Which Type of SPD should you use? ⚡

  Рет қаралды 6,616

Axis Electricals

Axis Electricals

Күн бұрын

Пікірлер: 26
@mk-series584
@mk-series584 7 ай бұрын
Sir, may I know how to order the product
@AxisElectrical
@AxisElectrical 7 ай бұрын
Great to hear from you! 🚀 For a quick response, please email your requirements to sales@axis-india.com. Our engineers are eager to help you. If you prefer, you can also leave your contact details here, and we'll reach out.
@mk-series584
@mk-series584 7 ай бұрын
@@AxisElectrical I had contacted, there is no response to option for order
@AxisElectrical
@AxisElectrical 7 ай бұрын
Apologies for the inconvenience @@mk-series584 You can place your order from our website axis-india.com/product/surge-protection-devices/ Or get in touch with our Sales Manager - Sujith Kumar: +91 73045 49337 📞
@FarhanKhan-zu8rj
@FarhanKhan-zu8rj 22 күн бұрын
Could you please make a video for SPD vs volt protection device?
@YP-zs9wk
@YP-zs9wk 5 ай бұрын
Very good presentation. I have installed the SPD for both L and N with 32A mcb. SPD installed after the consumer unit breaker so hopefully protecting everything after this point.
@AxisElectrical
@AxisElectrical 4 ай бұрын
Thanks! I am glad you liked it!
@lg3053
@lg3053 Ай бұрын
Very good video explanation. Thanks for making it.
@AxisElectrical
@AxisElectrical Ай бұрын
Glad you liked it!
@deepakbhati878
@deepakbhati878 7 ай бұрын
Sir please make a video about high voltage atex test for terminal block.
@AxisElectrical
@AxisElectrical 7 ай бұрын
Thank you for your suggestion Deepak, we will surely plan something around that topic.
@DaveSons
@DaveSons 18 күн бұрын
Hello sir, thanks for the good representation. What rating of SPD suits my load (premises/whole building with total loading of 30Kw)
@AxisElectrical
@AxisElectrical 17 күн бұрын
Hey, SPDs connected in parallel, aren't affected by circuit load. Their effectiveness depends on location and the equipment they protect.
@DaveSons
@DaveSons 17 күн бұрын
I have an electric oven which has a total rating of 28kw, but low voltage tends to disturbs us a lot. As a result, this voltage imbalance most times burn contactors. Would adding an SPD into the installation sort my problem out. If yes, then what size can be suitable. Thanks
@AxisElectrical
@AxisElectrical 17 күн бұрын
​@@DaveSons Voltage imbalance or fluctuation should be addressed using a voltage stabilizer, sized according to your oven's 28kW load. An Type 2 SPD can protect against voltage spikes, but won't solve your low voltage issues.
@DaveSons
@DaveSons 17 күн бұрын
@@AxisElectrical ❤️. Thanks
@freefall_910
@freefall_910 7 күн бұрын
Spd vs Voltage regulators
@AxisElectrical
@AxisElectrical 6 күн бұрын
We will try and make a video on that!
@oladehindepaul8648
@oladehindepaul8648 5 ай бұрын
Sir, please can I connect earth wire from SPD to the lightning arrester ground Earthing pit
@AxisElectrical
@AxisElectrical 5 ай бұрын
SPD earthing and equipment earthing should be common, and as per the standards all the Earth Pits should be interconnected to achieve Equipotentialisation.
@abhaypatel8722
@abhaypatel8722 4 ай бұрын
I saw some video where they saying to put earthing of SPD separate from earthing of rest of connection and earthing of lighting arrester also be different, is this correct , please explain
@jagratahir2132
@jagratahir2132 5 ай бұрын
If we install SPD then won't it result in tripping of the upstream earth fault protective device?
@AxisElectrical
@AxisElectrical 5 ай бұрын
Hi Jagrat, Installing SPD won't result in that, but if SPD undergoes some fault like a short circuit or over current (steady-state faults) it can result in Protective device tripping (RCCB/MCB) so that SPD will be safe and not get burnt. If you want to avoid this risk, SPD needs to be installed prior to the protective device and an additional protective device like a Backup Fuse or MCB need to be installed for the protection of the SPD.
@rajasidhu268
@rajasidhu268 2 ай бұрын
jino ne baneya hi uni ko samjane me lagge ho hindi me bate to jada asha hota
@AxisElectrical
@AxisElectrical 2 ай бұрын
Hi Raj, Hum Hindi mei samjaane ke liye, ek separate video par kaam kar rahe hai. Umeed hai aap ko woh pasand aayega!
@gssrustenburg
@gssrustenburg Ай бұрын
Thank you, great info.. Also important not to over size spd - e. g. a 1000v spd can not protect equipment with max. 300v input, rather use a 275v so it can protect from 275v spike upwards.
Type of Earth Rods - Technicalities & Applications Explained! ✅
5:57
Axis Electricals
Рет қаралды 3,2 М.
Surge Arresters or Lightning Arresters - What will protect you? ⚡
6:45
The FASTEST way to PASS SNACKS! #shorts #mingweirocks
00:36
mingweirocks
Рет қаралды 13 МЛН
Oh No! My Doll Fell In The Dirt🤧💩
00:17
ToolTastic
Рет қаралды 13 МЛН
Type 1 and type 2 SPD : installation and rules
3:15
CITEL
Рет қаралды 50 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
Why Circuit Breakers DON'T Protect People (electric shocks)
18:23
The Engineering Mindset
Рет қаралды 1,2 МЛН
The Most Confusing Part of the Power Grid
22:07
Practical Engineering
Рет қаралды 1,6 МЛН
What electrical work are you allowed to do in your own home?
10:39