What is a single acting and double acting hydraulic hand pump?

  Рет қаралды 132,909

Sarum Hydraulics

Sarum Hydraulics

Күн бұрын

Пікірлер: 20
@user-op6uv5bx1r
@user-op6uv5bx1r 11 ай бұрын
Thanks! excellent animation In any case, the liquid in the container is not under pressure as seen - It is always blue
@oscarpena314
@oscarpena314 Жыл бұрын
On the double acting pump. Why is the outlet check valve required? Its open in both the up and down stroke. Is it just a protection method against backflow? The intermediary check valve seems to be able to also protect the tank.
@johnfoster8624
@johnfoster8624 Жыл бұрын
Good afternoon Oscar, That's a good question. I think I have seen pumps without the outlet non return valve. I think one of the Italian volume market pumps doesn't have it. We have put in this extra check valve for 40 years simply to provide that extra security. My instinct is to put it in for that reason. Thank you for the interest in our product.
@isidoropascualmolina7381
@isidoropascualmolina7381 Жыл бұрын
Hi there. In a double acting pump, if I eliminate the intermediate valve, it performs as single action? Thank you
@majk6888
@majk6888 Жыл бұрын
where I can get it in KSA
@puregold394
@puregold394 2 жыл бұрын
shits crazy
@munilalkumar9837
@munilalkumar9837 4 жыл бұрын
Manilal kumar the ye pamp chahiy
@kageyame
@kageyame 5 жыл бұрын
This animation is wrong, there no reason for the downward stroke to generate pressure to pump the fluid.
@johnfoster8624
@johnfoster8624 5 жыл бұрын
Thank you Kageyame. On a single acting pump, you are pulling in a shot of fluid from the inlet check valve in the base. The outlet check on the side is shut. The down stroke puts a solid rod into a chamber of fluid and expels it from the outlet check on the side. The double acting pump pulls a double volume slug of fluid in below the piston on the upstroke, expelling the fluid above the piston out through the outlet check valve. The piston check is shut. Now on the down stroke, it is almost working like a single acting pump. The check in the piston allows fluid up and the net effect is the volume of the rod that forces a slug of fluid out of the outlet check valve. If the area of the rod is half that of the piston, the flow on the up stroke is the same as the down stroke. That's how I see a double acting pump. Sorry, I can't see why the animation is wrong. Are you looking at the downstroke on the double acting pump? If so, think of it as a pot of fluid and you are simply pushing a displacer into it. That amount will be pushed out. Happy to discuss further.
@kageyame
@kageyame 5 жыл бұрын
​@@johnfoster8624 Sorry, my bad It was hard to visualize by the animation alone, but from what you said, the upper layer have half the capacity of the bottom layer, so in the end the full stoke in both pumps send the same amount of fluid outwards, but the double action distribute the load in upwards and downwards strokes, correct?
@sarumhydraulics1386
@sarumhydraulics1386 5 жыл бұрын
@@kageyame , thank you for the message. Yes, you are right. You expel the same amount of fluid on the up and down strokes. The load on the rod is the same on up and down.
@udaykits1
@udaykits1 5 жыл бұрын
@@sarumhydraulics1386 by the way, in terms of efficiency which one is more efficient, a single acting or a double acting when connected to an electrically driven motor?
@sarumhydraulics1386
@sarumhydraulics1386 5 жыл бұрын
@@udaykits1, thank you for the question. Whichever cylinder you use, you will only get out what you put in. Use the formula Force= Pressure x Area. If you are using the full bore side of the cylinder, the area may well be the same so the force will be the same. If you go for a double acting design, the extra pipework and valve components will give rise to some loss of energy, we would have thought. We would generally say "try to use a single acting cylinder if you can because it is simple. Some applications will need double acting in order to work, so that is what you will have to use." On your "efficiency" question it is also worth noting that using a mass or spring return to return a single acting cylinder is only stored energy. The single acting ram needs extra pressure to drive it out on the pressure stroke then that energy is used to return it. An electric pump won't be generating pressure for the return stroke for a single acting ram.
#Be creative with your work# Make a Hydraulic Hand Pump
10:05
بيت الهيدروليك & Hydraulic house
Рет қаралды 63 М.
Unveiling my winning secret to defeating Maxim!😎| Free Fire Official
00:14
Garena Free Fire Global
Рет қаралды 11 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 17 МЛН
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 17 МЛН
How a hydraulic jack works
4:03
Chava Tarin
Рет қаралды 1,4 МЛН
How a hand pump works
2:51
Engine On
Рет қаралды 2,8 МЛН
Pneumatic Cylinder:  How Does It Work?
3:00
Hydraulic and pneumatic systems
Рет қаралды 188 М.
LÀM BƠM TAY THỦY LỰC
5:45
Thủy lực 88
Рет қаралды 47 М.
How a hydraulic jack works
8:11
Deconstructed
Рет қаралды 1,3 МЛН
Inside the Checkball Hydraulic Pump: Design and Operating Advantages
1:52
Learn how to make a hydraulic fluid reservoir
3:44
Sarum Hydraulics
Рет қаралды 11 М.