I can't imagine such good equipment as we are too corrupted. Thanks from Bangladesh.
@goru426 Жыл бұрын
I love these rubber O-ring connection... there will be so many ACs to fix in the future. Easy money for the AC guys.
@Cody-ye3ye Жыл бұрын
We had 100% failure rate on these 3/4 size and used outdoors only
@RingZero3 жыл бұрын
SharkBite technology has touched the HVAC market as well :-) One thing I have yet to see in a home is the homeowner being notified or alerted by the system if the refrigerant is low. This way, the HVAC service could be reached out to appropriately... Nowadays the HVAC service scheduling drama on the front desk is out of control and all home owners who have had HVAC issues could attest to it. The positive side of all this is, it is making a homeowner with minimum DIY tech how-to knowledge to become an HVAC tech, similarly how some of the homeowners are already great auto techs, electricians and plumbers. Not bashing anyone here, just exposing the reality. I truly appreciate all the hard work you do and also the new techs that study hard to get certified in trade schools.
@MrDavewane2 жыл бұрын
Did my first mini-split installation using these fittings yesterday. All good so far. I like them, although they are quite expensive in Australia.
@RectorSealCorp2 жыл бұрын
Happy to hear, Dave! Thanks for being a RectorSeal fan.
@dporrasxtremeLS39 ай бұрын
Outstanding Fittings! A Must Have According to Leading Installers. @@RectorSealCorp
@kyleb3293 Жыл бұрын
Think I'll try these on my next install! I for one am not bothered by PTC and/or o-ring'd joints. Heck they're all over your vehicles/hydraulic equipment. So much mission-critical infrastructure is using PTC/o-ring joints and you have no idea! 5 year warranty on the o-rings doesn't inspire confidence though. Wouldn't HNBR have performed a bit better than CR o-rings?
@chamflas Жыл бұрын
What if it fails, do i get a replacement of the fitting or $$$ back
@jeffmohler71273 жыл бұрын
The vibration test past at 50 psi. I guess I'm impressed. HVAC system pressure is only 6 or more times that!
@dporrasxtremeLS39 ай бұрын
Your an Empty glass...Mr. Complainer/ Whinner!
@genepierson17282 жыл бұрын
Thanks for the video. What's the life expectancy of the fitting? Before the o-rings fail I mean.
@RectorSealCorp2 жыл бұрын
Great question, Gene! Our O-rings are covered with a 5 yr warranty. They should not deteriorate especially with the dual o-ring design.
@genepierson17282 жыл бұрын
Thanks for the reply. I'll go with the Zoom Lock 410a optimized which have a 10 year warranty. Do you have any that are 410a optimized, warrantied for 10 years?
@daveyt4802 Жыл бұрын
These work just as well under high vacuum levels?
@johnbigwood-w7b4 ай бұрын
can these be used for water
@shaystar93472 жыл бұрын
good video
@carllungwitz5171 Жыл бұрын
What is the pressure drop across the 90s? Especially on a vapor line, they look like the don't have any sweep to them.
@wesmoore66313 жыл бұрын
did I miss the vacuum test? My question how reliable is this system when evacuating air from refrigerant lines?
@MrDavewane2 жыл бұрын
I used these fittings for the first time yesterday on a new installation of a mini-split. Obviously I vacuumed the lines, and in fact left them under vacuum ovenight. No change. I then commissioned the system and all looks good. These fittings are ideal for hard to get to places or where brazing may be a hazard. Or where a press tool may not be able to be used due to lack of space. So far so good. They are expensive (in Australia) but they sure have a role in many situations.
@JeroenSmulders-xm6iv Жыл бұрын
is there any way to buy them in The Netherlands?
@RectorSealCorp Жыл бұрын
Jeroen please contact our customer service team to assit you. rectorseal.com/customer-support
@michaelwalker5880 Жыл бұрын
can the be used to connect copper propane lines?
@williamsantana7443 Жыл бұрын
For hospital units
@williamsantana7443 Жыл бұрын
Who does it work on industrial units
@doriascomfortsolutions77402 жыл бұрын
On the socket type fitting. When torquing them to mini splits. Do we go by the torque from the manufacture ? Or is there set torque for the fittings ?
@RectorSealCorp2 жыл бұрын
Doria here are the Torque settings. • 1/4": 426.7 to 568.9psi • 3/8": 426.7 to 568.9psi • 1/2": 568.9 to 711.2psi • 5/8": 711.2 to 853.4psi • Service valve stem release torque: The pipe should not fall out below 2,275. 7psi
@johnnyledfut26253 жыл бұрын
Be nice if they made some of these fittings with a check valve
@RectorSealCorp3 жыл бұрын
humm good idea. We will pass it on to our team.
@UltraHydrophobiccoat Жыл бұрын
Does it work in freezers? And iron tubes?
@RectorSealCorp Жыл бұрын
Unfortunately no, copper and coated aluminum linesets only.
@DWAYNE2ism4 жыл бұрын
Can the service valve use to change a leaking service valve like on a mini split
@joecox99583 жыл бұрын
how you connect to condenser and evaporator? or else you are mid way
@wd85573 жыл бұрын
40 bucks for one 7/8 fitting. I'll stick to Stay Brite 8 on new installs.
@picklerix61623 жыл бұрын
Me too. Nothing cuts into your profit margins faster than overpriced hardware.
@nukestrom57193 жыл бұрын
Stay Brite 8 for refrigerant lines?
@wd85573 жыл бұрын
@@nukestrom5719 obviously you haven't what I said. It's stronger then 15% brazing rods. When I use that on a chiller holding 800 pounds of refrigerant and never had any leaks.
@Reloadeez3 жыл бұрын
@@wd8557 I'm a braze guy but use SB 8 for some things, It's fine. Gets bad rap from hacks not prepping and fitting up right.
@sprockkets3 жыл бұрын
People have used this to solve leaks with mini splits on the gas side thanks to heat mode. I would use it for that.
@familywest16973 жыл бұрын
Quick question........Why did you sweat the service port into the test rig?......lol
@SirHumano973 жыл бұрын
2 different size copper tubes. I guess they dont make reducers.
@darrenbond84852 жыл бұрын
Good point, they do make reducing 90's and couplings.
@nickbengel60042 жыл бұрын
What is the brand and model of the rounding tool at 9:38?
@TomwithBirdsallАй бұрын
That appears to be the Yellow Jacket 60407 expander tool
@zachosborne6577 Жыл бұрын
These wouldn’t be helpful on new installs unless you change out every service valve with one of the quick fits. Maybe to pull and clean an evaporator, you wouldn’t have to braze if you use the union quick fitting. Possibly to relocate a condenser.
@fanzfanzilla11 ай бұрын
Will this work for regular full size residential HVAC systems?
@RectorSealCorp11 ай бұрын
It works for systems with refrigerant lines up to 7/8"!
@fanzfanzilla6 ай бұрын
@@RectorSealCorp Do you have 3/4 to 7/8 reducer fitting? My port is 3/4 and line is 7/8.
@familywest16973 жыл бұрын
You guys are cheaping out on your warranty. You want me to buy and install these over priced fittings? Then the warranty MUST be at least 10 years, same as an equipment manufacturer.
@genepierson17282 жыл бұрын
How the long is the warranty? I can't find it
@scottstradtner Жыл бұрын
@@genepierson1728 same as solder.
@scottstradtner Жыл бұрын
Fire will not be more popular in the future than it is today.
@brunoburga3156 Жыл бұрын
These are nothing but trash. I manage a large apartment building with 300 units, where these fittings were used, we had hundreds of service calls due to these fittings leaking, since day one when we open the building, we only been open for 8 months. Our hvac sub will not use them at any other projects in the future.
@gregs95554 ай бұрын
Just had to remove 3 of these leaking pos fittings today, absolute garbage.
@ragenhamilton46793 жыл бұрын
These are Perfect! The new refrigerats all have Isobutane in them...So, we are all going to this anyway. and anybody using Sta-Brite #8 with R-410a, souldn't ne doing HVAC ANYWAY...
@wd85573 жыл бұрын
I suggest you call the manufacture before you make a stupid comment like that, because you have no idea what you are talking about. It has a stronger PSI rating then 15% brazing rod. However you would not know that would you?
@garyomglol3 жыл бұрын
He haven't got the slightest idea, thinking its plumbing solder LOL!
@johnlott72403 жыл бұрын
@@wd8557 Passed with my manufacturer's warranty. It's great stuff. Only issue I've had is one installer used to much on the liquid line and caused a restriction, but that's not the products fault. Don't even have to N2 purge. Clean Clean Clean
@wd85573 жыл бұрын
@@johnlott7240 liquid line should be done in 5 seconds lol. He will get it down.
@jonnymac314 жыл бұрын
Sad to see this.
@nestes863 жыл бұрын
Well, I'd say these are good for mini splits in certain situations since you are not supposed to braze on mini split linesets.
@jonnymac313 жыл бұрын
@@nestes86 sweep nitrogen and it'll stay as clean as the moment it came off your truck. And a bonus it won't leak in the years to come.
@nukestrom57193 жыл бұрын
lol
@sprockkets3 жыл бұрын
@@jonnymac31 and for the outdoor unit end? Lol.
@scottstradtner Жыл бұрын
No Flame applications will only be more common in the future. The only thing constant is change my friend.
@highdegree5440 Жыл бұрын
😂🤣
@truthseekerKJV Жыл бұрын
This method is a terrible choice that will result in numerous call backs, increased overhead costs, negative ratings from unhappy customers, and a loss in profit due to leaking. The high pressure and temperature changes on the fittings will always require brazing. I'm surprised the EPA, with their complaining about the ozone being damaged by refrigerants, haven't outlawed this seriously flawed method.
@jcook69camaro Жыл бұрын
so they come to the rescue for the techs out there that don't know how to do their job correctly. I have been in the HVAC industry for 40+ years and never had a brazed joint leak in my life. What happens when a system running on 410 has a fan motor go out and head pressure goes to 600+ pounds? run your test with high temperature and high pressure as in a discharge line.
@soundslikebstome3 жыл бұрын
Anything that has an O-ring is destined for failure. The copper has to be perfectly round. Copper can be smashed flat and opened back up with a screwdriver and beat back semi round with a rock, then be brazed leak free for eternity. Who in the hell is gonna spend crazy $ for one joint when you can braze a lifetime joint for pennies. Making a simple process into brain surgery.
@Reloadeez3 жыл бұрын
Hacks
@sprockkets3 жыл бұрын
Mini splits
@darrenbond84852 жыл бұрын
You're mostly on the money here up until the price point. I'm not sure if you've looked at your invoices when you've bought fittings, 15% brazing rods or acetylene in the past few years but the accumulation of these three is getting up there.