Thank you for the video, for years I always wondered why the bookstore at the mall always had a hissing thermostat, now I know.
@uclabh553010 жыл бұрын
I always enjoy watching your videos . I have learned quite a bit from your training videos because I am also work in a building which has many pneumatic thermostats control. Thanks for keep doing what you are doing everyday.
@kwacz Жыл бұрын
I used to have pneumatics in a building I worked at. They can be finicky, but once you've worked on them for a while it gets easier to calibrate these systems. I kinda like them because their different. Tstats, valves, dampers, switches, low limits, etc... were all pneumatic. leaks in the system can cause them to not operate properly as well. The system has since been upgraded to digital controls which can now be controlled from a computer offsite.
@whatevernamegoeshere36446 жыл бұрын
This was a great tutorial. I saw this issue somewhere and checked because this was a mystery to me. I didn't even know these could be pneumatic
@rgonz63ful2 жыл бұрын
Thank you for this video. It was really helpful to me.
@robertarnold66728 жыл бұрын
Also what can cause a hissing t-stat is that the O-rings ( S & R) are bad & need to be replaced. When the O rings are bad the T-stat cannot make a positive connection. Had to replace several of them today in my building. I just cut them off the clear tubing & install them on the original air lines if they are in good condition. Also a twisted or warped metal t-stat mounting plate can prevent a solid connection.
@luisolivera96087 жыл бұрын
Thank you, I went to an orientation for a job and they showed me this system for a water chiller. I got to calibrate one. It takes some time to get it right. It had some hissing so I hope I get to fix them if hired. Have 3/4 of refrigeration classes done but got out of school 4 years ago and need to get back ASAP.
@marks993510 жыл бұрын
Thanks man, the change out and the other possible reasons - leaking diaphragm, etc. Thanks!
@kansasthunderman110 жыл бұрын
Have you ever heard of a company called National Regulator Co. of Chicago? National was the original inventor (some time in the 1850s) of the pneumatic thermostat used for steam radiators.
@CoryCDS9 жыл бұрын
Pneumatics are such a pain in the ass
@robertarnold66728 жыл бұрын
They were for me when I was inexperienced but now they are not too bad.
@michaellong837910 жыл бұрын
Excellent!
@heartdragons8 жыл бұрын
Very helpful. lots of information and good explanation of 3 reasons as to why there would be a hissing sound. If only I was allowed to fix the issue, that would be great. lol (its at my school and we have to wait for a maintenance order to be accepted)
@juanc108 жыл бұрын
Awesome video. Thanks.
@trezex89795 жыл бұрын
Is anyone here from The Proper People exploring the Abandoned Mental Hospital with power with the hissing thermostats?
@quadrplax4 жыл бұрын
I am, but I was also wondering this because I found one of these hissing myself.
@trezex89794 жыл бұрын
quadrplax oh right
@michaelLeeMagnolia Жыл бұрын
Yes here from the same thing
@vatomicnxbula1993 Жыл бұрын
YESSSS
@pekkatoikkanen399610 ай бұрын
YAsss
@sidtrex17 жыл бұрын
Thank you I'love your v d o. Good education sir
@quadrplax4 жыл бұрын
Why are pnuematic thermostats even used? It seems like just using wires would be simpler.
@djraepa3 жыл бұрын
lol
@whiteguy41203 жыл бұрын
That’s where the HVAC world is leaning towards. It’s DDC direct digital control. Don’t do HVAC, be a controls guy they make way more money and you don’t have to break your back. You need more brains than bronze!
@juandominguez16347 жыл бұрын
awesome video and well explained. Keep up the great work. Are there any other problems that could cause the T stat to leak like that?
@ChrisRubeo6 жыл бұрын
I'm remodeling in an office and have to move the thermostat. There are tiny copper pipes in the ceiling above the thermostat with rubber tubes going down into the wall to the thermostat. Any ideas on the best rubber tubbing to use?
@fathmasameer75238 жыл бұрын
Sir can u explain some thing about elctronic expansion valve plz
@sharonprystup13759 жыл бұрын
thanks for all t he tips
@spencerfenton3 жыл бұрын
Hey Ken where can I buy that gauge
@KenTraining3 жыл бұрын
I got mine from Allied Refrigeration but you can get at any AC supply house/store
@MrGabriel19734 жыл бұрын
How about if it need adjust pressure How you do that?
@KenTraining4 жыл бұрын
check out my channel, I think I have videos on this