What happen when A/C continuous running none stop, don’t that cause system to freeze up ?
@acservicetechchannel2 жыл бұрын
Absolutely if there is not enough heat to absorb because the indoor temp has dropped down way too low. However if the temp inside remains the same due to a high heat load then no it shouldnt freeze. If it freezes, that means that you likely have a low indoor airflow problem.
@keovongvilaykeo47992 жыл бұрын
@@acservicetechchannel thanks for advice I think so too airflow issues EWC Zone Control
@workingshlub88612 жыл бұрын
bad thermostat
@gunasekar47642 жыл бұрын
In case if oversize txv is installed then indoor evaporator coil and compressor will get ice formation pls could you advise
@ContinentalAC_Tom Жыл бұрын
@@acservicetechchannel ON 🎯 🎯 🎯 💪🏼 💪🏼 💪🏼
@Matthew-jr1xr10 ай бұрын
Why go to college when you can watch this guy's channel? Haha. Watch the adds, like, comment, subscribe, whatever you can do to help him out. Lord knows he's helping us. 👌
@acservicetechchannel10 ай бұрын
Thank you so much!!!
@PURGE-30006 ай бұрын
I don’t get ads. KZbin red premium
@ed78vette2 жыл бұрын
Dude, you’re OUTSTANDING! I thoroughly enjoy your tutorials. Keep up the great job.
@acservicetechchannel2 жыл бұрын
Glad you enjoyed it!!!
@joecooksey43312 жыл бұрын
Off topic, but you did a video a while back on p-traps. That video is SAVING me $$$. Here's why. 4 ton split 13 years old. It did NOT have a p-trap, but had a decent trickle of water coming out the PVC. I never thought much about it until I watched that video. I installed a Rectoseal trap and dropped the humidity 3-4% (46-47%) inside allowing me to turn the thermostat up 2 degrees. I now have an excellent stream of water coming out the drain! THANKS A MILLION!
@edwinjewell53592 жыл бұрын
Craig You are the Guru of Air Conditioning.
@acservicetechchannel2 жыл бұрын
Thank you so much Edwin!!!
@JohnDoe-gk4kn Жыл бұрын
Thank you. I have a liquid line restriction issue. Now I can speak to my AC guy and tell him quit screwing me over your fired. My guy has been leading me from one thing to another charging me a fortune. Today he said its a leak I need a new Furness but he never perform a pressure test.
@alexandronegrete29978 ай бұрын
You can do that with gauges or pin point the leak you still need certain lincenses to buy refrigerant
@billb.49012 жыл бұрын
Nice video. Your explanations are top notch. I learn so much from your videos. I really appreciate all of your effort to pass along your knowledge.
@acservicetechchannel2 жыл бұрын
I appreciate your encouragement!
@MichaelHernandez-lc2wb2 жыл бұрын
What a perfect, concise, and clear explanation. I cant thank you enough!
@Salty5hoe Жыл бұрын
Learned more from this video than the college I went to in less than 20minutes
@stevenhyn34982 жыл бұрын
Graig - You were born for a big reason. Thank you so much !
@acservicetechchannel2 жыл бұрын
I really appreciate your note!
@natureventurememowi2 жыл бұрын
Sir, you're an amazing teacher. So clear and concise. Thank you!!
@Zolt82 Жыл бұрын
Always so well explained, this guy taught me a lot to improve my skills several years ago. Certainly learned more with him than at school. 😀
@vernroach34132 жыл бұрын
Another good one...Even my brother understood it and he's not in the trade...Thanks again.
@acservicetechchannel2 жыл бұрын
Vern, that is really cool to hear!!!
@gregtoczko4819 Жыл бұрын
Excellent explanation of the problem. I can watch your videos for hours. Downflow system: what may cost liquid (refrigerant line) to sweat? The evaporator coil is freezing only on the lower portion of it ( not always)- according to you it's sign of liquid line restriction. Liquid line is always cold and sweating (most of the time but not always). Suction line is always warmer than liquid line.
@thecoolguy23 Жыл бұрын
Kink in the lines could be another reason for refrigerant restriction!! 👍👍👍 Good video 🤩🤩
@raulo12252 жыл бұрын
Craig you are a master always enjoy your videos
@acservicetechchannel2 жыл бұрын
Thank you so much Raul!
@luke91292 жыл бұрын
Concise, tactful and as always a well thought out explanation Craig. Bravo sir on another video well done!!!
@acservicetechchannel2 жыл бұрын
Thank you ao much Luke!
@gpsfleetmatic2 жыл бұрын
Easy as it should be. Craig, do you have an indepth video on liquid line restriction, causes and how to diagnose it. Why will half of the evaporator core freeze for liquid line restrictions instead of entire coil?
@gpsfleetmatic2 жыл бұрын
@@electricboogie709 before the refigerant would have reached the exit of the evaporator core it must have frozen completely due to very low pressure resulting in lower temperature below freezing point, thus not enough refigerant to pass completely through the system, this is also dependent on the level of restrictions caused by the orifice. I seem to get it clearer now. Thank you Boogie et Craig
@HVACRTECH-832 жыл бұрын
@@gpsfleetmatic not quite, the refrigerant won't ever freeze, only the moisture in the air will freeze onto the coils surface and the distributor tubing. Only part of the evap freezes because the coil is starved of refrigerant which is what is making the pressure low and in turn the temp below freezing on the coils surface. Assuming proper load on the evap, the refrigerant will still boil off into a superheated vapor as it works its way up the coil which will leave the coils surface at that portion above the freezing point of water. If you had a starved coil as well as improper load,the whole thing would be frozen. But this partial freezing will only take place on this design of coil where the refrigerant feeds into one side and exits the opposite,bottom to top, some other designs the whole coil will freeze in both situations but maybe only on the air inlet side so it's always best to let your SH and SC tell you what the culprit is.
@drz400sy92 жыл бұрын
Great Video. My unit started to show water at the evaporator and shut down. Like you mentioned, it was actually my blower motor. Thanks for confirming my issue. Interesting it happened a few days after a HVAC cleaning and addition insulation around to copper tube at the condenser unit.
@chrismammedaty5215 Жыл бұрын
The Vapor line at Work froze. The Filter Drier was outside. It was frozen on the Evaporator size of the Filter Drier only. The problem happened because of a Failed Blower Motor Capacitor. Thank you for your videos.
@prudent85382 жыл бұрын
I think you went through all of the issues! Bahaha amazing!
@dougjones49872 жыл бұрын
Thats quite the mic for an hvac guy. Great info thanks
@robertovaldez29848 ай бұрын
Good information, thank you.
@wildbill5623 ай бұрын
WOW, that was comprehensive. There was alot of water in the pan below my coil and it was not draining - which it should. I sopped up all the water with a sponge and discovered that the lower part of the coil is frozen. The filter was sopping wet, so i got rid of it. It was installed 5 mos. ago, but appeared clean. I had no idea I was supposed to change them every 30-60 days. I checked the outside drain and the ground is all wet, so I don't know if it's clogged or not. I cleaned the coils inside and out before the season, so i know that is not the problem. I'm just going to leave the filter off overnight and see if the increased air flow helps defrost the coil. If not, i will call the HVAC tech and see if the TVX valve needs to be replaced.
@Andreggs-v7k Жыл бұрын
I understand English but i have many friends in the field that only speaks spanish! I wish u had this videos translated much love! ❤❤😊
@ceciliorivera71796 ай бұрын
Saludos te recomiendo darle a la rueda como un eje en la pantalla y buscar subtitulo. De ahí puedes escoger español. Todo lo que el dice lo escribe en la pantalla en español. Espero te haya ayudado.
@Andreggs-v7k6 ай бұрын
@@ceciliorivera7179 que bueno! Muchas gracias cecilio
@bassealhvactech25052 жыл бұрын
this is a great piece. thank you Mr. Craig. i am so loving it
@khalidsr1 Жыл бұрын
Excellent explanation, many thanks😊
@rainman77692 жыл бұрын
Thanks for the easy explanation
@acservicetechchannel2 жыл бұрын
So glad you enjoyed it!
@williamserver43322 жыл бұрын
Great video. I wish I had these videos 20 years ago when I was green. Even now they help
@acservicetechchannel2 жыл бұрын
I wish i did too. The best advice I was given when i couldnt solve a problem was to go out to the street, clear my head and then go back to the service call and keep trying! There were no videos to watch or answers found online or a way to search online while at the customers house!!!
@sunilthaivalappil52292 жыл бұрын
Very nice presentation Thanks
@coldfinger459sub02 жыл бұрын
Saved into my favorites category for HVAC to pass along to others 👍
@acservicetechchannel2 жыл бұрын
Thank you so much for each of your comments! Very encouraging!
@Sido427856 ай бұрын
Thank you so much for this amazing work
@thesilentonevictor2 жыл бұрын
Well put together
@acservicetechchannel2 жыл бұрын
Thanks a lot neilvester!!!
@albertgarcia9662 Жыл бұрын
I enjoy your videos.There is so much to learn. Your boots are much easier to follow . I'm going to college to learn to receive a certificate HVAC. I'll be buying your books hopefully soon. Again thanks
@Mudcat5972 жыл бұрын
Nice presentation and great information. Thank you for sharing!!
@acservicetechchannel2 жыл бұрын
Glad you enjoyed it!
@taiwanluthiers Жыл бұрын
I got a mini split with a capillary tube metering device, and when I charge the system the suction pressure (and only suction) will stop at about 45-50 psi (R22) where the saturation temp is about -5C. It doesn't matter how much refrigerant I add after this, the pressure will not go up even if I end up putting in more refrigerant than what it says on the name plate (basically an overcharge). So I end up just stopping when the AC works reasonably well and not freeze the coil.
@phillipjoy13052 жыл бұрын
You got to love Craig.GREAT VIDEOS 😜
@acservicetechchannel2 жыл бұрын
Thank you so much Phillip! I always enjoy your comments!
@johnt96842 жыл бұрын
Awesome video thank you
@allanfsecusana126 ай бұрын
Thank you so much for sharing
@hvacinstalacije19852 жыл бұрын
Thank you Craig
@holtrussell2 жыл бұрын
Hi Craig, great video, thanks! Would you be willing to take a guess at how many compressors are permanently damaged due to liquid slugging as a result of a failed indoor blower motor / cap. while the system continues to “compress” liquid? I don’t have a clue personally but would be interested in your educated opinion. Thanks!
@funkychunky82702 жыл бұрын
Liquid receiver / suction accumulator brother
@jasonaguilar49292 жыл бұрын
Great video
@acservicetechchannel2 жыл бұрын
Thanks Jason!
@fernandoescobar6922 жыл бұрын
Clear like water, thanks
@rayalvarez77802 жыл бұрын
Thanks again for these videos I’m learning so much from them keep them coming.
@acservicetechchannel2 жыл бұрын
Thanks a lot Ray!
@keovongvilaykeo47992 жыл бұрын
Always appreciate your hard work thanks you again
@acservicetechchannel2 жыл бұрын
Thanks a lot!
@htownnc7132 жыл бұрын
Nice video got your book also Im self taught thanks for the good videos! Still have more to learn.
@acservicetechchannel2 жыл бұрын
Glad you are enjoying them!!!
@Heribertozagada Жыл бұрын
Hi sir I'm bert in Philippines 🇵🇭 I'm learned to much in Refrigeration I'm very interested
@lugongguo81252 жыл бұрын
Thank you so much for explaining so many reasons. Gave a like and keep learning. 👍
@acservicetechchannel2 жыл бұрын
Very cool!
@noellwilson1273 Жыл бұрын
Bravo! I kept hearing “air restriction = freezing” but this is the first time someone has said “air restriction = less phase change to vapor in the evaporator = low evaporator pressure = freezing”. I couldn’t understand why I got 62 psi readings (R-22) when I checked the low side and the chart said that was above freezing (36F from memory). A question: Is there a valid argument that the new HEPA filters restrict the air flow and that a cheaper “horsehair” filter might work better on an old system?
@honestman276 Жыл бұрын
Thanks from Bangladesh.
@bigstepper22352 жыл бұрын
can you do a video on furnace control board dip switches
@danh98462 жыл бұрын
Was wanting to know where to test temp on a vehicle like a bus where to compressor and condenser 20 feet or more apart for proper subcool
@sissonsk Жыл бұрын
I bought a $20 Honeywell digital and programmable thermostat about 9 years ago. Apparently, it stopped turning the A/C blower on and the evaporator froze up. I couldn't get the fan to turn on at all. I just happened to have an exact replacement and, after I de-iced the evaporator, I got the blower to work with the newer thermostat. At least this is what I hope solved the icing problem.
@deohbolik12 жыл бұрын
Thank you for the wisdom.!!!
@yasserd86 Жыл бұрын
Dryer does it matter if it’s outside or inside installed ????
@cck14962 жыл бұрын
Good video. What is A and M on control card? Thanks.
@indiantraveller1942 жыл бұрын
Good
@richardhaen6 ай бұрын
Good video, got a question for u, My ac has two capacitor one for fan one for compressor can I put in one capacitor Com/Fan/H? Same value. Thank u Richard
@ilovenythismuchilovenewyor58012 жыл бұрын
surprised you didn't mention the orifice on some systems .. like some come w txv some come w the fixed orifice and both can get jammed up and cause a restriction... came across a r22 low side line set was frozen all way up to the evap coil. gauges read 25 psig on low side 15p on high and this was w the evap coil frozen... had to let it all defrost so can get a better 3 min reading for low side evap coil temp then another 7 mins to check the rest. but once I disconnected hoses the low side was defrosted and I heard a hissing so the core valve possibly could of been leaking even tho it had a cap on it before and was frozen before I had a actually put hose on low side ... so was suspicious of leak w possibility of low refrigerant but once again needed thr whole unit to defrost to take the pressures while running and also replace core valves w new ones and continue to test for leaks and rule out if it is low refrigerant, check evap coil for dirt build up because did notice the return and supply grills had alot of black dirt on them which indicates the return didn't have filters in it for long time so they ran the unit w out that filter and it could possibly have lead to the evap coil getting caked up w dirt causing bad air flow and last the fixed orifice could be clogged up some how. ... will find out
@johnbutton11955 ай бұрын
On a fun Note: if you ever need side work...You could do Kermit the frog Children's shows! Lol Just saying. Your voice is great!
@acservicetechchannel5 ай бұрын
Not the first time I've heard this!!! Id say two comments a week!!! ha ha! Must be a soothing voice from childhood or something!
@David-yy7lb2 жыл бұрын
Excellent explanation Craig question about hi flow filter, wouldn't that cause more dust to pass through and collect on the evaporator over time and cause flow issues vs a filter that traps everything however is a little more restrictive and cause air flow problems....I guess there's pro's and con's to both filters....do you want more air flow or cleaner air🤷🏿♂️
@HonchoBobbyD Жыл бұрын
Hey y'all, I absolutely appreciate your videos very educational and I can actually follow what you're saying! Thank you so much for doing what you do! I had a question, have you had any issues with Nu-calgons product easyseal? By issue's I mean it causing clogs anywhere in the system? It guarantees it won't cause a clog but I think it may have clogged a txv on a system I did a repair on. Thank you again!
@LMike20042 жыл бұрын
Dehumidifier starting to ice. Are they worth repairing?
@nickcurry85152 жыл бұрын
7:10 "I found another guy to do it cheaper" hahahahaha
@yannkitson1162 жыл бұрын
Is the book in metric units?
@acservicetechchannel2 жыл бұрын
Only standard presently!
@TheWilferch2 жыл бұрын
Any hints on why the outdoor condenser coil ( and also looks like the compressor and tubing inside the condenser housing)....freezes in winter-mode operation "on heat" ???? Bad defrost control?....bad thermostat somewhere?.... faulty reversing valve?.....
@mark.r89007 ай бұрын
Great video. My suction line is frosting up. Indoor temperature is 75F and outdoor ambient is 70F. It's r410a with low suction pressure. The low side saturation temp is 28F. I am getting low superheat but normal subcooling with fixed orifice. Filter is clean and air flow is good. The coil has no frost but frosting just before service valve at outdoor condenser. All amp draws are good. I tried adding some refrigerant but the low side pressure would not rise. I just can't figure this one out. Any help would be greatly appreciated. Thank you.
@ozziewelcome56122 жыл бұрын
Good 👍
@acservicetechchannel2 жыл бұрын
Thanks Ozzie!
@ryanduhaime90865 ай бұрын
Can a 3 ton txv on a 2 ton system cause coil to freeze
@comarshlunan859226 күн бұрын
What about freezing when using the heater?
@btarb2422 жыл бұрын
Curious, is it feasible to omit the 2nd stage cooling wire on a 2 stage heat pump to get more heat capacity? example.. manJ heat=53k and cool is 29k. Using a two stage 4 ton unit would get me most of the heat and be only a about 15% oversized for cooling that's limited to the 70% stage 1.
@farrellnuszjr9216 Жыл бұрын
I have a question should a closed ac Freon unit every need recharged if it never leaks. Or do all units have to be recharged every year or seasons
@danielcovarrubias2331 Жыл бұрын
It’s a closed system, should never leak. No need for recharge unless there is a leak.
@FlockofSmeagles6 ай бұрын
I'm having an issue where the coil is freezing from the line that that's leaving the furnace. It looks like there's a leak coming from the silicone seal. Can a leak like that cause freezing?
@WhenNaturesPeek2 жыл бұрын
Hi sir,it is possible to make AHU that using brine chilled water?
@202upt12 жыл бұрын
Question if one rm is not getting as much air as other rooms what is the problem ??
@nickthegriffin2 жыл бұрын
If you had a r22 system 😆 we got rid of that in the UK years ago
@alifn95302 жыл бұрын
Hight pressure : 103 f° Low pressure : 40f° Sobcooling : 10 f° Superheate : 10f° Return air temp : 71f° Supply air temp : 50f° The évaporateur is always freezing
@douglasnorman8748 Жыл бұрын
I have an interesting problem where my AC doesn't cool enough to drop the temp to say 75. It runs too long and the outside unit shuts down I assume it gets too hot. There is no freezing anywhere. The inside heat exchanger gets cold but I don't think it's getting cold enough. The filter is clean and the indoor fan is good and there seems to be plenty of air moving. The outdoor heat exchanger is not dirty. Tech is coming tomorrow
@JP-hj7fc2 жыл бұрын
How can you test the liquid line restriction or the metering device to determine the problem? And what is the procedure to replace them? De-solder or replace the entire A coil then recharge the system?
@justingibson87882 жыл бұрын
Take bulb off and warm it with your hand or in a cup of warm water. If super heat doesn't adjust then txv is bad.
@justingibson87882 жыл бұрын
And for filter dryers test temp on each side. Should be the same.
@javierguadarrama94052 жыл бұрын
I need to replace a system on a condo, so i can't replace the line set. Can you plese show how to flush the lines from R22 to 410A. Thanks
@anujprakash51369 ай бұрын
Wow 💯
@Welikeitso-e7i Жыл бұрын
I need help my suction line is freezing.my ac has gas I also checked for leaks there is none.my readings are good and i cleaned my ac but still ice only on the suction line.also my blower wheel is making a noise whenever my ac blade is raised up.whenever i lower it the noises stop.anyone has a sollution
@renteria45402 жыл бұрын
If you were a teacher. You would be the best
@acservicetechchannel2 жыл бұрын
I actually am licensed HVACR Teacher, thanks!
@johnleblanc19029 ай бұрын
cool
@fillmorehillmore82392 жыл бұрын
Problem: Indoor blower turns on/new filter. Turn on A/C and runs, once the A/C runs for about 20 min the indoor blower turns off for a few min (AC still running) and starts up for 30 seconds or so. The cycle continues and the AC starts to freeze.
@viob13592 жыл бұрын
I got a new furnace, and now my 16 year old A frame AC unit is freezing. The Cool fan speed is at High. I have switched my filter to the thinnest possible to increase the airflow but it's still freezing over. The furnace guy blames it on the AC A frame unit siting on the furnace and impeding the air flow. He was no help. He installed a temperature gage on the refrigerant line to stop my thermostat but forgot to connect it to a timer, so his solution is to stop my AC from working. I had an AC technician measure the Static air pressure which came out to be 1.07, way outside the manufacturing parameters, it's not even on the chart. The AC technician also said the refrigerant levels are good and we have no leeks. He said there is not enough air intake coming in. The fan sounds too loud when the AC kicks in. Could lowering the fan speed to medium help with the freezing? Do I need to add an intake vent? HELP! 🙂
@Elisummit8452 жыл бұрын
I always tell people there is only 1 reason why an ac freezes. If the temperature of the coil drops below freezing. Why it would drop, there could be a few reasons.
@acservicetechchannel2 жыл бұрын
For sure!
@chriskopec18582 жыл бұрын
❤👍
@eclipse369.2 жыл бұрын
How come you don't do commercial refrigeration as well? You only residential hvac?
@eclipse369.2 жыл бұрын
Too many electronics nowadays like ecm junk.
@MaMa-qh4dy2 жыл бұрын
The cost to replace an ECM module far outweighs the cost/benefit of having ECM motor vs PSC motor.
@alirezaajamzlbad2 жыл бұрын
پشماممم
@keithehrman54904 ай бұрын
Look at that microphone. Dude thinks he's the Joe Rogan of HVAC.
@janielramirez98422 жыл бұрын
Thars not enough information. U left other details out