Zoom Lock Push Fittings R410A Optimized - A Brazing Alternative

  Рет қаралды 49,331

HVAC Know It All

HVAC Know It All

Күн бұрын

Пікірлер: 137
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I enjoyed the experience
@omarijohnathan3777
@omarijohnathan3777 3 жыл бұрын
I dont mean to be offtopic but does anybody know of a trick to log back into an Instagram account? I was dumb lost my account password. I would appreciate any help you can give me.
@daltonkyrie6975
@daltonkyrie6975 3 жыл бұрын
@Omari Johnathan instablaster ;)
@omarijohnathan3777
@omarijohnathan3777 3 жыл бұрын
@Dalton Kyrie I really appreciate your reply. I got to the site on google and im waiting for the hacking stuff now. Seems to take a while so I will reply here later with my results.
@omarijohnathan3777
@omarijohnathan3777 3 жыл бұрын
@Dalton Kyrie It did the trick and I now got access to my account again. I am so happy! Thanks so much you really help me out !
@daltonkyrie6975
@daltonkyrie6975 3 жыл бұрын
@Omari Johnathan Happy to help :)
@sharky5570
@sharky5570 4 жыл бұрын
These will become very popular, some companies won’t let you take torches up on a roof to do repairs. I know it sound stupid but it is a fire risk that companies won’t let you take the risk. Great video
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Woth some time yes they will
@hkhsm359
@hkhsm359 4 жыл бұрын
nice tool that can be use hard place to braze and many place& regulation about fire etc and other requirements. thanks for sharing. and it will be nice to make vacuum test also.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I will try to get that done as well.
@nsudatta-roy8154
@nsudatta-roy8154 3 жыл бұрын
I have been relying on propress. Luckily, most modern systems don't last much longer than 10yrs. I believe the O-ring in propress is rated for 10yrs.
@karlschoen7297
@karlschoen7297 4 жыл бұрын
Seen them@ the supply house would be interested in the longevity of the fitting due to the expansion and contraction of the pipe
@tuvoca825
@tuvoca825 10 ай бұрын
Yes. Freezing and thawing cycles, with external moisture.... Show us how that goes. Too many products are not tested in "all" conditions.
@CMN843HVAC
@CMN843HVAC 2 жыл бұрын
I have been at a house all day today fixing a Trane tam9 multi stage system tube kit had everything brazed and bi filter in tried pulling a vacuum thought my hoses were bad turns out the system has the non 410a fittings under the house and the house has 2 systems and the other line set has them too thanks for this vid because I didn’t know there are different fittings for 410a until today I’m just a (braze it ,sewage it )kind of guy . Keep up the great vids 👏👏👏👏
@Froggin87
@Froggin87 4 жыл бұрын
A cool test I'd like to see is you using them hooked up to a system outside (like your own house to be easy) where the weather, temperature, season changes, and moisture are all affecting it and soap bubble testing it after a year and then 2 years and such to have update videos showing the progress of the fittings.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Now that's commitment lol
@tuvoca825
@tuvoca825 10 ай бұрын
Yes. External water freezing against that seal... would be a concern outside for me. Testing in the real world... a good idea!
@DanO181919
@DanO181919 4 жыл бұрын
Interesting, definitely very well made. People talk about Shark bites for plumbing but Ive never seen one fail.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I've never used a Shark Bite, time will tell
@PaulHVAC1
@PaulHVAC1 4 жыл бұрын
I have seen them fail. Share bite does not like extreme cold. Had a customer who furnace failed in -25C temperature for about a weak. The house froze up. The hot water tank, someone installed it with Shark bite connector. The shark bite fitting blew right off the pipe , so there was full water blowing out the pipe in the basement for days. What a mess! Also I have been getting a lot of calls for those Shark Bit hot water tank hose connectors , a lot of "Plumbers" are using these days to reduce install time on tanks installation. What we are seeing is the rubber inside them is deterioration over time and customers are seeing black slime in their tubs when they fill up the tub. Everything has there place but if you can avoid them I would.
@DanO181919
@DanO181919 4 жыл бұрын
@@PaulHVAC1 Pro press fittings have the rubber o-rings too. Just built a 100O room hotel in my area, nothing but pro-press. I’m thinking they will fail too.
@PaulHVAC1
@PaulHVAC1 4 жыл бұрын
@@DanO181919 Seems its all about saving money by reducing labor. If they can hire a apprentice to send out with the press tool, they can make more money by the savings on not having as many journeyman doing the work. Basically you can train a monkey to install this quickly. Like I say there is a place for everything. Maybe use it in a area were using a torch is hazardous....but we all know companies will use this for making more profit on cheap labour.
@tuvoca825
@tuvoca825 10 ай бұрын
I saw someone use one on galvi after pulling out the collar. You aren't supposed to do that but it was a DIY guy who did it on a weekend emergency because he had no shut-off and just needed something to stop a flood while they waited for the plumber. They 'should' thread the pipe and and put a valve on it but he was in a hurry and wanted something quick and temporary and didn't care as much about reliability.
@tripplewhipper
@tripplewhipper 4 жыл бұрын
I had a ball valve on a yellow jacket hose leak after no more than a year and it was a real headache when trying to find out why I had shitty decay on a vacuum. Definitely switching to a legit kit like you've demonstrated in other videos
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
This why we shouldn't use charging hoses for evac 😉. You'll enjoy your new rig
@tripplewhipper
@tripplewhipper 3 жыл бұрын
@@HVACKnowItAll was early on in the trade, live and learn.
@misterdude206
@misterdude206 4 жыл бұрын
Good idea, saves time and situations where you might need to acquire a hot permit. Although I dont like the size of them. For residential or small scale jobs, putting those stacked in line hide may be a pain.
@AK-oz4ew
@AK-oz4ew Жыл бұрын
I believe it is a minimum 24" distance for brazing of 7/8 with wet rag, 20" with 3/4 and so on - same as for zoomlock max. Good that it worked. An easy option for DIY. They have leak rate however, .1 oz per year per joint.
@tuvoca825
@tuvoca825 10 ай бұрын
Not many DIY guys with an EPA lisc....
@proanswers
@proanswers 4 жыл бұрын
On your removal test of the zoom lock fittings, would be interested in seeing if a box end wrench would remove the fitting. We say this because in the plumbing industry a push to connect fitting works as a removal tool i.e. sharkbite brand, gator brand, parker brand we DO NOT utilize the plastic REMOVAL tool a 5/8 in to 7/16 in open box end wrench depending on dia of push to connect fitting. Works with better leverage then the plastic disconnect the manufacture tries to sell i.e some water supply SharkBite valves come with a built in disconnect but again different industry. "The wire" portion must play into the locking and unlocking safety factor Our best practice on push to connect fittings if we cant see the fitting in the final install we dont utilize a push to connect - meaning no hiding behind walls or poor access areas.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Some more to think about and test then haha
@proanswers
@proanswers 4 жыл бұрын
@@HVACKnowItAll dont understand your comment
@abazism
@abazism 3 жыл бұрын
Thank you for your demonstration
@kswel10
@kswel10 3 жыл бұрын
The fact that it’s only rated to 500 microns worries me. New installs I like to pull to 200 microns and rise below 500 microns. Would this pass a decay test if it’s only rated to 500 microns
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
According to specs they are rated for 200 microns, where did you read 500?
@kjfacilities-maint
@kjfacilities-maint 2 жыл бұрын
Great demonstration!
@joemccormick4484
@joemccormick4484 4 жыл бұрын
Will be a while before we see these in Canada. I would have liked to see you pull a vacuum on these fittings.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
I will on the next one
@backwoods_legit7066
@backwoods_legit7066 4 жыл бұрын
They are rated down to 30 microns
@Tthel90
@Tthel90 4 жыл бұрын
Very cool! Wonder if these will be worth using given the price
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Can see applications where they'd be handy
@timsky99
@timsky99 3 жыл бұрын
A bit late to the party, but in the field the pipe's gonna need lagging. So are you meant to buy special sections that fit over the elbows then glue and tape them to the insulation that butts up to it? At the risk of sounding like a ludditte, I'm sticking to pipe benders and brazing thanks - this looks like a lot of pissing about.
@unclebudsfarm1169
@unclebudsfarm1169 3 жыл бұрын
Please explain "410-A optimized" fitting vs non optimized??? Differences? Application?
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
410a is for higher pressure refrigerant, use them on 410a systems
@williamturner573
@williamturner573 4 жыл бұрын
Can you do a vacuum test?
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
At some point yes
@mexicant777
@mexicant777 Жыл бұрын
This is revolutionary
@pubchat2913
@pubchat2913 3 жыл бұрын
This is cool, from the same guys that own RLS? I think RLS fittings can hold more pressure thigh and are a little more forgiving with the prep. P.s being able to still swing the pipe while attached is both awesome and kinda nerve racking haha if you know what I mean
@MrDjmurdock
@MrDjmurdock 3 жыл бұрын
Only time will tell how they stand up. The more we take torches out of techs hands the better.
@petergregoretti4226
@petergregoretti4226 2 жыл бұрын
Can u use these on copper to aluminum??
@HVACKnowItAll
@HVACKnowItAll 2 жыл бұрын
I think only copper but not 100%
@jyphc1679
@jyphc1679 4 жыл бұрын
These are quick connect similar to shark bite connect I wonder if the same company make the shark bite made them to !!🤔👍👍👍
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Not sure about that one!
@sungbumkim1703
@sungbumkim1703 4 жыл бұрын
Shark bites are for water line, means working pressure is under 280psi max. This ZL push fittings are working at Max 870psi even high. Big differant.
@enejihillary4007
@enejihillary4007 2 жыл бұрын
Can we use this coupling on a hard pipe and pressure up to
@rivergate950
@rivergate950 2 жыл бұрын
yes and about 800psi
@matthewlitvak2695
@matthewlitvak2695 3 жыл бұрын
Thank you, excellent video and explanation.
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
My pleasure
@craigmarshall40
@craigmarshall40 Жыл бұрын
I was out on a call for a mini split and it had those fittings and it was a few years old and fitting was leaking I would not use them
@amgonzalez429
@amgonzalez429 Жыл бұрын
So your company has used them for about a year and we have had some failures. Now don’t get me wrong i have had some brazing jobs leak too but the main reason we stopped using them is because sometimes the 3/8 fittings don’t grip and slip of right off the rip. We now use RLS. I like the idea just didn’t seam worth the risk.
@rafaeljaquez9214
@rafaeljaquez9214 4 жыл бұрын
I would like to see if they hold after years of temp changes and also the elements specially direct sun light during summer days and chilly nights Call me old school but I’ll stick to brazing
@lordjaashin
@lordjaashin 3 жыл бұрын
go with soft solder like stay brite 8. brazing weakens the copper pipeline. it even works on r410a systems
@SteveNeighbor
@SteveNeighbor 3 жыл бұрын
@knowitall - You keep mentioning how nitrogen pressure rises with temperature. Are there some gasses that don't?
@markmagtech
@markmagtech 4 жыл бұрын
Certainly reminds me of the Shark Bite plumbing fittings.. which are quite handy in a pinch in emergency situations.. but would not trust them in a pipe that sees any pressures over 100 PSI. I can't see using these Zoom Lock fittings on larger systems (5 tons and above). And are we not phasing out 410a anyway? Where were these fittings 10 years ago..
@Parabellum-X
@Parabellum-X 2 жыл бұрын
That 'scratch pad' is called Scotch Brite. Also, using the removal tools are pretty much the same as the removal tools that are used with the Sharkbite fittings. The only difference I've noticed is that the little orange plastic removal tools for the Sharkbite fittings are a pain in the @$$ to use, because they actually hurt my fingers when using them, whereas the ones for the ZoomLock don't.
@HVACKnowItAll
@HVACKnowItAll 2 жыл бұрын
Scotch Brite is a brand name. Not all scratch pads are Scotch Brite.
@arthurbrown4427
@arthurbrown4427 3 жыл бұрын
Great video & clear audio. How has the pressure rig held up over the last 2 months? Did you end up manipulating/twisting the fittings once it was pressurized?
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
Yes it's much harder to twist once pressurized. It was still holding up about 3 weeks after. Then I needed my gauges back and took them off.
@alross18058
@alross18058 3 жыл бұрын
Elbows are tight . Restrictions? Should make longer radius elbows
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
I agree, they should!
@mrdan2898
@mrdan2898 2 жыл бұрын
What's the lifespan of these? I can see that there is a rubber gasket inside. Once the rubber gasket dies, so does the fitting. I know these may be easier to use, but is welding really that much harder to perform for a permanent connection?
@quintend1465
@quintend1465 4 жыл бұрын
Do you not cap off your copper rolls, I was always taught to put a cap or tape over the end so dust and debris does not get in it, I see you have it pointing down so chances are not much will get in there
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Because they're hanging nothing is getting in accepted air and moisture, tape won't solve that though haha
@jakem117
@jakem117 4 жыл бұрын
No matter the case, protecting your copper pipe is critical. If not, at least blow it out with nitro before using it. You wouldn't believe the buildup of material from just sitting in a van for a while. I use 5/16" for refrigeration, buy it in a 50' roll. After a while what's left gets stuff in it if it's not capped off. I buy my caps at a local hardware store
@dmiestercommkitchentech3043
@dmiestercommkitchentech3043 4 жыл бұрын
Spiders can and will lay eggs in copper hanging like that so the statement nothing is getting in there except air or moisture is not correct and for someone with the screen name HVAC know it all I would expect better this coming from a fellow know it all also you did not show in you video the outside deburring and in the video you can clearly see metal sticking out after you reamed the inside and then when you show the connection the outside of the tubing is deburred WHY and when did you debur the outside was it because when you were practicing you discovered that if it is not prepared properly then it will damage the fitting ie.. tear into the sleeve or rubber ring. So moral of the story is protect you copper properly by preparing properly all tools and copper tubing is tool
@channelcatchaser9426
@channelcatchaser9426 4 жыл бұрын
My supplier has them under different name
@genepierson1728
@genepierson1728 2 жыл бұрын
Thanks for sharing, this video is over a year old. Do you still like these and recommend them? Also, these are rated for pulling a vacuum too, right? And are the o-rings expected to make it to 20 years or 25 years? Or at least 15 or 10, any idea?
@HVACKnowItAll
@HVACKnowItAll 2 жыл бұрын
Only way to know is to put one in service and watch it. They're new so no one can tell if 25 years is a thing or not.
@genepierson1728
@genepierson1728 2 жыл бұрын
Good point. It's worth the risk for some jobs I think.
@randymiller3583
@randymiller3583 2 жыл бұрын
Where can you buy these ? Amazon?
@Comcom8800
@Comcom8800 4 жыл бұрын
What’s the difference in optimized and not optimized for 410?
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Higher pressure rating and they are non removable
@henryalcocer5127
@henryalcocer5127 3 жыл бұрын
Can we do copper to aluminum?
@kevincawann
@kevincawann Жыл бұрын
Do they make them them flare ends ?
@StPaulToRomans
@StPaulToRomans 3 жыл бұрын
How the depth can be measured without that tool? I have 1/4 and 3/8 pipes to connect.
@1000tomandben
@1000tomandben 4 жыл бұрын
Nice sweatshirt, where’s your Bluon hat?🤔😂😂
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Thanks haha
@AVR-hf1rl
@AVR-hf1rl 3 жыл бұрын
How come they do not make 5/16
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
Not sure
@jamesdeanvegas
@jamesdeanvegas 2 жыл бұрын
Exact video I was looking for I was just at a supply house and was like that’s cool but skeptical for obvious reasons. I wanna use it for the aluminum to copper fitting from the new home builders using aluminum. Seems like every single one I go to the brazing sucks and always leaks. Thanks for the vid
@I_AriesMan
@I_AriesMan 4 жыл бұрын
Man u have a Ford Transit 150? What engine does it have? GAaoline or Turbo Diesel?
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Gas
@brandonharned4002
@brandonharned4002 Жыл бұрын
Can you push the pipe too far?
@jimclarke734
@jimclarke734 4 жыл бұрын
How long is the warranty on the fittings?
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Looks like 10 years on 410a and 5 for the removable type
@jimclarke734
@jimclarke734 4 жыл бұрын
@@HVACKnowItAll wooh that’s impressive for 410a. I’d still give a proper braze a lot longer than 10 years but that is still a serious warranty. Longer than most Ac manufacturers
@joeboxter3635
@joeboxter3635 3 жыл бұрын
R134a possible?
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
I believe so, just use due diligence and ensure you keep an eye.
@gordonpotts753
@gordonpotts753 Жыл бұрын
My skepticism lies in the fact that soft tubing isn't always round.
@Conflict1922
@Conflict1922 3 жыл бұрын
I wanted to try one of these for a coil change out, and I couldn't find them, I emailed Parker and they said they aren't approved yet in Canada :(
@abdorakeebnaji1527
@abdorakeebnaji1527 3 жыл бұрын
Vary nice video 👍
@jaysonperez1984
@jaysonperez1984 2 жыл бұрын
Thanks for the content ! Excellent job of explaining pressure drop / rise vs size or “ real Estate “ of system . Looking forward to viewing more of your instructional videos . Jayson Perez B&G Piping Company UA local 777 P1, MG1 , S2
@TerryRGraham
@TerryRGraham 3 жыл бұрын
Sure would suck if it leaked with today's refrigerant prices and you end up eating that cost for a warranty. R- 22 at 1000.00 and 410A at 350.00.
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
Yes it would, if i uses these in the field it would be tested on smaller stuff.
@jamesboyd6174
@jamesboyd6174 3 жыл бұрын
2:48 Thats what she said
@rickrojas9564
@rickrojas9564 3 жыл бұрын
Same amount of work as brazing if not more
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
Think outside the box, it depends really. There are some buildings that take a while to gain burn permits if you can even get one on the fly for a repair. Then there are some that have a fire watch afterwards. There are many other factors here where if the fitting does hold over time it could be a benefit. Would I perform an install with these, probably not but in a jam or certain environment, they may prove useful
@Papi-Oh
@Papi-Oh 3 жыл бұрын
Tyson man, if you only knew the red tape, permit fees, certification, not to mention all the safety tools and personels you're required just to get that brazing. As Thannos said," all of that for a drop of blood."
@joecraigslist9467
@joecraigslist9467 3 жыл бұрын
These could be great for the non professional DIYer who can't braze and doesn't have the equipment. Now I can replace my evap coil.
@armandotorres626
@armandotorres626 4 жыл бұрын
Just can't find it in myself to put my trust into these quick fix push on fittings...
@dennishala1272
@dennishala1272 3 жыл бұрын
I'm in the middle of watching this and BAM an add pops up. Now I don't know about u but I think that's rude. LETS BAN ADS
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
Lol, then KZbin would fail, that's how we gain from our hard work outline together vids.
@smoothsteviegful
@smoothsteviegful 3 жыл бұрын
Stay away from these fittings if you like pressure testing 2-3 times then end up brazing not worth the wasted time and fustration.
@HVACKnowItAll
@HVACKnowItAll 3 жыл бұрын
I mean they held pressure for days in my basement
@lordjaashin
@lordjaashin 3 жыл бұрын
@@HVACKnowItAll but there is expansion and contraction in a working HVAC system that is very different to checking the durability of these fitments in the basement (stable environment)
@andrewcardenas8631
@andrewcardenas8631 2 жыл бұрын
These are trash, the copper has to be perfectly aligned in order for it to seal.
@andrewsteele1774
@andrewsteele1774 11 ай бұрын
Sorry but dis agree with these fittings, you should however go to the press fit technology with RLS, I know it is expensive but the new future.
@HVACKnowItAll
@HVACKnowItAll 11 ай бұрын
I use RLS
@clisky
@clisky 2 жыл бұрын
Hard radius is trash on refridgerant
@jervislove366
@jervislove366 3 жыл бұрын
Just call it a shark bite
@jonnymac31
@jonnymac31 4 жыл бұрын
Its hard enough keeping systems leak free over the long haul without throwing stuff like this in the mix.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Stuff like this will be the future
@5822huron
@5822huron 4 жыл бұрын
@@HVACKnowItAll the future is now!
@SeanMackBuffaloStyle
@SeanMackBuffaloStyle 4 жыл бұрын
This product is dumb. All this does is bring in the DIY people into our trade. Any way to save money today....like we don't have enough crap to worry about doing our craft. If I see in the field, I'm cutting it out. Why not install flare elbows on every 90 degree or coupling? Because it wouldn't make any sense just like this crap.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
Have you worked in buildings or environments where lighting a torch is not allowed? Prodcucts like these are usually born out of necessity and if they work, can be a handy tool in certain applications. A confident tech should never fear a DIYer, they lack execution.
@SeanMackBuffaloStyle
@SeanMackBuffaloStyle 4 жыл бұрын
@@HVACKnowItAll to answer your question, yes in research labs and hospital with oxygen lines nearby, which is not normal situation for most techs. In the commercial and industrial refrigeration world, All this product is, is an excuse to be lazy. When you have a refrigerant leak, will the fitting manufacturer cover the refrigerant and labor bill? 100 percent No. Or how about the cost of the fitting and adding another fitting because your short on copper to cut out the old fitting? 100 percent No.
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
No one is telling anyone to go buck wild on these, this video is a demo of the product. All I'm saying is they may come in handy in certain applications.
@grimeyhonkyracing3938
@grimeyhonkyracing3938 4 жыл бұрын
@@HVACKnowItAll im going buck wild
@HVACKnowItAll
@HVACKnowItAll 4 жыл бұрын
@@grimeyhonkyracing3938 let me know how it goes
@baitcasterdisaster8981
@baitcasterdisaster8981 4 жыл бұрын
That looks horrible to me. I enjoy brazing and I’m not gonna stop , especially to use garbage like this that I don’t trust and never will. Brazing is not hard to do at all and it’s quite fun to me, and if done RIGHT will not leak. Brazing is tested and proven and been around way longer than this trash. That’s just my 2 cents
@yotahoon1421
@yotahoon1421 3 жыл бұрын
I also enjoy brazing
@user-si3ih5hj3n
@user-si3ih5hj3n 2 ай бұрын
These are junk
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 155 М.
How To Connect Refrigerant Lines Without BRAZING!! | RLS Press Tool
27:09
Andro, ELMAN, TONI, MONA - Зари (Official Audio)
2:53
RAAVA MUSIC
Рет қаралды 8 МЛН
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН
SLIDE #shortssprintbrasil
0:31
Natan por Aí
Рет қаралды 49 МЛН
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН
Parker Sporlan Demonstrates ZoomLock Fittings
8:25
HVAC School
Рет қаралды 2,1 М.
4 MISTAKES Everyone Makes When Using COMPRESSION FITTINGS
10:49
plumberparts
Рет қаралды 902 М.
Using Zoom Lock On a Service Valve
7:45
John Israel HVAC
Рет қаралды 168 М.
Brazing Alternatives For The HVAC/R Tech - Requires No Nitrogen
9:55
HVAC Know It All
Рет қаралды 28 М.
Is Your A/C Unit About To Die? This Tool Doesn't Lie
10:03
The DIY HVAC Guy
Рет қаралды 269 М.
HVAC 087 F Connections part 6 Quick Connect Push To Connect Fittings
10:28
Love2HVAC with Ty Branaman
Рет қаралды 16 М.
10 Reasons Why A Mini Split Flare May Be Leaking Refrigerant!
18:15
AC Service Tech LLC
Рет қаралды 754 М.
Andro, ELMAN, TONI, MONA - Зари (Official Audio)
2:53
RAAVA MUSIC
Рет қаралды 8 МЛН