Why Does My Air Conditioner Breaker Keep Tripping?

  Рет қаралды 18,616

Taddy Digest

Taddy Digest

Күн бұрын

If you're wondering why your air conditioner breaker keeps tripping, watch this video for an explanation and tips on what to do next. Learn more about HVAC training videos and troubleshooting AC breakers in this informative video.
Compressor Overload Protection: Mastering HVAC Basics Video
• HVAC Compressor Overlo...
How to keep a compressor from failing? Video
• How to keep air condit...
How to replace compressor, fan and contactor? Video
• Fix AC in 3 steps: Com...
How to know if the Compressor is Bad? Video
• How to know if the Com...
How to use superheat and subcool to charge an air conditioner? Video
• How to use superheat a...
How To Charge an Air Conditioning System? Video
• How To Charge an Air C...
HVAC Tools I use
Yellow Jacket 42004 Series 41 Manifold with 3-1/8" Gauge
amzn.to/3yaYAd3
Fieldpiece SC440 True RMS Clamp Meter with Temperature, Inrush Current, Capacitance and Backlight
amzn.to/3SNaC4e
Join this channel to get access to perks:
/ @taddydigest
Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
• HVAC Tips for Technicians
Taddy Digest Website
taddydigest.com/
Click this link to get your website consultation.
moderncontract...
Modern Web Studios has Built, hosted and maintained my Website.
modernwebstudi...
Fill out the contact form at modern web studios

Пікірлер: 79
@Quattro_Camacho
@Quattro_Camacho 7 ай бұрын
I learn more from this guy, Than my trade school lol
@tech5298
@tech5298 7 ай бұрын
Before you pulled the old breaker out, I noticed that they weren’t resting in similar positions. One toggle was slightly lower than the other. I’m not sure what an electrician would say, but whenever I see something like that, I’m suspicious of the breaker. (now after watching it that’s amazing that you caught that!)
@mxslick50
@mxslick50 6 ай бұрын
As an electrician, I would say it shows there is a problem. Good catch.
@thecreaturesdancedlikeus3922
@thecreaturesdancedlikeus3922 7 ай бұрын
Something new I learned. You never know who was there before you. Good job bud!
@anthonyelectric6045
@anthonyelectric6045 7 ай бұрын
Good job finding that situation. It’s called “listed and labeled” in the electrical code section. Good one Tad
@anthonyelectric6045
@anthonyelectric6045 7 ай бұрын
Hey Tad, can you give some information on that York heat/ac condenser? I’m looking into replacing current ac with a 20 seer heat pump. Also like the soft start feature etc
@ericmaldonado6374
@ericmaldonado6374 3 ай бұрын
Great video as always 👍 learning from the Master , keep up the good work , greetings from Miami 👊
@TaddyDigest
@TaddyDigest 3 ай бұрын
Awesome, thank you!
@walterpreza4969
@walterpreza4969 5 ай бұрын
Thanks , I learned a lot of new things...I live in the state of Virginia.
@TaddyDigest
@TaddyDigest 5 ай бұрын
Great to hear!
@promiseogochukwu-z5j
@promiseogochukwu-z5j 3 ай бұрын
God bless you for posting this video
@nigelhosein7822
@nigelhosein7822 7 ай бұрын
Hey taddy man I just enjoy your videos. Came across a triping breaker on a 3ton unit when I checked the compressor it grounded the winding was toasted
@poipoi4711
@poipoi4711 7 ай бұрын
Hey I just started learning hvac systems I roughly understand how they operate but I’d love your version of a beginner’s guide to the field maybe a vid of you repairing something while also explaining a bit of why and how you’re doing it (thanks for the vids I really enjoy them)
@agustinpadilla4034
@agustinpadilla4034 Ай бұрын
Good video I m from Enid Oklahoma
@thomasdaddy7156
@thomasdaddy7156 7 ай бұрын
Absolutely great video you really do a great job showing things to look out for
@Threee_Eyez
@Threee_Eyez 7 ай бұрын
Awesome video, have yet to run into this one but I'm glad I have now seen this video and it will help me in the future when it does happen, thank you sir.
@AkweteyVivian
@AkweteyVivian 6 ай бұрын
Hi am William from Ghana Bro l have learn a lot of jobs for your videos Thank you
@TaddyDigest
@TaddyDigest 6 ай бұрын
You are very welcome
@GCCCompany-y3b
@GCCCompany-y3b 7 ай бұрын
Thank you for that for that information didn't know a break I could cause that much problem if it's not the right breaker for the box.
@potatolew4495
@potatolew4495 7 ай бұрын
I am a marine HVACR tech. I had basically the same issue on three occasions on three different yachts. The complaint was that the compressor breakers were tripping. The first call, I found the wires from the compressor unit to the disconnect didn't have the insulation stripped, and one of the three terminal screws were never tightened. (It was a three phase unit.) The other two, the breakers in the main distribution panel, were not only from a different manufacturer. The terminals were actually bent and filed down to fit the buss bar configuration. These loosened up so much over time that I ended up replacing the entire panel as the buss lugs were secerly pitted due to arcing. The modified breakers were an easy find because as soon as the system was activated, I could hear arcing in the panel. It was as if someone was spot welding. That was almost 25 years ago that I had my first experience with such an issue. After that, I check the condition, amperage draw and tempature of every breaker related to the unit being serviced. I also check that they are the proper brand and style.
@gilbertopatino2616
@gilbertopatino2616 7 ай бұрын
Thank you so much for a fantastic explanation 🙏🏻👍and great video 👏
@Eddy63
@Eddy63 7 ай бұрын
Good catch Tad ... Thx
@priceless409
@priceless409 7 ай бұрын
Great catch
@yellow61ful
@yellow61ful 2 ай бұрын
A good commonsense troubleshoot.
@matthosseini4194
@matthosseini4194 7 ай бұрын
Good catch 👏👏like always 👍👍 thanks for informing
@peterman8058
@peterman8058 7 ай бұрын
Good catch brother, great job!
@donb3026
@donb3026 6 ай бұрын
Great stuff 🎉🎉
@TomLawson05
@TomLawson05 7 ай бұрын
Great job and video thanks for the good info always enjoy your videos
@HectorVela-d8c
@HectorVela-d8c 7 ай бұрын
excellent video
@OcRefrig
@OcRefrig 6 ай бұрын
Great video Tad. !
@GreyRockOne
@GreyRockOne 7 ай бұрын
Wow, who'd a thunk it! Attention to detail is key! You never disappoint my friend! And for anyone reading these comments, cancel all your "other" HVAC channel subscriptions, Tad is the only channel you need. Thanks Tad! John in VA #giveaway
@DS-fb9te
@DS-fb9te 7 ай бұрын
You are the Man. Love your vids.
@YTsux24-7
@YTsux24-7 7 ай бұрын
Did you check if the wires were tight at the breaker in the main panel? That'll make the breaker trip.
@TaddyDigest
@TaddyDigest 7 ай бұрын
Yes sir that's a good point
@ManuelLopez-t8f
@ManuelLopez-t8f 7 ай бұрын
Everything was helpful thanks Washington DC NW
@TaddyDigest
@TaddyDigest 7 ай бұрын
Glad it was helpful!
@carlosbarcelo2010
@carlosbarcelo2010 6 ай бұрын
❤TX Excellent work ❤
@keovongvilaykeo4799
@keovongvilaykeo4799 7 ай бұрын
Always great thanks 🙏 you 😊
@karellfernandez73
@karellfernandez73 7 ай бұрын
Good video. Thanks
@danpresson
@danpresson 7 ай бұрын
Great job tad
@olurotimiadepitan5087
@olurotimiadepitan5087 7 ай бұрын
Thanks Tad. You are the cool guy.
@nicholdas
@nicholdas 7 ай бұрын
Great video!
@deanmartin1966
@deanmartin1966 7 ай бұрын
Good video
@jeffreywhitlatch1409
@jeffreywhitlatch1409 6 ай бұрын
Excellent video, Homeline will fit ITE but ITE won't fit Homeline.
@terrycapehart6303
@terrycapehart6303 7 ай бұрын
Thank you sir, sq.d and seaman, have a blessed day America
@mrd4292
@mrd4292 7 ай бұрын
Cool job.
@boeing757pilot
@boeing757pilot 6 ай бұрын
Solid video. Great! Thanks.
@pmichaelhayes
@pmichaelhayes 6 ай бұрын
Fused disconnects are great!
@taiptran1
@taiptran1 Ай бұрын
thank you
@TaddyDigest
@TaddyDigest Ай бұрын
You're welcome
@mahatalentndlovu2784
@mahatalentndlovu2784 7 ай бұрын
I wanna work with you Tad😊
@butchbutch7521
@butchbutch7521 Ай бұрын
Awesome
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity 7 ай бұрын
Get yourself a Wiha insulated screwdriver set on Amz. You’ll love them. Much safer.
@ablejohnson
@ablejohnson 6 ай бұрын
Solid
@SombraLocs
@SombraLocs Ай бұрын
Was that an insulated screw driver? Wasn't the line side always hot unless you turned off the breaker at the panel.
@john7017
@john7017 3 ай бұрын
Also, I always place a dab of no ox on the breaker contacts on outdoor enclosures.
@TaddyDigest
@TaddyDigest 3 ай бұрын
good idea
@AaABbB-sg5cr
@AaABbB-sg5cr 7 ай бұрын
"i got a friend of a brother that does this for 10$" - said the homeowner. and this is what happening when ur dirt cheap.
@jcaleca60
@jcaleca60 7 ай бұрын
When the breaker doesn't fit correctly you don't have a good connection which produces a high resistance a high resistance causes a high Amps draw which produces heat the breaker will trip because of the high a draw😊 Good job sir I'm retired now had back surgery but I ran into jobs like this use the right breaker for the panel that it's made for but sometimes they don't feel like waiting 2 hours in a supply house I get it but do the job right it won't come back to bite you in the ass.
@champagnetop9979
@champagnetop9979 7 ай бұрын
Can you link the meter you’re using here
@CreativeMaintenanceSolutions
@CreativeMaintenanceSolutions 7 ай бұрын
That's the first time I've ever seen a breaker on a disconnect!
@The4thshodow
@The4thshodow 7 ай бұрын
are the gloves insulated?
@BLUAIRHVAC
@BLUAIRHVAC 7 ай бұрын
Should be using an insulated screw driver, you slip and touch that box or your hand slips and touches that screw driver shaft then it's game over! Hope someone watching this doesn't try this and get hurt! ALWAYS TURN OFF THE BREAKER THAT FEEDS THE BOX BEFORE YOU STICK A METAL OBJECT IN IT! SAFETY FIRST! JEEEZ!
@soydelrancho
@soydelrancho 7 ай бұрын
Actually. That wire could be # 8 and breaker should be 60A. According to the US NEC
@calmdownplzz1662
@calmdownplzz1662 7 ай бұрын
Installed a new compressor a week ago in a condenser. A few days later I was called back for no cool. A fuse had blown in the disconnect (new fuses). Unit tag calls for a 40 amp minimum fusible disconnect. Here a 30 amp disconect was installed originally with the unit. Going back tomorrow with a 40 amp disconnect. Any other possibilities anyone can think of or likely just the undersized disconnect/fuses?
@tech5298
@tech5298 7 ай бұрын
Use a 60 amp disconnect w 40 amp fuses ( just in case newbies are gleaning the comments)
@calmdownplzz1662
@calmdownplzz1662 7 ай бұрын
@tech5298 hahaha hey thank you, ended up doing this. Funny thing since that last call back and I replaced the burnt (new) fuse w another 30. The unit has ran w no issues w that second new 30. Still replaced the disconnect however. Possibly a bad new fuse out the box🤷‍♂️
@zahedaminullah6934
@zahedaminullah6934 7 ай бұрын
Good catch Tad, in shorter sentences, don't follow what the last dude put in.
@mss3834
@mss3834 7 ай бұрын
There are many reasons they can trip. Bad breakers are rare. But with yorks problems are common. Installed 2 new systems. Both within 6 months had leaks in microchannel coils and both totally burned up the compressor plug and connections. Yorks can’t handle the heat in az I assume and they are among the most expensive brands just overpriced trouble. I had one recently 4 yrs old low pressure 275 high 230. Compressor sounded like drums. I was unable to fix it without compressor and I installed new (different brand) problems gone. And before you say “mismatched system” it has first company air handler in condo. I think York has problems particularly in 115 degree heat. I will never install one ever again.
@tech5298
@tech5298 7 ай бұрын
Ive seen two York gas-pacs on roofs, both caught on fire in the controls area.
@samsquires2877
@samsquires2877 7 ай бұрын
You voided the UL listing for that disconnect by using a Siemens breaker. That breaker has to be a Square D breaker because it’s installed in a Square D disconnect. Otherwise the UL listing is voided. This is coming from a licensed electrician.
@heatncool
@heatncool 7 ай бұрын
Cuz the dog pissed on it 😜
@rightlydivided
@rightlydivided 6 ай бұрын
unsubscribed due to "private content" video's. Dude just do videos and trust God to provide
@scottepperson7709
@scottepperson7709 7 ай бұрын
That's why I don't use square D.
@mxslick50
@mxslick50 6 ай бұрын
@@scottepperson7709 Why? The Siemans was the wrong breaker and the one that failed. SqD is a solid breaker when used in the correct panel. And the Homeline internals (minus the trip indicator) are EXACTLY the same as the QO style. Siemans breakers work well when used in the correct panel.
@scottepperson7709
@scottepperson7709 6 ай бұрын
@@mxslick50 I believe SquareD is a good platform. I also believe they think their better than everyone else. You can put SquareD in other manufacturers but not the other way around. If that had been Eaton or GE there wouldn't have been a problem.
@mxslick50
@mxslick50 6 ай бұрын
@@scottepperson7709 Not a good argument sir. GE is the absolute WORST breaker out there, thermal trip only, tiny bus connections and super high failure rates right out of the box. One commercial job I was on with GE breakers, over 15% of the GFCI breakers were defective, and over 7% of the standard breakers were defective. This was out of a few hundred total breakers on that job site. And yes, history has proven that SqD IS better than everyone else. Eaton is not a bad brand however. (Eaton is still not approved by them or SqD for use in a SqD panel.) And no, you cannot put SqD breakers in other panels it is a violation of the *breaker's* listing. Regardless of what other manufacturers claim, SqD (Schneider) has never approved or listed their breakers for use in other manufacturer's panels. (They do make bus assemblies for use in OEM applications though, like air handlers, etc.) Over my 45 years in the trade, I have seen far too many (as in hundreds of) breakers and panels burn due to use of the wrong breaker for the panel. Even a few where "approved" substitute types were used. I can count on one hand the number of SqD panels with SqD breakers that have failed. (And most of those were due to environmental factors not an inherent shortcoming of, or defect in, the equipment.) That said, Eaton, Murray, C-H, Siemans and others have indeed tested and approved other brands for use in some of their panels, but that had to get testing agency (UL, ETL, etc.) tests done to approve them. And they generally survive just fine.
@JacksLore
@JacksLore Ай бұрын
Brilliant lesson
@RayTrammell-z2e
@RayTrammell-z2e 2 ай бұрын
can you do a reversing valve troubleshooting video?!? TIA
Reversing Valve: How It Works, Diagnosis & Replacement
34:31
Taddy Digest
Рет қаралды 6 М.
Air Conditioner Keeps Tripping Breaker... Stop Resetting it!
25:37
HVACR Survival
Рет қаралды 38 М.
"Идеальное" преступление
0:39
Кик Брейнс
Рет қаралды 1,4 МЛН
Jaidarman TOP / Жоғары лига-2023 / Жекпе-жек 1-ТУР / 1-топ
1:30:54
She wanted to set me up #shorts by Tsuriki Show
0:56
Tsuriki Show
Рет қаралды 8 МЛН
How Do Relays and Transformers Work in HVAC?
22:38
Taddy Digest
Рет қаралды 211 М.
AC Keeps Tripping Breaker and The 10 Most Common Reasons Why
12:34
Word of Advice TV
Рет қаралды 558 М.
Gas Valve Troubleshooting Secrets Beginner HVAC Technicians Need
16:58
MASTER the Thermostatic Expansion Valve in the HVAC Industry!
25:03
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 1 МЛН
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 255 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,4 МЛН
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 857 М.
"Идеальное" преступление
0:39
Кик Брейнс
Рет қаралды 1,4 МЛН