Whole House Surge Protector // Easy DIY Install

  Рет қаралды 4,174

Smith Off-Grid

Smith Off-Grid

3 ай бұрын

Step-by-step install of the Siemens FS140 surge protection device (SPD)
Siemens FS140: amzn.to/48GHTX7
Wire strippers: amzn.to/3843tuw
Non-contact voltage tester: amzn.to/3Q78t4g
** Warning: Electricity is dangerous. Do not attempt the procedures in this video if you're not familiar with electrical safety. Improper handling can lead to serious injury or damage. Always consult with a professional electrician. Your safety is your responsibility! **
This video includes Amazon affiliate links. I earn a small commission from qualifying purchases made through those links, at no extra cost to you.
Sub count: 176

Пікірлер: 10
@asusreviews
@asusreviews 12 сағат бұрын
I'm confused by why you installed it there. Isn't the property under construction currently and will be drywalled in so you can't see the lights or service it later?
@c216mohl
@c216mohl Ай бұрын
Hi there. To answer a question below. Yes, they should be connected as close as possible to the power source(Power Service Disconnect) coming into the panel, when possible. A thing I did was similar to what you did when I installed mine. I used a threaded 1/2" npt pipe thread to 3/4" PVC connection as well, the only difference is I cut the pipe part off so it was just like a nut on the end. I then put the threaded part through the knock out into the FS140 I have so the unit is flush against the bottom of my panel. What you did is not wrong, I just think it looks neater tight against the panel. Thanks for the video! Cheers.
@SmithOffGrid
@SmithOffGrid Ай бұрын
That's an awesome idea! Never thought of doing that. Yeah I bet it looks a lot cleaner that way. The shorter the better, that's great!
@DustinDoesStuff
@DustinDoesStuff 3 ай бұрын
What is the installation method if the breaker box is recessed in the wall with drywall around it. Will the surge protector fit inside the breaker box?
@SmithOffGrid
@SmithOffGrid 3 ай бұрын
I think it would technically fit inside, at least in mine, but it's not really designed for that. Siemens does make a flush mount kit that you can use to mount it recessed in the drywall next to your breaker panel There's also a more compact style of SPD that connects just like a breaker. That could be a good option if you have limited space. You'd just need to make sure you find one that matches the type of breaker your panel uses
@c216mohl
@c216mohl Ай бұрын
@DustinDoesStuff I am sure by now you have gotten your answer...but just incase. If your panel has enough space in it, it is perfectly fine to install it within. The only downside you have is you can not see the lights to be sure it's still working, but the PS140 also has an audible alarm too. Cheers.
@customerservice95
@customerservice95 3 ай бұрын
Did the instructions indicate that the closer to the inlet voltage the better? Being in the bottom corner The Surge still has to pass all the other Breakers before reaching the bottom of the panel
@SmithOffGrid
@SmithOffGrid 3 ай бұрын
I actually wondered the same thing but when reading through the instructions it didn't mention anything about that. It did specify to "use closest breaker to SPD" and "ensure leads are as short and straight as possible". Per their instructions, I'm assuming those two bits are the most important factors? But either way, with my panel I have network equipment on the upper right side and a transfer switch on the left. Plus the wires to the top breakers weren't left with hardly any slack so moving them lower into the panel would have been pretty messy with a lot of splicing. So the bottom seemed like the cleanest option for me. I'd say if you can swing putting the SPD at the top to go for that! It does seem like the most ideal location would be closest to the inlet with having it come directly out one side
@jbw8471
@jbw8471 29 күн бұрын
I didnt use the metal plate. It cost $100 which is ridiculous. Also installed mine inside my panel at the very bottom as thats where the only space for the 2 double 20 amp pole breakers are locbated. I cant see the SPD when i open the panel but the light shines through the spaces where the breaker is. Unfortunately i have the Fs-100 and not the 140. Is it worth switching out???
@SmithOffGrid
@SmithOffGrid 2 күн бұрын
Yeah that $100 plate seems way expensive for what it is! I’d say any SPD is a huge step up from not having one. Comparing the FS100 and the FS140, the difference seems pretty minor. Personally I probably wouldn’t upgrade
Mama vs Son vs Daddy 😭🤣
00:13
DADDYSON SHOW
Рет қаралды 29 МЛН
Как бесплатно замутить iphone 15 pro max
00:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 6 МЛН
Best KFC Homemade For My Son #cooking #shorts
00:58
BANKII
Рет қаралды 61 МЛН
Beautiful gymnastics 😍☺️
00:15
Lexa_Merin
Рет қаралды 15 МЛН
Type 1 and type 2 SPD : installation and rules
3:15
CITEL
Рет қаралды 49 М.
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 149 М.
90% Don't Know About This Fatal Generator Connection
11:17
HAXMAN
Рет қаралды 670 М.
It's Been a Good Run, Drywall.
20:48
LRN2DIY
Рет қаралды 3,1 МЛН
WHY I REMOVE SOLAR
14:10
Solar Goat
Рет қаралды 13 М.
How to Install Surge Protection | Ask This Old House
7:35
This Old House
Рет қаралды 553 М.
Mama vs Son vs Daddy 😭🤣
00:13
DADDYSON SHOW
Рет қаралды 29 МЛН