in normal operation. So a fuel type explosion, not just rusty tank. 30 weight motor oil not particularly flammable unless it is in an aerosol
@elgin7406
@elgin7406 4 жыл бұрын
I've got a Kellog American Compressor, the date on the ASME certification tag says 1940, shell thickness is 13/64inch. I use it nearly every day and keep her filled to 140psi at all times! I certainly don't stand next to it and watch it fill up though. It's kept in a side compartment of my shed, so hopefully the chip board and drywall will keep the shrapnel contained, should it ever let loose.
@slugore
@slugore 5 жыл бұрын
This definitely has me thinking about my compressor. It is at least 12 years old and has a broken wheel on it that I have been meaning to repair but maybe it isn’t even worth it. I didn’t even think that it would have a short life span.
@Dragonited
@Dragonited 5 жыл бұрын
You could have made a small forge of the tank if you're into that sort of things. Pask Makes did a forge pig to heat treat steel to make his own tools etc. The motor is also still usable to make other machinery.
@francisbriggs76
@francisbriggs76 2 жыл бұрын
I have a similar one from 1962! I have been watching some tube videos and have decided not to use it anymore though it still works fine. I have drained the tank often but very dry here,not much humidity just the water created from compressing the air. I think I will cut mine open as well.
@shannonjaensch3705
@shannonjaensch3705 Жыл бұрын
Just watched two vids on someone who's compressor exploded a week ago. The tank ripped apart like a bomb and the guy is lucky to be alive. Great vid and appreciate the advice and inspection tips.
@MrKentaroMotoPI
@MrKentaroMotoPI 11 ай бұрын
Nice tank 👍 Well designed and built. The welded seam is in great shape. This tank would likely fail via pinholes on the bottom centerline. Yes, horizontal tanks get a fair amount of rust on the top.
@36736fps
@36736fps 5 жыл бұрын
Thanks for the clarification that the fire extinguisher being tested was filled with water. But I think the tank the fire extinguisher was submerged in was open to the air and therefore not pressurized.
@peterhanson3962
@peterhanson3962 5 жыл бұрын
I worked for a company that used air compressors to operate gas/air pumps, and the compressors had to be serviced regularly ie change pressure valves,air filters etc and replaced every ten years.So you got good service from your old one, but definitely time for a new one.
@SeanBZA
@SeanBZA Жыл бұрын
Large ones in industrial plant I have seen them up to 60 years old and still in use. They get hydro tested every year during shutdown (regulations say every 5 years, but they are figuring as the plant is being shut down might as well do it as well) as to replace them will mean dismantling large chunks of buildings and removing plant and roof to get cranes in. Tossing after 10 years on a small one is possible, as the test after that time, and fixing it, probably is approaching the cost of a new one anyway. But on large units you will want those parts to last a long time, so regular service of the compressors, change oil regular and so on.
@Parafinn1970
@Parafinn1970 5 жыл бұрын
What is the make/model of the new compressor you bought - any recommendations?
@jonchilds1637
@jonchilds1637 Жыл бұрын
The one you have there is from an old range which has what we used to call a ‘T-pump’. That’s a pre-1990 machine and the pump will be mainly cast iron. Around ‘90-‘91 these gave way to a cheaper, lighter Italian-made (Fini) pump which was nowhere near as durable - especially the valve plate. A lot of the larger air receivers were made by Rednal Pneumatics in Shropshire and they were proper quality. The Rednal ones usually carried the name etc on the end. 50/60 litres was the transition between Rednal tanks and imported ones. If I remember right, petrol portables used Rednal tanks but electrics used imports - definitely lesser quality!!
@BackpackerCoach
@BackpackerCoach 3 жыл бұрын
I think i depends on how will you take care of it. If you put a water separator / dryer in right after the pump. It could last for a very long time. That is what I am planing on doing when I get my big compressor.
@jonkirkham9920
@jonkirkham9920 5 жыл бұрын
Andy, watched the video this morning and this afternoon when running up my 20 year old Axminster compressor a rusty pin hole blew out , no explosion just a lot of hissing, time for a new one I think
@andrewhigdon8346
@andrewhigdon8346 3 жыл бұрын
Wow What timing. Your very lucky.
@2mallyb
@2mallyb 3 жыл бұрын
@@andrewhigdon8346 * you're
@Sir.Fisher
@Sir.Fisher Жыл бұрын
Years of life left in that
@timpreece
@timpreece Жыл бұрын
Great video, very informative! If that's used at home, there's no regulation (other than the usual CE Marking for supply) that mandates any regular inspection. But if it's used in a workplace, and the volume x pressure is more than 250 Bar Litres (excluding the 24 Litre, 10 Bar "Hobby Compressors"), it would legally need a WSE (Written Scheme of Examination) under PSSR (Pressure Systems Safety Regulation):2000, which would dictate (certified by a "competent person", based on a risk assessment) what degree of inspection (typically ultrasonic thickness test for the receiver and a pressure test of the PRV and Gauges against a calibrated gauge). The receivers ("pressure vessels") are always supplied against a design code (should be stated on teh data plate!) which specifies the minimum design thickness, plus a corrosion allowance (EN 286-1 is typically 2mm + 0.5mm for steel, but older codes had a greater thickness). That one was probably the older BS 5169, possibly with 3mm + 0.75mm corrosion allowance. Life expectancy will depend on how often the condensate is drained from the receiver and often it's the compressor (especially if not regularly maintained) that limits the life... Modern industrial compressors tend to be coupled with an automatic timed or zero-loss drain, so you don't have to remember to do it manually.
@MdaMda-ky7zd
@MdaMda-ky7zd 5 жыл бұрын
lol, love it, that is heavier than I remember it being, that is getting old my friend, I know exactly how ot feels
@robertburgess9374
@robertburgess9374 4 жыл бұрын
All air receivers are prone to condensation inside, which causes rusting from the inside (which cannot be detected from the outside)... At the end of the day the water should be drained via a tap at the bottom, preferably with the cylinder still under pressure to blow out the water... It should then be left open until the compressor is next used. All cylinders should be visually checked on a regular basis (a cheap video camera can be used inside the tank), and pressure tested at least once every two years, using water (not air) and a boiler test pump to 2X (or better still 3X) the normal working pressure... Any weaknesses , or thin spots, will then show as water leaks - if you tried the same test using air the cylinder coud explode (as seen in another YT video, caught on security camera)... Compressed air has immense stored energy, whereas water is virtually impossible to compress. so doesn't store energy.. Having said that I have an old riveted cylinder, so at least pre WW2 - I know it has rusted through as it sits on a block of wood with a piece of rubber between - it blows off at about 50psi..... I've just bought a newer replacement, and will pressure test that before I use it.... The old cylinder will become a garden BBQ or fire-pit....
@shanesouthwood8413
@shanesouthwood8413 5 жыл бұрын
I have and use a 50+ year old 60 gallon 2-stage. I've had fittings fail, but never an issue with the tank or welded bungs.
@r1273m
@r1273m 5 жыл бұрын
That was very interesting, I asked a question on this very topic on KZbin as I have a compressor, probably similar age to yours, but I haven't used it for a few years due to these very concerns. I think in view of what you have demonstrated I will retire my compressor also. I suppose the worst thing that could have happened to you would be to cut it open and find it all nice and clean and shiny!!!
@DocScience2
@DocScience2 Жыл бұрын
one recommendation is to put the compressor outside in its own small building, so that no one goes near it when it is in use. . You can safely use it until it stops or self destructs.
@elianazz
@elianazz 7 ай бұрын
i have one of those mine was never checked and after i saw another one explode,,,, i wont be using it in the house again!
@Whiteboytripping
@Whiteboytripping 3 жыл бұрын
I used to use an old hot water heater for an air compressor tank.... Since then I’ve realized I’m not invincible.
@daviddaniels6263
@daviddaniels6263 5 жыл бұрын
Loved that intro video of you moving the compressor... was something a little different but keeping with the theme of your channel.
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
Cheers bud! 👊
@terrorfirma2764
@terrorfirma2764 5 жыл бұрын
Hyd probably means hydraulic. It was probably filled with fluid, and pressurised in the same way as scuba tanks are.
@cycleguy666
@cycleguy666 3 жыл бұрын
That made it a long time!! I had a compressor that was built in 1975. I scrapped it but kept the motor and pump. They bring good money!!
@seanjay886
@seanjay886 5 жыл бұрын
Hyd will be with water. It’s much safer to test with water a pressure as there is much less stored energy. If we are testing with air on site we have to set up exclusion zone and all sorts of things. If we test with a fluid we don’t have to.
@undisutrisno2151
@undisutrisno2151 4 жыл бұрын
you should have a hoist mechanism in your workshop for your safety.. Good content video Sir.
@camarokurt
@camarokurt 3 жыл бұрын
I need to get a bore scope so can look inside mine. It's a 60 gallon Coleman I bought new in 2000 at CostCo. It only gets occasional use, but I live in a very wet and cold climate. It'll be interesting to see inside.
@JetSkiBuyFixPlaySellChannel
@JetSkiBuyFixPlaySellChannel 4 жыл бұрын
Interesting to see the condition of the inside of the tank. In the future you could remove the fixtures, hook up a pressure gauge, fill it with water then hook up a pressure washer to hydro test it yourself. Also you can get a boroscope camera that hooks up to your phone for less than $20.
@bvnseven
@bvnseven 2 жыл бұрын
Someone in another video mentioned that along with HD testing a tank. His EXPLODED..
@PMA85H
@PMA85H 5 жыл бұрын
Hydraulic testing, fill with water and pressurize and see if it holds for a specific period of time.
@andrewhigdon8346
@andrewhigdon8346 3 жыл бұрын
It might hold pressure but that’s the problem. You will never be able to predict when the walls of the tank have a thin spot from corrosion/rust. The more resistance to a burst, the more pressure it will take to burst, and thus the more explosive that burst will be. Take a bicycle inner tube and fill it till it pops. It’s a pretty strong pop. And that’s with thin rubber. Now do the same with an air compressor tank. What pressure will be too much? 80psi? 100? 120? 140? Care to try it out? Check out pics and videos of the results and you will not want to push your luck. One guy had massive damage to his garage from the air pressure. His garage door was even open, and it knocked it off the tracks, knocked the door rail anchors out of the concrete, broke every window, pushed out the window frame closest to the compressor, and basically knocked down or broke anything with any cross section in the garage. His wife was in the house and she said it shook the ground as much as any earthquake she had ever felt. If anyone had been adjacent to the compressor it would have surely killed them. The tank shot straight up to the ceiling/garage door tracks/door btw. Knowing that and seeing the damage was shocking.
@Ragnar8504
@Ragnar8504 3 жыл бұрын
@@andrewhigdon8346 That's why you test tanks with water rather than air. Water doesn't compress, so if the tank does pop, all you get is a bit of a splash rather than an explosion. And you test it to well above its rated pressure to make sure it won't fail under normal operating conditions. I'm not 100% confident I'd try this myself but I've seen it done and it seems reasonable.
@toastersock
@toastersock 5 жыл бұрын
I would have thought an explosion most unlikely, one of those pits would get so weak it would just give way and you'd hear a nice hissing. Also why would it crack, unless you'd damaged the outside severely somehow, since it has been clearly ok for 37 years? Elf and safety gone mad sir!
@whitacrebespoke
@whitacrebespoke 5 жыл бұрын
37 is nothing we have two 250 litre ones the youngest one is 55 years old. The other is much older. Both pass inspection every year. I was just thinking how sad it was to cut this up. What a waste. Out side in a shelter that would contain it if they popped it wouldn’t be a problem anyway.
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
Yeah I think most explosions would be due to the pressure regulator or pressure relief valve not working properly combined with a rusty old tank. Oh hold on... 😂👍
@timjohnson6864
@timjohnson6864 5 жыл бұрын
@@GosforthHandyman ive had tanks rist through they hissed i welded the hole shut to get the job done and didn't remember till the next year when another spot rusted through lol
@robertburgess9374
@robertburgess9374 4 жыл бұрын
@@timjohnson6864 Then watch this, and think again..... l.facebook.com/l.php?u=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3DKVP_A7eGYxw%26feature%3Demb_logo%26fbclid%3DIwAR08LhsBqi-LhRGkrIcYJCxBlpxMp9UNZ7JNoyTOGGeL7b06-R-P80GhC48&h=AT1-eecFdf5AqjejmEptqbJ_rCO_78f9XJXGmlphoi4TA_xm-7PqRsmYxuoq_C0SceRo8pN9ntij7LQKxZoqdiFpjIomxUrZ1tEDltvGNrxywXfTcnAkpGEIn0ldutSmKx41_QC0JVsgrn0Y
@rtj49
@rtj49 2 жыл бұрын
An explosion may be rare, but it does happen. Hydro-test results save you from injuries.
@Alex138bhp
@Alex138bhp 5 жыл бұрын
In a commercial setting, you should have an inspection done on a regular basis for your insurance where the tank is tested. Industrial machines should also have a autodrain on the tank (should be called a receiver) which limits water build up and increase the life expectancy
@woodshop7487
@woodshop7487 5 жыл бұрын
Fascinating Andy. Been around them for years often wondered what the inside was like. Had a good at the intro and the sombre music during the strip down. Bang on.
@lornejespersen4774
@lornejespersen4774 3 жыл бұрын
Hyd means that the tank was hydro pressure tested with water. This is the correct and only safe way to pressure test a tank.
@deadhead9296
@deadhead9296 2 жыл бұрын
Hydro testing is worthless on a rusted tank, they can easily hold the testing pressure but if there is rust inside and the compressor is back in use water will stay on that rust longer like a paper towel holds onto water and it will make it rust 10 times faster.
@rogerwilliams2902
@rogerwilliams2902 3 жыл бұрын
Excellent video, thanks.
@NomadMakes
@NomadMakes 5 жыл бұрын
That tank could be a great diy barbecue/grill :D
@nathanmiller9381
@nathanmiller9381 Жыл бұрын
was he cutting into that with a grinding disk?
@Rectitude4U
@Rectitude4U 9 ай бұрын
Great video. Pretty scary when you think about it. I’m not sure I even trust brand new tanks considering the quality of manufacture on everything nowadays. I’m going to make sure mine is far enough away from me in a worst case scenario.
@morganspencer-churchill2136
@morganspencer-churchill2136 Жыл бұрын
"The prime directive - we do not fuck with pressure vessels."
@johnthompson3462
@johnthompson3462 5 жыл бұрын
Wow, for 37 yrs that is fantastic.Doesn't owe anything
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
Yup - it's done well!! 👍👊
@embryonica
@embryonica 2 жыл бұрын
I did have a tank rust out on me and it didn't explode. It was the small 10/15L type and was about 15 years old. What actually happened was.. as you show.. a ribbon of rust pits or holes along the bottom inside of the cylinder and evenually one breaks through so you get a small whistle and obviously it doesn't hold the full pressure any more.. The first hole is probably only a pin hole but does make you aware... so you explore and quickly find the offending area.. You think about repairs.. bit of welding (can't do that..) an epoxy patch.. (nah..) screw a plate of metal over the area.. (probably the best option.. ) Have a cuppa tea.. think.. Snip off any extraneous useful looking bits and kick it to the curb.. Hello Machine mart.. whatchgotonoffer..?
@kris33451
@kris33451 Жыл бұрын
you got away lucky some of the units went off link a granade im a small closed garage blowing out all windows imagne you stand next to it
@ColinWatters
@ColinWatters Жыл бұрын
kzbin.info/www/bejne/jWOvk4d-m7ponLM
@mgomez5606
@mgomez5606 4 ай бұрын
I bought a Kobalt 26 gallon one. Its 15 years old but looks fine on the outside. Think in should look inside?
@mikefennema5561
@mikefennema5561 3 жыл бұрын
My Campbell Hausfield was purchased in 2000. It developed a pin hole leak in 2017 were the longitudinal weld meets the end bell weld. Tha autopsy revealed little rust were the pin hole developed but a heavy belt of rust along the bottom. The 13 gallon tank walls were only 3/32 inch metal.
@richardkenworthy9312
@richardkenworthy9312 Жыл бұрын
That was interesting, I own a stand up compressor, I keep the drain valve open at all times. I was wondering if the stand up type would be better because the condensation would drain out better.
@MrKentaroMotoPI
@MrKentaroMotoPI 11 ай бұрын
These are better for several reasons. Water collects mostly in the lower dome. The domes are stronger than the cylinder section. The dome weld is far away from the water. Any failures should occur at the bottom, and resulting thrust should be vertical (like a rocket taking off). The compressor weight, plus the anchor bolt strength will likely resist that thrust (I've done the calculations). Also, with a vertical tank, the air discharge port is further from the water on the bottom, so you get much less water in the air. I run spray guns, and water is a huge issue. Not great for your aluminum turbine tools, either.
@MrKentaroMotoPI
@MrKentaroMotoPI 11 ай бұрын
If you depressurize the tank when not in use, you'll never have an issue. Significant rust only occurs at high pressures.
@richardkenworthy9312
@richardkenworthy9312 11 ай бұрын
Thanks for all the information, good to know
@cosmicallyderived
@cosmicallyderived 5 ай бұрын
Why would rust be pressure dependent?
@richardkenworthy9312
@richardkenworthy9312 5 ай бұрын
@@MrKentaroMotoPI yes condensation forms from change in temperature
@colinweir5807
@colinweir5807 2 жыл бұрын
Hyd. test is probably hydrostatic test pressure. Filled with water and pressurised. I did this sort of testing as part of my fitter / machinist apprenticeship. Company manufactured flow control and safety release valves.
@Bill.L.Carroll
@Bill.L.Carroll 5 жыл бұрын
Workshop wood heater would be the way to go, mate👍 Seen a video where an oldie let go with a hell of a bang, caught on CCTV, Grandson, luckily was home at the time, severely sliced through both granddad's legs...😨
@TalRohan
@TalRohan Жыл бұрын
Just before you start cutting is where you hope it was actually dead... extremely interesting to see just what happens in there and how well the airmaster compressors were made. But I am now thinking about the old one I just replaced and thinking I should recycle it.
@andrewreid4337
@andrewreid4337 5 жыл бұрын
Very interesting Andy, that’s what put me off buying a 2nd hand one. I’m sure most would be fine but the peace of mind from a new one is almost priceless. Could that be a video or podcast idea for you. To buy new or used?
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
I think we covered it a little bit on one of the past episodes... I think. Or perhaps we meant to and went off on a tangent. 😂👍
@andrewreid4337
@andrewreid4337 5 жыл бұрын
Gosforth Handyman sorry you are totally right! That’s maybe why I thought it was a good idea, I’ve already heard you do it! 🤣
@birddavid3881
@birddavid3881 4 жыл бұрын
The HD stamp is hydro test , in order for any tank to be allowed as a compressor it has to be tested using water or glycol . that was my job when I worked on oil seperators, we would have to fill the tank from the bottom (if done from the top you will have air and will not be able to test) we had to test 1 1/2 times the working pressure which is where the 225 stamp comes in. It's a max psi of 150 so 150 +75 =225 . it has to hold that pressure for 15 min. And all welds are checked for any leak. By law anything over 110 psi has to be filled with liquid so that if there is a stress crack , or a faulty weld you take a quick shower otherwise goid chance your not going to be around for any other test as it will explode like a grenade shooting metal into whoever is near the tank. If a tank gets to thin from water, rust you can cut a section out and basically put a new piece in a band aid . the second serial no. Is logged into a federal data base which is a paper trailall the numbers on that tag will tell you where that steel waa milled and when , who welded on that tank , who pressure tested that tank and who did the final inspection giving that tank a pass to become a compressor. So all them tags and numbers are it's birth certificate if you will.
@TheKernelCollective
@TheKernelCollective 5 жыл бұрын
The hyd test is hydrostatic test. You fill it with water and test to usually 1.5x mwp.
@grahambambrook313
@grahambambrook313 10 ай бұрын
For anybody interested, the formula used to calculate the hoop stress in a cylinder, (the most heavily stressed part being the parallel sided portion) is PD/2T, i.e. internal pressure x diameter divided by twice the wall thickness. With deep drawn cylinders the burst failure is normally a straight line down the longitudinal axis; with welded (rusty) tanks it can be more chaotic but it is surprising what decent steel can withstand. Even the humble 15mm copper pipe can theoretically withstand more than 20 bar of internal pressure, though I don't think I'd like to cycle it too often!!
@cookinitmax
@cookinitmax Жыл бұрын
Can you treat the in side with an rust prohibitor ? I bought a new Makita air compressor I see rusty water come out when I drain it .
@MrKentaroMotoPI
@MrKentaroMotoPI 11 ай бұрын
I've seen comments from people who did that and it was ineffective. High end brands, like Schulz, powder coat the tank inner walls at the factory. Don't worry about your Makita. The drain water will be rusty from day one. I have a 30 year old Ingersoll Rand (U.S. made back then). It's drain water appearance has been consistent over the decades.
@ifixeditmyself1926
@ifixeditmyself1926 7 ай бұрын
Thanks for this video! 👌🏽
@Equiluxe1
@Equiluxe1 3 жыл бұрын
I think that small pressure tanks are supposed to be replaced after ten years from test date,in industrial and commercial use they have to inspected on a regular basis by a competent person like once a year, insurance companies will usually arrange this.
@mihamaker
@mihamaker 5 жыл бұрын
I tought that you used thick grinding wheel on purpose instead 1mm cuting one :-)
@chrisbraid2907
@chrisbraid2907 Жыл бұрын
The recommended lifespan varies with the respect it has received and the regularity of the emptying of water from the tank. Oil level is important too …
@panchomcsporran2083
@panchomcsporran2083 Жыл бұрын
I used to sell these (at Machine Mart) if you have a compressor ten years past the test date stamped on the tank, be careful, they should be tested. Or you can buy new tanks separately, these old pumps and motors are far more reliable than the new ones. We would scrap loads of compressors with burnt out motors or seized pumps (most only 2,3 years old) so speak nicely to the staff.
@luigifabio77
@luigifabio77 3 жыл бұрын
The correct way to do this would have been to perform a 'house' hydraulic test first, then open it up and see how the steel was, thus establishing at least some correlation. As it is we have no actual information, though given the 2.4mm residual thickness I agree with a prior commenter, it would probably last about as much at is already has at least.
@ldnwholesale8552
@ldnwholesale8552 8 ай бұрын
A cut off wheel instead of a grinding disc cuts a LOT more efficiently
@ThePlayerToBeNamedLater
@ThePlayerToBeNamedLater 2 жыл бұрын
My POS porter cable pancake actually has a 'don't use tanker after' date stamped on the bottom. That date is 2022 so I'm shopping for a new one.
@robthewaywardwoodworker9956
@robthewaywardwoodworker9956 5 жыл бұрын
I have a shop compressor (80 gallon) that I installed in my shop when I was a teenager! So it's like 39 years old if my math is correct. An old DeVilbiss horizontal unit That I used to work on cars (instead of getting into trouble!). I replaced the bypass about a year ago and it was so badly corroded! It was leaking air and I hadn't used it in some 5 years or so. But an old change (first ever) and she runs like a champ. No idea what the inside looks like, and I'm not sure I want to know. It was always drained after use and I do live in a pretty dry climate so I have never even had anything showing in the line dryer. It keeps me going, but it sure does take up a lot of room and it's hella noisy!
@davorinrusevljan6440
@davorinrusevljan6440 5 жыл бұрын
hyd probably stands for hydro, usual way of testing pressure vesels - it gets filled with water not air, that way if vesel fails it is much less dangerous
@olly5455
@olly5455 5 жыл бұрын
Davorin Ruševljan Hyd stands for hydraulic as in hydraulic test pressure
@davorinrusevljan6440
@davorinrusevljan6440 5 жыл бұрын
Thanks!
@h8GW
@h8GW 6 ай бұрын
Geez, I can't wait until technology advances to when we can shape titanium cheaply enough that we won't have to worry about air tanks corroding and exploding. ...then again, by that time, air tools would've been completely replaced by battery tools.
@jimrojas62
@jimrojas62 4 жыл бұрын
About 24 years ago, we replaced the 100 gallon tank in our 30 year old shop compressor with a 125 gallon stainless steel tank. We bought the tank from a scrap yard for $50. Now we don't have to worry about it exploding anymore. It is still in use today.
@Agnemons
@Agnemons Жыл бұрын
Stainless steel has completely different characteristics to "plain" steel (there are so many variants, not sure what is used in pressure tanks. I would assume it is a high tensile steel) Particularly with regard to stress cycles.
@jimrojas62
@jimrojas62 Жыл бұрын
@@Agnemons The new tank is 1/4 in thick 304L SS. I believe it was removed from a brewery. It is heavy. It still has the same compressor after all these years. When the compressor finally dies, I would like to replace it with the newer silent compressor.
@cmdrdarwin3682
@cmdrdarwin3682 2 жыл бұрын
I recently heard about a guy’s compressor exploding & nearly destroying everything within 6 ft of it. I was not aware this was even a problem, but clearly, it is. This begs the question as to why compressor manufacturers don’t heavily treat the inside of these tanks or use a liner of some sort? Have there not been any liability lawsuits from people injured or damage to property? One would think there would be a standard of time or use to go by…
@nukeyly4901
@nukeyly4901 Жыл бұрын
This old one it was fine in your shop 5 yrs ? 15 yrs ?
@tejasvisam9054
@tejasvisam9054 2 жыл бұрын
Stainless Steel tanks can be used right to avoid corrosion?
@rgriffith6476
@rgriffith6476 Ай бұрын
Its old machinery, of course it still works. No PCB board, no pre-installed failures... Solid item. Personally, I have always been terrified of air compressors, as well as flammable gases . Worst of all, flammable compressed gases (propane tanks, butane cans) and I have always wondered why these aren't made of stainless steel, or at least coated internally with a paint or protectant to prevent rust... I mean, the inside is never touched by solids, it wouldnt degrade at all presumably...
@36736fps
@36736fps 5 жыл бұрын
I have always been curious about what the interior looks like after a few years. Now I know and I am not happy.
@hansdegroot8549
@hansdegroot8549 5 жыл бұрын
37 is a little bit more than " a few years".
@simonm1447
@simonm1447 3 жыл бұрын
Uncoated tanks have reserves, so they are stilll stable enough if they are weakened by rust, at least for some time. You can hydro test such tanks, you fill them completely with water (which is not compressible), remove the pressure relief valve, and pump it by a external pump (pressure washers also work) to 1.3 to 1.5 times the maximum working pressure of the tank. If the tank is ok it's fine and nothing happens, if it was faulty it will only rupture with a small plop (because you can't compress the water, so it can't explode). However you can be sure after this test if your tank is ok, or not.
@caskwith
@caskwith 5 жыл бұрын
I don't know why more compressors don't come with a 1/4 turn valve for draining. I have a 1/4turn on my big compressor and a screw type on my small compressor. The big one gets drained everytime I use it, the small one gets drained about once a year.
@jimzivko9742
@jimzivko9742 3 жыл бұрын
I would have removed the end plug and used a lighted scope to check the interior .
@TriodesPs111
@TriodesPs111 2 жыл бұрын
hey whats the song at the beginning?
@TheStrongwomans
@TheStrongwomans 5 жыл бұрын
Interesting video compressor is nearly as old me You could make cool light out some of the parts
@tribulationprepper787
@tribulationprepper787 3 жыл бұрын
Yeah, Just don't use it as a ceiling fixture!
@glasslinger
@glasslinger 3 жыл бұрын
That guy is clueless on how to lift a heavy object to the bench. I was waiting for the OWWWWWW as his back threw a disk!
@stevenholden9520
@stevenholden9520 5 жыл бұрын
At work I took over responsibility for an at least ten year old clark whisssper all in one compressor. I could hear water sloshing about inside the tank. I removed the drain tap and strangely no air or water came out. on further investigation I found that although the drain threaded boss had been welded to the tank the tank had not been drilled by the manufacturer. I returned the unit to Clarks R & D dept. it came back a few weeks later with a hole drilled through the drain boss so the drain tap worked. strangely enough it failed completely a few weeks later. I wondered how many of that batch hadn't had the drain hole drilled through at manufacture.
@MrDoboz
@MrDoboz 5 жыл бұрын
wow... good to know which brand I'm NOT goung to buy from. thanks
@OprichnikStyle
@OprichnikStyle 3 жыл бұрын
3:14 Hydraulic test. it's a test where you add water under pressure and see until where it can hold that pressure. I've done it in a boiler with a manual pump and let me tell you it's not a small feat. Generally the hydraulic test is done @ 200%- 250% the real working pressure
@markrainford1219
@markrainford1219 3 жыл бұрын
That reminds me. I've not drained mine for a couple of years. Maybe that's why it acts more like a pressure washer than a compressor :)
@samuelguest5536
@samuelguest5536 3 жыл бұрын
Funny that, mine gets drained fairly often and it's more of a pressure washer too
@randywl8925
@randywl8925 Жыл бұрын
@@coldblu357 I've always wondered how moisture gets out of a compressor. You drain all the water out but the humidity stays in there unless it somehow evaporates out of that tiny valve hole. You may not have standing water but you'd have to leave the tank out in the sun for quite a long time for it to actually dry out inside.
@mrnice88x
@mrnice88x Жыл бұрын
@@randywl8925 When the air gets pumped in hot it creates moisture. Some people coil the feed line from the pump to the tank or add an air cooler in line to help with moisture. I learned it from the guys that paint, they know all the cool tricks.
@markrowland5393
@markrowland5393 5 жыл бұрын
Hyd. stands for hydraulic. As other comments have said, liquid (hydraulic) testing is much safer than gas (air) testing 'cos if it fails it won't explode - but you might get wet!
@carba8606
@carba8606 3 жыл бұрын
Well done....very good video
@simonpfotenhauercapetown7055
@simonpfotenhauercapetown7055 5 жыл бұрын
In your opinion, what or how much is the danger if a pit is extremely deep and the tank 'bursts'? It'd be most likely on the bottom? Would one not merely hear a slight hiss like a tyre leaking?
@DocScience2
@DocScience2 Жыл бұрын
There are videos describing a tank failing (pictures of tank included) when the person was in the garage, and had he been in the wrong spot, would have killed him. . Blew the garage windows out,
@Mole-Skin
@Mole-Skin Жыл бұрын
All Compressors have a Safety Valve. The tanks are designed to take at least 600psi which is probably 3 x the pressure your engine/pump could deliver.
@neilgillies6943
@neilgillies6943 5 жыл бұрын
Not sure where the 'limescale' on the drain valve would come from, the water gets condensed from the air :-) I got a wee Stanley air nailer compressor, can lift it with one hand - scares the $hit out me when it fires up unannounced :-))
@GosforthHandyman
@GosforthHandyman 5 жыл бұрын
Ha - very good point! I'm sure I've seen stuff that looks like limescale on there? Probably just rust. 😂👍
@notbuyingit8047
@notbuyingit8047 2 жыл бұрын
I doubt they make them anywhere near that wall thickness anymore.
@cjhification
@cjhification 5 жыл бұрын
Hydraulic test for HYD. Test I would think as I have to get my scuba air tanks hydraulicly tested every 5 years with a visual inspection in between at 2.5 years
@peacockealot
@peacockealot 5 жыл бұрын
One of the guys I dive with hasn’t had his cylinder tested in 15 years. I don’t know where he gets it filled because he’s not allowed to fill it with the club compressor and I refuse to fill it for him with my compressor either.
@cjhification
@cjhification 5 жыл бұрын
@@peacockealot was just about to ask does he have his own compressor then as no one else is likely to want to fill it up.
@tanello2
@tanello2 4 жыл бұрын
I have a soviet compressor, an old man used it für 40 yrs and i borrowed it für one day and end of the day the tank started to leake air at the welds, turned out its lifespan was exacly 40 yrs.
Don't make this mistake with your home shop air compressor | Auto Expert John Cadogan
24:25
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 58 МЛН
Air Compressor Explosion Prevention. Hydro Test.
10:10
Robert Deptula
Рет қаралды 53 М.
tubalcain performs an AUTOPSY ON A COMPRESSOR AIR TANK
11:35
mrpete222
Рет қаралды 107 М.
Air Compressor Simple Upgrade - CHEAP & EASY - Increase Tank Capacity!
10:26
Timelapse of our entire 1920’s house renovation
28:34
Gosforth Handyman
Рет қаралды 2,5 МЛН
Whip Check Failure
4:25
Steve Beeson
Рет қаралды 25 М.
Junk Air Compressor, can we fix it?
47:48
Mustie1
Рет қаралды 839 М.
Q/A and conclusion on blown up air compressor
7:32
3Generation Racing
Рет қаралды 79 М.
Hydro Pressure Testing a Air Compressor Tank
8:36
Keith Rucker - VintageMachinery.org
Рет қаралды 173 М.
What are house walls actually made of?
27:31
Gosforth Handyman
Рет қаралды 45 М.
Making an auxiliary air tank from an old LPG gas bottle.
12:05
Handmade Extreme
Рет қаралды 929 М.
I lost my kitten on the street😭 #cat #cats
0:32
Prince Tom
Рет қаралды 152 МЛН
他们在说什么,不能当面说。#海贼王#路飞
0:15
路飞与唐舞桐
Рет қаралды 9 МЛН
Amazing 3 iPhone Trick Shot
0:32
That's Amazing Shorts
Рет қаралды 68 МЛН
Waka waka #2 🤣 #shorts
0:15
Adani Family
Рет қаралды 29 МЛН