What are Screen-printed electrodes and which electrode should I choose?

  Рет қаралды 4,041

PalmSens

PalmSens

Күн бұрын

Пікірлер: 7
@muhsinali8386
@muhsinali8386 8 ай бұрын
your videos are so helpful and would like to know is there any option for calculating capacitive current/integration of capacitive area calculation from a CV using PS trace or any alternative.
@PalmSens
@PalmSens 8 ай бұрын
Dear Muhsinali, That is not an easy question. Digital potentiostats work in discrete potential steps, which makes their ramps always a staircase if you zoom in sufficiently. This way of measuring has an in-built supression of capacitive current or other very fast processes. The shorter the interval time, the closer the measured capacitive current will be to the real current. The whole effect is well documented by brands that have a true-linear module, to demonstrate their advantages. This is why CV isn't a great method to measure capacitive charging currents. You can use a potential step method. You can use MultiStep Amperometry or Fast Amperometry, but unfortunately there is a short overhead time, nefore the step, so for a fast capacitor this could have some impact. We are working on improving this. We recommend Method, if you have an EmStat4 or EmStat Pico. This way you can perform the whole method on the board of the potentiostat, without any overhead time.
@pratyushmohapatra8184
@pratyushmohapatra8184 5 ай бұрын
Good morning sir Could you help me out for designing my own screen printed electrode? I am working to design a screen printed electrode using metal deposition. My analyte is Hydrogen peroxide Working electrode- Ag metal Counter electrode- Ag metal Reference electrode- Ag/AgCl Will this combination work? If not what kind of modification do I need to implement so that it will work nice?
@PalmSens
@PalmSens 4 ай бұрын
Dear Pratyush Mohapatra, thanks for your inquiry. Here at PalmSens we focus on instrumentation and software for research and OEM customers, we do not manufacture (screen printed) electrodes or accessories ourselves. Among our partners, I don't recall any of them with ready products for peroxide detection. Nevertheless, you can ask them, we provide a complete list of the companies we collaborate with here www.palmsens.com/custom-sensor-development/#section-3
@swarnadasari9681
@swarnadasari9681 10 ай бұрын
Is a SPE compatable with VSP 300 Biologic work-station? What can be used as a connector in this case? If you can suggest any... Thanks in advance
@PalmSens
@PalmSens 10 ай бұрын
Dear Swarnadasari9681, We would prefer that you are using PalmSens potentiostats. They have multiple options to connect electrode, SPEs or classical. However, potentiostats, no matter the brand, don't care what electrodes are connected, they will just apply the potential and measure the resulting current. All you need is a connection between your potentiostat and the electrodes. We offer multiple options for SPE adaptors, that are also suitable for other brands. You can find them here: www.palmsens.com/products/sensors/sensor-connection/? If you are looking for a very straight forward option we recommend our SPE connector (2 mm) www.palmsens.com/product/sensor-connector/?
@swarnadasari9681
@swarnadasari9681 10 ай бұрын
@@PalmSens Thanks a lot for your suggestions.
ДЕНЬ УЧИТЕЛЯ В ШКОЛЕ
01:00
SIDELNIKOVVV
Рет қаралды 4 МЛН
Крутой фокус + секрет! #shorts
00:10
Роман Magic
Рет қаралды 40 МЛН
What is a potentiostat and how to connect a potentiostat?
7:32
Here's Everything You Need To Start Screen Printing?
15:26
I Like To Make Stuff
Рет қаралды 443 М.
Screen Print line for Flexible/Printed Electronics
1:08
Nanotechnology, Danish Technological Institute
Рет қаралды 6 М.
Voltammetric Electrodes
10:25
Gary Mabbott
Рет қаралды 89 М.
Aluminum and Mercury
8:50
NileRed
Рет қаралды 52 МЛН
Former Spy Ranks Amazon Spy Devices | DEEP X
13:05
People Are Deep
Рет қаралды 315 М.
When to use or not use cyclic voltammetry in biosensor development
19:59