Follow RealPars on Instagram instagram.com/realparsdotcom/ for daily practical tips and tricks on Industrial automation and electrical engineering topics.
@adammustapha415010 ай бұрын
You are doing a very great job with your content. i have few questions to ask about S7-1214C PLC 1. If an S7-1214 Siemens PLC has several LED indicators that can be used to verify if the processor is operating correctly and the Maintenance LED is flashing yellow and there is no memory card. What does this mean? 2. IF An S7-1214 stopped controlling the machine. The STOP/RUN indicator is yellow and the ERROR LED is red. What’s wrong? 3. A controlLogix 1756 processor has a flashing green I/O LED, ehat does this mean and ehat should you do to troubleshoot?
@realpars10 ай бұрын
Hi Adam, Thank you for your insightful questions. While they are excellent queries, they fall outside the scope of our current lesson platform. If you're experiencing issues with your LEDs flashing, there could be a variety of factors at play. Fortunately, assistance is available! Your local Siemens representative can offer valuable support. Siemens provides a comprehensive website and blog equipped with troubleshooting guides and technical manuals to address your needs. Much of their online troubleshooting assistance is complimentary. However, there may be charges for direct technical consultations. For information specific to Siemens PLCs, please visit the following link support.industry.siemens.com/cs/document/109744173/documentation-for-simatic-controller?dti=0&lc=en-WW Here is your 1756 processor manual too: literature.rockwellautomation.com/idc/groups/literature/documents/um/1756-um001_-en-p.pdf
@adammustapha415010 ай бұрын
@@realpars Thank you 👊💯
@yidingji75523 жыл бұрын
This channel is definitely like a "mountain full of treasures". For those who aim to learn engineering automation, go ahead and take a look, strongly recommended!
@realpars3 жыл бұрын
Hi Yiding! Thanks a lot for your kind compliment! We are always extremely happy to hear such positive feedback! If you ever have any questions, feel free to reach out to us. Happy learning!
@mouizimran10325 жыл бұрын
Hi Sir, the video was very beneficial. Kindly make video lesson on I/O modules. 1. DI Module, 2. AI Module 3. DO 4. AO Their working, internal electronic circuitary, terminal details, how to force them, how to wire them Different AI modules (2 wire, 3 wire,4 wire)
@realpars5 жыл бұрын
Hi Mouiz, Thanks for the topic suggestion, I will definitely go ahead and forward this to our creator team. Happy learning!
@chowtina866610 ай бұрын
Hi Sir, the video was very beneficial.tks so much
@DrReginaldFinleySr Жыл бұрын
That's the How it's Made guy's voice. 🙂 Excellent video. Thank you for sharing.
@realpars Жыл бұрын
Glad you enjoyed it!
@Facemix4 жыл бұрын
Hi guys! Can you create a video explaining the main difference between s7 1200 and s7 1500? It would help a lot! Anyway, you're doing a fantastic job!
@realpars4 жыл бұрын
Hey Facemix! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@christianadanparedescarden38777 ай бұрын
I´m so glad to found your channel, it´s amazing!
@realpars7 ай бұрын
Glad to hear that! Thank you very much
@RicardoCosta-es7cv4 жыл бұрын
This channel it's very useful for me !!! TKS guys
@realpars4 жыл бұрын
Thanks for your support, Ricardo!
@samirghedjati40243 жыл бұрын
Thank you realpars team, would you mind make a video about Siemens PLCs evolution? Also DCS? Thank you in advance.
@realpars3 жыл бұрын
Hi Samir! Thanks for your comment and your suggestion. I will pass this on to our course developers! Regarding DCS, we do have quite some video courses on that, feel free to check those out over here kzbin.info?search_query=dcs+realpars Thanks for sharing and happy learning!
@murugesanpilavilai95304 жыл бұрын
Well said. S7-1500 widely suport the data with out error and speed transmition. Thanks a lot for the post.
@realpars4 жыл бұрын
Thanks for your support, Murugesan! Great to hear that.
@danstaifer20285 жыл бұрын
What about the 1200?
@haaszjanos13243 жыл бұрын
@He who must not be named not just a little, it is mostly used for home applications
@patrioticlion97735 жыл бұрын
Great content! Love this channel!
@realpars5 жыл бұрын
Great to hear! Thanks a lot!
@patrioticlion97735 жыл бұрын
@@realpars You're welcome.
@melquiadesdelgadoramirez6805 жыл бұрын
Nice video and precise information about both models of PLCs available from Siemens. Thanks Realpars for this useful material.
@realpars5 жыл бұрын
Happy to hear that, thanks a lot!
@rajuhassani14164 жыл бұрын
Add more videos on field instruments , Components of Marshalling cabinet , System Cabinet , Explain the FGS system also
@realpars4 жыл бұрын
Hi Raju! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@abdoulayediao5433 Жыл бұрын
Do you have to rewrite the logics when converting from 300 to 1500?
@realpars Жыл бұрын
Hello Abdoulaye Fara Diaw, Thank you for your question. The answer to your question is maybe. Depending on how complicated your S7-300 logic is FB, OB, FC and DB blocks are, you might have to rewrite some of the logic and configure your hardware too. I am attaching 2 links from the Siemens industrial support website you should be looking at. Happy learning! support.industry.siemens.com/cs/document/62100731/what-are-the-requirements-for-migrating-a-step-7-v5-x-project-to-step-7-professional-(tia-portal)-?dti=0&lc=en-US support.industry.siemens.com/cs/document/109478811/migration-guide-simatic-s7-300-400-to-simatic-s7-1500?dti=0&lc=en-WW
@zinou88885 жыл бұрын
Please make course about MMS communication protocol
@realpars5 жыл бұрын
Thanks for the topic suggestion! I will definitely forward this to our creator team.
@erickontiveroslara2095 жыл бұрын
Could it be possible to have a series of videos bout AS-i bus?
@realpars5 жыл бұрын
Thansk for the topic suggesiton, Erick! I will pass it on to our creator team.
@ejazasif97563 жыл бұрын
Yes please I am also looking for a deep series of videos about As-i. It would be better if Its from a real pars.
@levanhuan39325 жыл бұрын
What is the difference about programing s7 200 and s7 300. Could you make a video about that.please!
@realpars5 жыл бұрын
Hi Huan! Thanks for the topic suggestion, I will definitely go ahead and forward this to our creator team. Happy learning!
@ardentdfender41165 жыл бұрын
Solid video and in visual animation!
@realpars5 жыл бұрын
Great to hear! Thanks a lot, Ardent!
@ThuanAutomation4 жыл бұрын
The video is very useful, thanks to you, I know the difference between these 2 types of plc
@realpars4 жыл бұрын
That is great! Happy learning!
@spawn2qc2175 жыл бұрын
2:47 Standard, compact (C), fail-safe (F) and you could add technology (T) version. Those have more motion ressources. There is also the new redundant (R) and high availability (H) S7-1500, but R and H doesn't exist in the S7-300 platform. You had to go with S7-400H "in the past".
@realpars5 жыл бұрын
You can see the other types of these CPUs on its relevant blog post here: realpars.com/S7-300-versus-S7-1500/
@danliviu1795 жыл бұрын
A video for analog input scale on Step7 simatic manager with STL? Please, or do you have this as a course? Thx
@realpars5 жыл бұрын
Hi Dan, Thanks for your comment! We do have a couple of course videos in our course library covering Analog Input. bit.ly/31Ypl1p Happy learning!
@qzorn44403 жыл бұрын
nice, how does this compare to the rockwell plc stuff...? thanks.
@realpars3 жыл бұрын
Thanks for your comment! Great question, that would make for an interesting topic suggestion for a future video course. I will go ahead and pass this on to our course developers. Thanks for sharing!
@thassioam5 жыл бұрын
Why there’s just 31 nodes to connect using Profinet?
@avevaedgevideos783675 жыл бұрын
thassioam 5 bits only on the address part of the data stream.
@excellentknives5 жыл бұрын
Very Informative ❤
@realpars5 жыл бұрын
Thank you!
@rhythmandacoustics5 жыл бұрын
That's some fancy stuff you got there!
@voornaamachternaam35024 жыл бұрын
shitty programming, expensive, bad software, schneider electric is way better !! i use every brand except siemens
@Josempe14 жыл бұрын
Do you have some video about PLC-S7400?
@realpars4 жыл бұрын
The S7-400 is typically used as an AS node in PCS7. We have a new series that is just starting at Realpars.com covering PCS7, which uses a CPU 416-2 DP processor. Come check it out!
@Josempe14 жыл бұрын
@@realpars Thank you. I would like more information about AS node in PCS7
@222amonra2 жыл бұрын
So it seems like the only difference is 1ns processing time which is really not needed for 90% of the applications and the built in display. Nothing is said about the differences in programming with TIA portal and Simatic Manager. It's left open, what the price really is for a basic configuration say 64 I/O's and 8 axes for example. In my opinion it is usually the programmers skills and Know-How to determine which PLC and programming environment is selected.
@realpars2 жыл бұрын
There are a number of other differences, including an expanded instruction set with the S7-1500, built-in OPC-UA support, built-in web-server, better diagnostics, auto-tuning PID, and motion control support, just to name a few. And yes, the increased CPU speed is not really a big benefit unless you are doing high-speed operations, such as packing lines or fillers. As far as programming packages, SIMATIC Manager cannot be used for the S7-1200 or S7-1500. But TIA Portal Professional can be used with any S7 CPU, making the the best choice for programming any Siemens PLC. The S7-1500 has a pretty high price tag for small systems, so for a 64-I/O system, an S7-1200 can be economical (
@jonathanchristian82944 жыл бұрын
can i use new version of tia portal to program siemens s7-300 ?
@realpars4 жыл бұрын
YES! You will need the TIA Portal Professional version. The Basic version can be used for programming S7-1200 CPU's only.
@nguyennguyen-hd2ce5 жыл бұрын
Siemens said : " we will not support S7-300 , s7-400 in the future " . Last time i heard is 5 year ago
@MPI10005 жыл бұрын
Hell, I've got a ~$3M machine at work that got handed over 3 months ago that has a 319-2F/PN in it... And every CNC machine with a Siemens Sinumerik control still comes with a 300. 2020 for the NCUs with 1500s was what I heard last year. We'll see, I guess.
@monstersolution61065 жыл бұрын
Now almost the time to replace S7-400 because S7-1500 have redundancy feature.
@ahmedmetwally49115 жыл бұрын
Thanks for you best creative team ever
@realpars5 жыл бұрын
Great to hear that! Thanks a lot!
@Sujananaidu24944 жыл бұрын
Please make video about closed loop controller and how to program with encoder with HMI traverse fuctions
@realpars4 жыл бұрын
Thanks for the topic suggestion, Selva! I will definitely go ahead and forward this to our creator team. Happy learning!
@venkatr56985 жыл бұрын
plz help me simulation button not showing (S7-300)
@realpars5 жыл бұрын
In order to be able to select the Simulation button, the program you would like to download needs to be selected. Click on the PLC in the project tree. If the Start Simulation button is not selectable, try recompiling the hardware configuration and then recompile the software configuration. You should be able to start the simulation at this point. If not, make sure the S7-PLCSIM program is installed correctly. The best way to do this is to start the simulation program and see if it will fully boot up to the CPU status window. Also, the S7-300 series of CPU's requires S7-PLCSIM v5.4 or earlier. The latest PLCSIM programs (v12, v14, v15) only work with the S7-1200 and S7-1500 CPU's.
@automationwithmukeshdayama61005 жыл бұрын
Really valuable video
@realpars5 жыл бұрын
Thank you, Mukesh!
@nkelectricalautomations5 жыл бұрын
your videos are great and quite easily understandable .... can you make videos on logosoft comfort v8
@realpars5 жыл бұрын
Hey Susant! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@jimbass9243 жыл бұрын
Great video!!!
@realpars3 жыл бұрын
Thank you!
@Apdepote2 жыл бұрын
My company use s7-1500 but in i/o module is 50 .
@iran_siemens5 жыл бұрын
hi dear realpars very good thanks
@realpars5 жыл бұрын
You are very welcome! Happy learning!
@jardadvorak27325 жыл бұрын
Try to migrate s7-300 to s7-1500, where is fb285 for control drives used. Absolutely hell.
@EngASax5 жыл бұрын
What a great video thank you so much
@realpars5 жыл бұрын
Happy learning! :)
@vadpro39765 ай бұрын
Thanks!
@realpars5 ай бұрын
Our pleasure!
@tomaslarsen78144 жыл бұрын
A big difference , is how a scada polls data from s 1500.
@tomaslarsen78144 жыл бұрын
1500 write data async
@tomaslarsen78144 жыл бұрын
300, or 400 writes data at end scan
@_Iokanaan_Marusidze_5 жыл бұрын
Thanks a lot !
@realpars5 жыл бұрын
You are very welcome, Alexandr!
@samirfayez90285 жыл бұрын
Really good
@realpars5 жыл бұрын
Thank you!
@derina.maleek94085 жыл бұрын
Thank
@otabektillavayev33092 жыл бұрын
Thanks million
@realpars2 жыл бұрын
You're very welcome!
@otabektillavayev33092 жыл бұрын
I am live In Uzbekistan.Are your have ofice in Uzbekistan
@karinaandrea3962 жыл бұрын
Thanks a lot n.n
@realpars2 жыл бұрын
You're welcome!
@jmbcrp10107 ай бұрын
I will never play along with the monopoly of Allen Bradley and Siemens, whoever wants to make these companies richer welcome, I have had projects for more than twenty years working and making upgrades with PLCs from different brands, they do the same!!! More economical!! And even in some cases, better functions such as Rest API, OPC UA, it seems like a robbery to me that just by checking a box on the portal they charge you 1000 dollars just to enable OPC UA, that's it!!
@K.alnajdi934 жыл бұрын
I hope you will add the Arabic language I hope you will add Arabic to the translation of the video
@realpars4 жыл бұрын
Hey! Thanks for your comment! We currently only provide our course videos in English, you are always able to turn on the English subtitles as that might make it a bit easier for you. Our apologies for any inconvenience! Happy learning!
@ВладимирВикторовичЖелтобрюхов5 жыл бұрын
S7-1500 - гавно TIA Portal - гавно
@angelrivera31922 ай бұрын
Redundancy ?😑🤔 I don’t like this video but I can push the dislike bottom because affect my preferences algorithm and you’re too important in this field
@realpars2 ай бұрын
Thank you for your feedback! We're sorry this video didn't meet your expectations and appreciate your support. If you have any suggestions, we’d love to hear them.