In this video we are going to discuss about the ;
Why start pump with discharge valve closed?
What happens when centrifugal pump discharge valve is closed?
What happens when you dead head a pump?
The basics of pump startup
what is the purpose of discharge valve?
Why discharge valve closed during starting the centrifugal pump?
Why centrifugal pump is started with discharge valve closed?
Why is the discharge valve kept close before operating the centrifugal pump?
Why discharge valve closed during starting of centrifugal pump?
Pump discharge valve
Why centrifugal pumps are started with the discharge valve close?
Centrifugal Pump Series:
• Centrifugal Pump Series
Industrial Pump Videos:
• Industrial Pump Videos
Process Engineering Series Videos:
• Process Engineering
Industrial Engineering Series:
• Industrial Engineering
Unit Conversion Series:
• Unit Conversion Series
Instrumentation Engineering Series:
• Instrumentation Engine...
Engineering Shorts Series:
• Engineering Shorts
#CoreEngineering #centrifugalpump #industrialengineering #engineering #refinery #powerplant #processengineering
About the Channel :
Core Engineering is a KZbin Channel for those Engineering Students as well as Engineers i.e. Chemical Engineer, Process Engineer, Instrumentation Engineer, Mechanical Engineer, Electrical Engineer, Electronics Engineer, Civil Engineer, etc. who wants to learn about the Engineering concepts from the scratch, wants to know the Technical How of each concept and those engineers who are already working in a Industry.
We will upload the videos related to Industrial concepts i.e. Pump, Centrifugal pump, Reciprocating pump, Compressor, Centrifugal compressor, Heat exchangers, Valves, Reactors, Plant shut down and plant start up, Process safety during plant startup and shutdown and Software used in an Industry, Industrial Engineering, Process Engineering related videos.
That is why! You must Subscribe the Core Engineering KZbin Channel and follow our other social media handles.
Your Suggestions are Always Welcome!
Best!
Core Engineering Team
Contact us : infolearnche@gmail.com

Пікірлер: 35
@Coreengineers
@Coreengineers Жыл бұрын
Watch more technical videos:👇 1. Industrial Engineering Videos: kzbin.info/aero/PLrqNx2OqGF51_BYmmF_z2TrR2x0EkVH3z 2.Industrial Pump Videos: kzbin.info/aero/PLrqNx2OqGF51IVvA2ivV1XdiMRnlWMLsC 3. Centrifugal Pump Videos: kzbin.info/aero/PLrqNx2OqGF513HW1AN7M9sw0kTqnO1ESX 4. Instrumentation Engineering Videos: kzbin.info/aero/PLrqNx2OqGF50F-gYBOccjSb9E-9F8zCi7 5. Piping Engineering Videos: kzbin.info/aero/PLrqNx2OqGF513CRbtuqu77IKBuIak9M3S
@loridave1962
@loridave1962 10 ай бұрын
On all the centrifical pumps I hv used, the best practice was to open the supply fully and nearly close the discharge valve. Almost closed was best. Engage the driver and slowly open the discharge valve. Monitor the sound and pressure gauges. Open the discharge to no more than the rated flow of the pump and certainly not beyond cavitation occurring. This can take some practice and coaching. In school we were taught that a pinched back discharge is doing less work than an open discharge and that is why an electric motor driver draws less current when the discharge is closed versus open. And During electrical preventive testing I hv seen that the current is less when the discharge is pinched back. So , yes, a soft start is easier on the driver. Additionally, if the suction line is only partially full of liquid at start up, the soft start is necessary to nurse the vapor thru the pump. A liquid centrifical pump has a hard time moving vapor. A wide open discharge would merely sling out all the liquid and the pump would have no prime and not be able to develop suction. And with no suction the vapor just sits in the pump and no liquid will flow. Do not run a pump with the discharge closed, or pinched back hard, more than momentarily. Read the manufacturers instructions . Perfect your skills . Be careful about getting incorrect advice from co workers. Understand the physics of what is writen or are told before accepting it as fact.
@hadjkouideryounes5634
@hadjkouideryounes5634 8 ай бұрын
In the first time you say that the best is to start the pump with the discharge closed and another time you say don't start the pump with the discharge closed, I don't understand
@dicko-200
@dicko-200 6 ай бұрын
more than a moment @@hadjkouideryounes5634
@Cosas47
@Cosas47 29 күн бұрын
Can it help if you use a soft starter for start the pump? There are some applications that does not allow to continue operate that valve. For example, pumps that work automatically according to tanks level with no supervision
@loridave1730
@loridave1730 8 ай бұрын
Hadj, I think you misread. Please check. Again, it is important to start the pump with the discharge nearly closed (it is ok to start with the discharge completely closed with some pumps). Start the pump driver and promptly open the discharge valve a small amount. Monitor the sounds you are hearing and the pressure gauges (and vacuum gauge if you have one). Let the sounds and gauges stabilize. Open the discharge valve just a little more and repeat and repeat. Do not rush this process. During this start-up process the discharge pipe has a lot of vapor in it and just a little liquid. If the operator opens the discharge valve too fast, the pump will sling all of its liquid into the vapor space in the discharge pipe. When this happens the pump loses its prime and even though the pump driver and pump are rotating, the pump, with no liquid in it, can not suck more liquid into its intake. The pump impeller and volute require a little liquid to seal the internal gaps between the two. Certainly if there is a lot of relative head pressure on the supply liquid at the pump intake, the pump won't lose prime but this is not common. Hadj, I did state not to run the driver with the pump discharge closed, but it is ok to to start with the discharge closed or almost closed, just do not run the pump with it closed, but at initial momentary start-up its ok to. As I said above, it is necessary to. But, do not leave the discharge closed for more than a very brief moment. Running a pump with no liquid flowing thru it (running it dry) will cause heat to build up quickly. You may not feel the pump body getting hot (but you might), however the drive shaft, its seals, and bearings will quickly get hot if there is no liquid to cool keep everything cool. And the liquid also lubricates the shaft seal. This heat will burn (coke the residual liquid) the shaft seals which then results in a leak which then results in an inoperative pump and no productivity which results in repair costs and.may result in a new operator. Running a pump dry, because liquid supply ran out or because a supply valve was shut, dictates that the pump driver be shut off immediately. Shutting supply or running out of liquid are what I have seen cause the most --if not all--pump leaks. In these cases I have later always found the pump shaft seal(s) with coked liquid and deformed polymers. . Inattentiveness or lackadaisical operator error every time. A good pump operator makes for a happy boss.
@pratikmetangale
@pratikmetangale 23 күн бұрын
There is NRV present in discharge line already, so is it make point that valve is close or open... Coz nrv will do its work.
@thomassim5600
@thomassim5600 7 ай бұрын
Thanks for the knowledge 😊
@punjab4816
@punjab4816 Жыл бұрын
thank you so much sir 🙏
@prasadshetty8823
@prasadshetty8823 10 ай бұрын
Thank you for the knowledge sharing....mean while I have a one doubt , is there any effect on impeller or mechanical seal if we close the discharge valve?
@affanbhaijaan65
@affanbhaijaan65 Жыл бұрын
Good🎉
@irfanbashir9288
@irfanbashir9288 9 ай бұрын
you explained really well. how reverse flow can damage the pump which specific part can be damaged
@sagardipjana2059
@sagardipjana2059 5 ай бұрын
But sir, we are using NRV Then how is it possible??
@user-dv7bt6pc6m
@user-dv7bt6pc6m 4 ай бұрын
How liquid can back flow from discharge to the suction at the same time high current value of motor ,, i mean the motor at this time working at highest capacity?
@baijuupadhyay6891
@baijuupadhyay6891 Жыл бұрын
Sir plz make video on self priming pump, humble request 🙏
@Kasiramaniyer
@Kasiramaniyer 5 ай бұрын
Not to suggested close the discharge line.. Depend on valve we used at discharge end..
@maqboolvahora9925
@maqboolvahora9925 5 ай бұрын
After starting pump, Recycle flow control valve piping hammering and High vibration to maintain minimum flow. Kindly explain and give advice , solution
@Coreengineers
@Coreengineers 5 ай бұрын
Check the pump curve for that pump and also check the sizing of line..... hammering have many reasons improper sizing, high velocity, no support could be few...
@user-pn6sv5oc9z
@user-pn6sv5oc9z 11 ай бұрын
how many time that's we required to close the valve?
@Coreengineers
@Coreengineers 11 ай бұрын
When?
@badawg4876
@badawg4876 2 ай бұрын
One point you made during the video is misleading. You stated that the pump is at minimum resistance when the discharge valve is closed. This is incorrect. The pump has minimum resistance when the discharge valve is OPEN. When you close the discharge valve, the pump will have MAXIMUM resistance. Essentially you are deadheading the pump (max resistance, no flow). In other words, closing the valve provide resistance. YOU ARE RESTRICTING THE FLOW.
@shaneabbas3985
@shaneabbas3985 Жыл бұрын
Make it in hindi...That would be great and be clear on the point..
@Coreengineers
@Coreengineers Жыл бұрын
Please visit @Learn EEE for Hindi video
@youssef7253
@youssef7253 10 ай бұрын
Noo lot of us dont understand hindi Thank you for uploading english vids
@zeeshanmalik5426
@zeeshanmalik5426 8 ай бұрын
Suppose i close the discharge valve for longer period of time and meanwhile the pump is running what harm it can cause to the pump ?????
@rashadalakbarov9394
@rashadalakbarov9394 8 ай бұрын
The fluid will start to heat up , and that could lead to damage to seals , internals etc
@ravindrajoshi822
@ravindrajoshi822 6 ай бұрын
How to drain discharge line???
@Coreengineers
@Coreengineers 6 ай бұрын
There are multiple ways to do that....some times in discharge line that provision is provided or pump manufacturers also give that insights.
@ravindrajoshi822
@ravindrajoshi822 6 ай бұрын
What I really asked where to drain provision provided before or after NRV??
@renjithsuvarnan7119
@renjithsuvarnan7119 8 күн бұрын
How there will be back flow when pump discharge has NRV😅
@Coreengineers
@Coreengineers 7 күн бұрын
Due to leakage or may be due to back pressure
@keshavgokhaledivine
@keshavgokhaledivine 10 ай бұрын
Why are you asking the questions? Who's going to reply and how?
@Coreengineers
@Coreengineers 10 ай бұрын
So what's you want the spoon feeding? Those who'll be intrested to watch and learn.....they should give the answer.
@subratanaskar-hm8tm
@subratanaskar-hm8tm 3 ай бұрын
If discharge valve is open then suddenly flow will reach high value and we know power consumption directly proportional to the flow rate .and due to this if pump hydraulic power exceeds the motor power then pump will be tripped To avoid tripping issue we need to throttle the discharge valve before starting the pump.
@bradshsi
@bradshsi Жыл бұрын
The video is a gross oversimplification. High NS pumps will have a higher power consumption at shut valve. Other than that the video contains numerous errors such as stating: 5:18 "no discharge head or minimum discharge head" Incorrect. The pump produces its maximum head at shut valve. 6:20 "closing the discharge valve avoids additional load on the pump" Incorrect. Radial and axial loads on the pump are highest at shut valve 6:40 The scenario of reverse flow can't happen since you have a non return valve.
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 114 МЛН
Why You SHOULD NOT Study Mechanical Engineering
11:48
Engineering Gone Wild
Рет қаралды 155 М.
Centrifugal Pumps
8:26
Laney Machine Tech
Рет қаралды 1,1 МЛН
The BEST Engineering Degrees RANKED (2024)
13:58
Engineer-Millionaire™
Рет қаралды 3,2 М.
Pump Chart Basics Explained - Pump curve HVACR
13:05
The Engineering Mindset
Рет қаралды 1,8 МЛН
Centrifugal Pump Repair and Maintenance Procedure- Part 2
10:02
Technical Engineering School
Рет қаралды 122 М.
Do Pumps Create Pressure or Flow?
10:38
Practical Engineering
Рет қаралды 1,4 МЛН
why we open discharge valve of the reciprocating pump before starting the pump
6:46
Technical Questions Hub Question and Answer
Рет қаралды 3,5 М.
Pump Piping Stress Analysis - Centrifugal Pump Piping Design
8:27
PipingStress
Рет қаралды 11 М.
Installation of Centrifugal Pumps
7:45
SIHIPumpsColombia
Рет қаралды 202 М.