Your videos are done so well thanks for so much information had to hit the subscribe button 🍻
@gregvancom Жыл бұрын
Welcome aboard!
@GregoryGuay5 ай бұрын
In this example, can you run a horizontal from toilet to sink under the roof deck in order to reduce to just one roof penetration ?
@joeduffy33765 күн бұрын
Can you run a washing machine tap through a p trap and then directly to the 4” vertical pipe to act and drain and vent? Looking to finish a basement with one of those for a washing machine drain and another for a water softener drain
@cornpop7805 Жыл бұрын
I had a situation where the only place I could vent the toilet was from behind. It worked quite well, but I couldn't find anything written it the IPC, the UPC, or anywhere on the internet, which described this as being an option. I'm glad to finally see it referenced somewhere!
@timmanson6040 Жыл бұрын
because its not. you cant put a drain into the trap arm of the toilet. best case is to paralell the drain from the sink and tie it down stream of the vent inlet.
@gregvancom Жыл бұрын
Glad to help.
@justayoungplumber7776 ай бұрын
Thank you very much for sharing a descriptive lesson as this.
@gregvancom6 ай бұрын
You're very welcome!
@georgereycraft48569 ай бұрын
In the last example, could the wet vent be 2 inch, from the 3 inch combo wye?
@jimclary-f9l9 ай бұрын
Thanks ,my question is if the stack is with in 6 ft of the fixtures do you need to vent them? Small bathroom
@gregvancom9 ай бұрын
Every fixture needs a vent.
@4everhdt Жыл бұрын
Great video and explanation. Thanks 😊
@gregvancom Жыл бұрын
Glad it was helpful!
@ggc7318 Жыл бұрын
Thanks for the lesson.
@gregvancom Жыл бұрын
You're welcome and thanks for watching.
@mbn567m Жыл бұрын
Do you have a good example for using 4 in. x 4 in. x 4 in. x 2 in. x 2 in. (Nibco 4870). I imagine is it can combine lavatory, toilet and tub drain and give vertical vent at the same time.
@gregvancom Жыл бұрын
I don't think so. You can check the plumbing section at our website, it might provide some other designs that will work.
@joeteno49132 ай бұрын
On the last example don’t you have to turn the wyefrom the toilet about 45 degrees so the toilet isn’t dropping down into the air stream of the wet vent behind it
@hovgh1347 Жыл бұрын
is this for los angeles?
@gregvancom Жыл бұрын
You will need to check with them, but it should work.
@brucestorey917 Жыл бұрын
You cannot vent a toilet in the fashion (horizontally) you have shown at about 4:46 without that vent being a wet vent. With the system you are showing, the vent for the toilet cannot break to horizontal until it is 6” above the flood level of the toilet. In some cases where it is absolutely impossible to vent a toilet or other fixture vertically before reaching the flood level, an inspector may let you do it the way you have shown if you install a cleanout on the vent. But you made no mention of this and your animation does not show a cleanout. You just can’t do it this way without permission and a good reason.
@vicschauberger2737 Жыл бұрын
You are correct . That is dry venting and ,in the event of a blockage , effluent and waste can get stuck in that horizontal branch with no wash out . It can be configured that way if it has a lavy upstream washing it out . In that case it's a wet vent , as you said . Also when horizontal branches are pitched at 1/4" per foot . fluids adhere to the inside of the pipe in a circular , scouring motion leaving the center hollow . Not filled halfway with fluid as this video shows.
@markblaze4909 Жыл бұрын
Why not just use a San tee for the vent you don’t need the wye.
@gregvancom Жыл бұрын
You can, but my thinking is always design pipes for snake cleaning tools, that's why I suggested the combo fitting.
@Stevesbe7 ай бұрын
Hacked up by the plumber?? No way😊
@LightGesture5 ай бұрын
Vertical i just can't see being a good thing. Big tyrd flopping down into the pipe...