The thermostat could be filled with oil or like you said, damper diaphragm could have a small pin hole or the heater or valve is sticking just have to pinn point the issue. Love the video thanks for your hard work
@Mixce33-p9t2 жыл бұрын
Great Video! I have begun working in pneumatic controls, and have been learning as I go. This video helped to bring the concepts together. Thanks!
@mattc33854 жыл бұрын
Thanks, Ken! I am an apprentice and no one really goes over pneumatics. I am really uncomfortable on pneumatics calls. You really cleared some stuff up for me.
@dorwinglopez712110 жыл бұрын
this is awesome and very informative,thank you for taking the time to make his video.
@shadcoats284 жыл бұрын
GREAT STUFF HERE KEN
@tcwphalanx39427 жыл бұрын
Most excellent video. Very comprehensive. Thank you.
@sal151410 жыл бұрын
Good video with lots of useful info - well done. You mentioned doing a video on velocity controllers, which would be a nice complement to this one, hopefully it's still on your to-do list :)
@deltafour12129 жыл бұрын
Find the spring midrange of your valve Example: spring range is 3 to 6 psi the midrange is 4.5 psi. Measure room temp and set the dial on your T'stat to Room Temp, Insert your pressure gauge calibrate the pressure to 4.5psi. Done
@ThePharris1610 жыл бұрын
Good video. How would you calibrate the t-stat if the damper operator spring range doesn't match up with the controller start point and range
@KenTraining10 жыл бұрын
Calibrate to the mid point of the controller.
@cali_gold310210 жыл бұрын
Dont know if you take suggestions, but if you do, it would be great see a video on adjusting a KMC CSC-3011-10 reset volume controller. Thanks! Awesome vids!
@BenAmoz9 жыл бұрын
Where is your video on calibrating the velocity controller??
@KenTraining5 жыл бұрын
I guess I did not make one yet, Sorry.
@kansasthunderman110 жыл бұрын
Have you ever heard of a company called National Regulator Co. of Chicago? National was the original inventor (some time in the 1850s) of the pneumatic thermostat used for steam radiators.
@KenTraining10 жыл бұрын
No, I have never heard of that company.
@mrvelleful2 жыл бұрын
Does such a pneumatic system work even if the input (from the compressor regulator) is not stable? Is it important to keep the pressure constant and at exactly 20psi?
@KenTraining2 жыл бұрын
you have 2 regulators. One for the compressor maintaining tank pressure and a second regulator maintaining the 20 PSI for the Pneumatic Air.
@mrvelleful2 жыл бұрын
@@KenTraining Thanks :) and then, how important is it to keep it at those 20 psi. What if it drifts of to 25psi? Will that affect the output of the thermostat?
@KenTraining2 жыл бұрын
Yes, the Thermostat will have a MAX psi rating and you don't want to exceed that.
@nickmiller45449 жыл бұрын
Hi Ken, how about siemens powermite 599-01088 Pneumatic Valve Actuator for heating zone valve, what spring range to calibrate the thermostat? i didt see it the range on the valve it self
@Dan788627 жыл бұрын
Hi Ken, My question is if its a RA system, Should the velocity Control for heat mode be on Normally Closed or Normally Open setting? I know Cooling should be set on Normally open. This would be for a dual duct system with Heat fans supplying hot air to duct.
@KenTraining7 жыл бұрын
I believe it is normally closed. let us know how it works?
@Dan788627 жыл бұрын
Correct. It is normally closed. Thanks for sharing the videos. Doing an awesome job.
@hernan38204 жыл бұрын
hi Kent i work with you at arden realty can you come over to el monte GOOD VIDEO
@KenTraining4 жыл бұрын
I remenber you bought a Mustang!
@hernan38204 жыл бұрын
@@KenTraining i got a camaro now lol
@fredrosas25757 жыл бұрын
thank you for your time.
@Losangeles19808 жыл бұрын
excellent video, thank you sir!
@derrickgarcia3035 жыл бұрын
On DA stat on a N/O valve. The valve would close as pressure increases correct?
@KenTraining5 жыл бұрын
yes with a N.O. valve
@nightone97202 жыл бұрын
Thank you
@davidringer5006 жыл бұрын
Good info...
@edgarvalencia38275 жыл бұрын
Hey ken shouldn’t your heating duct be N.C on a D.A thermostat, so that would mean that at 0-8 psi the damper should be closed still
@KenTraining5 жыл бұрын
yes for a heating duct.
@nickmiller45448 жыл бұрын
please make a video for Siemens Rc 195 receiver controller calibration, thanks.
@blackezi37 жыл бұрын
Hello Ken What is your job description? I love HVAC, but I don't want to be a regular HVAC tech Are you a Stationary Engineer? or a Controls Engineer for HVAC?
@luisatay36189 жыл бұрын
Would you teach at occ
@KenTraining9 жыл бұрын
+Luis Atay yes, I would.
@bass5556667778 жыл бұрын
I am confused about the hot water valve as it works from 5- 10 psi and also you talk about thermostat from 0-13 psi and then the table is just from 5.5 to 13 it is not clear
@Astrojamus Жыл бұрын
building engineer here... lightbulbs are starting to flicker........