That Heatcraft sponsor card always throws me off 😂 That’s a cute little Evap. Really like the controller outside and the fact that the customer is going with the network feature.
@KarbonKopy10 ай бұрын
That's just the cutest little evaporator.
@HVACRVIDEOS10 ай бұрын
Ha ha
@joshua.sookoor2025l10 ай бұрын
These are my favourite vidoes Freezer, Cooler and A/C installs, i learn so much from these videos 😊❤ thanks chris, I am only 12 but Its my dream to be a HVAC technician like you!
@The98deville10 ай бұрын
Got a notification for this video, then realized there were several new ones tonight, guess I'm going to bed late lol
@HVACRVIDEOS10 ай бұрын
Ha ha yeah these are all my videos for the next few weeks because I will be traveling to Ahr and the Symposium
@noskatehate10 ай бұрын
This video threw me off without Sporlan. Where's the quality, integrity, and tradition?? 😆
@Miketime96910 ай бұрын
Gone since COVID
@Travoz78710 ай бұрын
@@Miketime969 They were literally the sponsor card last video, saying they're "gone since covid" is wild. He just has 2 different sponsors that he works with because he enjoys their products.
@Miketime96910 ай бұрын
@@Travoz787 you missed the context of it completely . It was a joke because everything has got so shitty since Covid and cost cutting
@Travoz78710 ай бұрын
@Miketime969 ahhh makes sense, took you seriously. However, Sporlan would never do that to us with their quality, integrity, and tradition.
@Miketime96910 ай бұрын
@@Travoz787 their accounting department probably would
@zaccody698010 ай бұрын
Never seen an intelligen system installed like that. Didnt even know it was a thing. Much bigger fan of the control board being outside of the box. Have had nothing but problems with Russell's smart evaporaters constantly going through boards and i feel the moisture from the box has something todo with it
@zack991200010 ай бұрын
All they have to do is conformal coating placed in the board to waterproof it. They won't do it.
@gsuberland10 ай бұрын
PCB designer here. From what I saw on in the video, it looks like those boards have a thick conformal coating on them to prevent moisture from killing them, so I'd be surprised at it dying due to moisture. Maybe moisture buildup in the connectors, but that's pretty rare on vertically aligned boards. Should be fine here. Much more likely causes of failure are thermal cycling and bad power feeds.
@jamesboyd61749 ай бұрын
Thank you for walking through this This education will be forever in my pocket ❤
@ebfsystem9 ай бұрын
Great videos man,I wish my supervisor was not so afraid of technology and get us the proper training and tools,Im trying to save up so I can get the DTech leak detector and the press from the video, I appreciate all the time and effort you put on your videos! PS willing to relocate from Texas if you ever looking for techs ✌️🍻
@AARONJL9210 ай бұрын
I like that tip of breaking the line set. What i learned to do is p press the burr in with needle nose pliers. Works pretty well too.
@FrNMGuy10 ай бұрын
BRAZING MONTAGE!!!!!!! MY 3 YEAR OLD SON IS SO HAPPY RIGHT NOW!😊
@joeslinky10 ай бұрын
Your e year old son??
@FrNMGuy10 ай бұрын
@@joeslinky Woops! Fat lingered that one.
@FrNMGuy10 ай бұрын
@@joeslinky SEE WHAT I MEAN!
@joeslinky10 ай бұрын
@@FrNMGuy Lol
@dieselchevette10 ай бұрын
Nice install video. You set an example of how to do it all properly. That Carel EEV is a great part, and it was sweet to see a tech using the magnet tool to turn it open/closed. That tool is indispensable to rule out the controls vs the valve when things act up. It was great seeing you at the show as well. I'd venture that your customer here I bet will see their power bill drop a bit, as well.
@mikel28903 ай бұрын
My current HVAC system was installed in my house (built in 1972) in 1996 and it's a 3.5 ton system (2 story house, 2,000 sq ft.) I had some bids on getting the system replaced and the first bid was going to keep it a 3.5 ton but the second bid they wanted to up it to a 4 ton system. My system short cycles as it is (6 to 8 minutes running, 10 to 15 minutes off on a 90+ degree day, thermostat set at 73 degrees). I'm trying to figure out why a half a ton more would be better for my house when the current one short cycles. Probably just wanted to sell a slightly bigger unit to make more money no doubt. Really enjoying your vids btw!
@HVACRVIDEOS3 ай бұрын
You need a blower door test done on your house to figure out how bad the air leakage is than have a manual J load calculation done and you will know exactly what size your system needs to be!
@mikel28903 ай бұрын
@@HVACRVIDEOS Thanks for the reply! I am sure the air leakage is horrible in my house because of original windows and doors from 1972. When the furnace runs in the winter (I live in the midwest) your can feel the cold air draft being pulled in through the windows and doors.
@EdwardOrozco12Ай бұрын
Dang this is a really nice install 👌🏽👌🏽👌🏽🙌🏽🙌🏽. Will did a very nice job on the roof. P trap looks nice too
@kens.372910 ай бұрын
Keep up the Strong 💪 Efforts, Chris. 👍🙏
@EnderMalcolm10 ай бұрын
That is an adorably tiny evaporator. Edit: Coming back to the multi-system card. Another big selling point is that it allows very easy setup via internet-controlled monitoring systems in the future. Pop in an Ethernet cable and boom, it's hooked up to the monitoring system. Could even do a really simple alert-based system, text all the managers with the error code and current system temps. They will know immediately if there's an issue, rather than finding out 8 or so hours later when the ice cream is liquid.
@Powertampa10 ай бұрын
Yeah you could. You could also not do that and avoid giving the IT a headache in regards to network security. Only put things into a network if you absolutely need to. Less is more, don't need the beer getting warm over some idiot downloading malware to the network :)
@Mr42424242424242424210 ай бұрын
@@Powertampa That's why I prefer that IoT stuff run through its own dedicated gateway with no contact with normal network traffic. Preferably without the ability for anything outside to reach in, just it using a provider gateway to send emails or texts
@Jadrie110 ай бұрын
@@Powertampa Better idea is to, in advance, talk to the IT department and get their preference ahead of installation. A lot of teams are happy to get that sort of monitoring set up if the location would benefit from it, if they know well in advance: (NetSec might want it VLAN'd off to isolate its access, get a low voltage tech to run an ethernet drop to hardwire it, etc.,), it just requires communication with the other team ahead of time.
@gsuberland10 ай бұрын
@@Powertampa As long as you're only talking about outbound alerts and data reporting it's fine. Typically something like MQTT on the backend, feeding into a time series database and alerting system (e.g. PagerDuty). You wouldn't be giving this thing its own internet-facing IP address. My day job is doing security assessments on industrial control gear on stuff way higher price & risk than this, and lots of outbound telemetry is absolutely the norm these days. And the remote management stuff works the same way - the device sends outbound polls to a cloud service or does an outbound websocket connection (over TLS) for push messages, and it's all managed via that.
@davejohnsonnola153610 ай бұрын
Combination package beer / produce walk in..seasonal facility. Box holds good temp of 38F but mold on produce..strawberries are main culprit Need to coordinate with sous chef to rotate and toss product when beginning to show mold. Really need to start fresh and decontaminate entire box.
@AKStorm4910 ай бұрын
Definitely a neat tool from Heatcraft for idiots like me. Good video Chris.
@helmsajr10 ай бұрын
Awesome setup on wifi I love when you can use wifi set up on HVACR equipment. Great job Chris.
@oscalerup112910 ай бұрын
That’s really cool. I did two walk-in replacements this summer. I got both to use a digital controlled evaporator, we used Russell, I liked them they also have huge capacitors to close the EEV upon a power failure. If I did it over though I also would still like a LLS. The Russell evaporators came stock with Sporlan EEVs which are very interesting and different looking to me vs what I typically see. As usual the customer is already on a budget and I always insulted the liquid line since in both applications the new line sets went through a very hot attic.
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@Coffreek10 ай бұрын
If people are worried about controllers inside coolers, they may not be aware of the IPX rating system. If you really want overkill, you can always install a heater and dessicant dryer inside the enclosure.
@stephenbullock-yn3vh10 ай бұрын
Excellent install 👍
@krazy1z9 ай бұрын
Nice walk through with the Heatcraft!
@fshn7610 ай бұрын
I was wondering where the DTC Valve was on the compressor since it was a 448a system. Then remembered it was for a cooler. Used to dislike 448a but I have became a fan here lately. Tube and fin CONDENSOR are so much easier to keep clean.
@tschuuuls48610 ай бұрын
The argument in favor for the wifi card would be Email notifications when there are problems, but the product is not yet spoiled. Also interesting that that California mandates more efficient fans and blades, but doesn't mandate hot gas defrost (which probably would be better for your customers as it should be more powerful).
@johnwalker89010 ай бұрын
Good job Chris and crew.
@jasonjohnsonHVAC10 ай бұрын
With EEV'S it is not uncommon for low superheat. Especially with VRF....I have seen superheat as low as 0.5°....with VRF, Chillers etc. This Heatcraft is pretty slick. The "front end" you were looking at on your tablet is pretty cool....its cool to see HMI's being more mainstream in equipment. In heavy commercial and industrial this has been a "thing" for decades now. It can and does give a vast amount of information.....as long as you understand what it is you are looking at. That was also a nice clean install yall did. Great video as always Chris HOPE YOU GET TIME AWAY FROM PODCASTS TO ENJOY AHR AS JUST AN HVAC GUY. 🤘🤘🤘🤘🤘🤘
@HVACRVIDEOS10 ай бұрын
I didn’t book anything on Wed for Ahr so that is my day to actually explore the show
@CopperCowboy33310 ай бұрын
Amazing 🧜♂️ craftsmanship 👏.. as always 🎉
@mikeahs0610 ай бұрын
I worked for an HVAC supplier for years and when it came to the contractors they either hated or loved press fittings. Same went with shark bite fittings and pex pipe. It's either you love it or hate it no in btwn haha
@DelticEngine10 ай бұрын
Hey Chris, this was an excellent, very informative and helpful video that managed to squeeze in key points about a lot of parts of the system and factors involved. Well done! Regarding the networking communication, I would go with wired ethernet always and disable any wireless communication. This makes it much less likely for there to be issues with WiFi glitches and interference as well as removing the possibility of wireless hacking which can be shocking simple to achieve sometimes. Ideally, the cooler ethernet would be on the business intranet rather than a more general network that includes internet access, although this can be mitigated if the business has intelligent network management and knows how to configure it. It would then be possible to allow, for example a specific device, and only that device, that you or your business has to remotely access the cooler network interface and see what is going on and maintain decent network security.
@EverythingisFire10 ай бұрын
I love an Install video first thing Sunday Morning 🍵
@karnvir354210 ай бұрын
That is a great installation, i install ke2 evap efficiency it similar to that but the only question i got sir isnt this eev works as a solenoid too? I learn alot from your videos and it has made a better tech at field. Respect your effort and explanation in the videos.
@Marklopez36210 ай бұрын
It does also work as a solenoid. I’ve read a lot of people having problems with that though. He installed it to be more on the safe side and I’m guessing to extend the life of the eev.
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@shanebehm82513 ай бұрын
You know how many nozzles I've thrown away before I saw your video like five years ago! I felt so stupid.
@zekenzy648610 ай бұрын
Great Video. Thank you for sharing
@gordonrockafellow121110 ай бұрын
Walk in cooler humidity is more controlled by condenser evaporator match than system size. If you use factory match it is typically for 10 degree evaporator TD, which causes a fairly wet cooler. For a dry unit I will use a 15 or higher TD with electric defrost. I am in Florida where the humidity is high and a lot of places use walk in's in place of reach in's and the cooler door is almost open more than it is closed. If I use cooler factory unit sizing the cooler will not hold temperature with heavy traffic. The only problem with the high TD is having to use the electric defrost.
@mattgruber39332 ай бұрын
Great video! Did the mold stop?
@ezchoicelab990410 ай бұрын
I think is a good idea to bing the CAT 6 cable together with EXV and Transducer in the same box. And let IT to take it from there, instead of letting them in your controller box.
@deineroehre10 ай бұрын
Oh no, what happened to Sporlan? You took the Integrity, Quality and Tradition from us! ;-)
@josemartinez-457010 ай бұрын
Like your videos awesome work 👍! What size is that iPad I been wanting purchase one good case
@wtfux10 ай бұрын
You sped through the box sizing and didn't make a humidity adjustment despite harping about cardboard weakening, were the defaults for a keg cooler setup sufficiently dry as is?
@brianhenderson97902 ай бұрын
Love your videos. Why do you not install Trenton equipment. Pre built and by far way better than Heatcraft equipment. Just curious.
@HVACRTECH-8310 ай бұрын
Excuse my ignorance in this matter, I don't work on much refrigeration, but is that a common thing to have a fixed orifice downstream of the exv? What if it was a txv instead of a exv? I guess I don't understand why there's both a fixed orifice and expansion valve. I'm starting to work on more walk ins and freezers lately so trying to learn all I can. Great video btw as usual
@special_k-hvac10 ай бұрын
Talking about the nozzle? If so it's for even flow between the distribution tubes afaik
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@fischhead210 ай бұрын
Nice one. 6200 BTU? Even my mobile A/C has 12.000. Well, in summer its way to weak, its monoblock and the case heats everything more than it cools... Anyways, nice work and interessting video. Keep the good work. Greetings from Germany :)
@michaelkuprian0110 ай бұрын
Don't loose that pink crescent wrench at 23:42. It slid under the condenser when running power
@sw618810 ай бұрын
Better a tight crescent than a loose one.
@ed683710 ай бұрын
Just wondering on a shut down if the EEV is closed and the solenoid is closed any issues with liquid trapped between the two? if the box warms up you would have tremendous pressure between the two valves.
@Thermoelectric710 ай бұрын
I looked into this recently, pretty sure the solenoids will "leak" in the reverse direction, so any extra pressure will bleed back into the liquid line.
@deebawadat796110 ай бұрын
Good job Plz how down load heatcraft
@thejnelson8810 ай бұрын
In industrial refrigeration our Transducers come telling us not to mount upside down for that very reason. Oil messes with them so bad.
@steveH38410 ай бұрын
ive had inspectors demand i pressurize to 300 on these similar systems, one actually demanded the rated pressure on the system lmao. I actually won that argument!
@davidmcclare44310 ай бұрын
hi what was the reason that you installed a p trap on the refrigerant line?
@CameronKettner10 ай бұрын
Before replacing the equipment, have you considered putting a temperature data-logger in the box for a week or two, so that you can see the runtime on the current equipment and be able to more accurately calculate the capacity needed for the actual box and how its being operated?
@gregomyeggo452910 ай бұрын
Hi Chris, excellent video! I have a question. Where did you get that eev magnet? Who makes it? Thanks in advance!
@HVACRVIDEOS10 ай бұрын
I got it from going to a Heatcraft training class but carel sells them
@shanebehm82513 ай бұрын
You can't use the EEV as a pump down solenoid? I know the beacon system did years ago. Just curious
@HVACRVIDEOS3 ай бұрын
Yeah you can but I added the solenoid just for extra safety
@timelesspeach798410 ай бұрын
I love your videos
@Freezier134a10 ай бұрын
If it’s an intelligen why the solenoid valve Chris? Shouldn’t the Eev pump it down? Got my answer further in!
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@marcoferreira22610 ай бұрын
What size of tip do you use on your torch
@dmiestercommkitchentech304310 ай бұрын
Chris Im confused for the ambient temperature for outside of the walk in is that for the condenser location because you put the ambient temperature at 105°F and then put the condenser on the roof of the building not the roof of the walk in like I expected the ambient temperature on the roof should it be alot highed than 105°F.
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@ulairecantea923110 ай бұрын
Can you explain what is controlling your Solenoid in this situation since it's added by you. Thanks
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@SilentServiceCode10 ай бұрын
Yeah but you're *not* in Daylight Saving Time right now, that starts the second Sunday in March. If you would select the closest city instead (probably Los Angeles or something) it should just pull in DST settings for that locale.
@colinstu10 ай бұрын
39:10 don't beat yourself up on that. I'd much rather more folks be like that then not! Oh also that score 'n snap trick w/the copper was great.
@stephennichols481510 ай бұрын
How close was you on the run time you estimated 14 hours just curious nice video 36:25 36:28 36:33
@shine-cg9uf10 ай бұрын
❄️🇺🇸💪👍 great work n vid. HOW DID U KEEP THE EEV OPEN DURING BRAZING, WAS IT ENERGIZED? THANKS AGAIN
@special_k-hvac10 ай бұрын
Come from the factory in an open position
@shine-cg9uf10 ай бұрын
@special_k-hvac thanks for the feedback much appreciated
@HVACRVIDEOS10 ай бұрын
They come open from the factory
@shine-cg9uf10 ай бұрын
@HVACRVIDEOS thanks for the feedback Chris much appreciated
@preece758410 ай бұрын
With an EEV installed is the solenoid valve needed? Wouldn’t the EEV close when needed and act as the solenoid?
@preece758410 ай бұрын
Never mind, memo to self watch entire video before commenting, you answered my question at the end
@bradgoodale3249Күн бұрын
still not a fan of 2 speed evap fans,caught me of guard also Chris the start of the video no sporlan.🤣🤣
@thegoodguy86710 ай бұрын
38:59, is why he installed the liquid line solenoid valve.
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@ThePowerofElectricity10 ай бұрын
Wait wait wait... That's not right. This video isn't sponsored by Sporlan...? Quality, Integrity, Tradition? Has my life been a lie? It's Heatcraft refrigeration... That can't be. Who are you and what have you done to Chris?
@jasontexter172110 ай бұрын
I've never seen one of these with a solenoid coil, whats that for??
@jasontexter172110 ай бұрын
I've never seen an intelligen or QRC with a solenoid valve.... Is that to mitigate when those crappy carel valves stick open slightly and leak by 🤣🤣🤣
@stephengalante29735 ай бұрын
havent seen old Tecumseh condensing units in a minute
@theashgamer40010 ай бұрын
why heatcraft this brings me back to old days
@robholmes238110 ай бұрын
Hopefully the configuration includes changing the wireless password. Otherwise someone in the area can connect and change what they like using the default password and service code.
@Blasterxp10 ай бұрын
Just add 4g simcard, and offer the customer remote management and setup alerts!!!
@tysonforfreedom650710 ай бұрын
I must have missed it but how was the solenoid coil wired? Is there a connection on the controller or…?
@henryahmed10 ай бұрын
Yes, there is a set of dry contacts in the board that you can run the solenoid through it.
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@cayden922410 ай бұрын
Why did you install a p trap on the suction line?
@HVACRVIDEOS10 ай бұрын
It helps with oil return
@justme538410 ай бұрын
Unless you already did, you should change the default WiFi password or someone will definitely connect to it and have their way with it
@Rambogner10 ай бұрын
Heatcraft muscling in on Sporlan, who do they think they are!
@HVACRVIDEOS10 ай бұрын
Sporlan is not going anywhere they are still my main Sponsor
@mjboy879010 ай бұрын
How you go to an install so unprepared needing bolts p trap and more
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@rickybobbyracing10 ай бұрын
Why a solenoid and an eev? I've never seen that done before
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@EverythingisFire10 ай бұрын
Sorry to butt into your search history. Are you trying to expand or re-locate to Montana or something? :)
@SOU690010 ай бұрын
I like how the date on the controller defaulted to my birthday.😅
@AErefrigeration9 ай бұрын
Theres mold because the damn manager doesnt know how to clean
@TrumpsEarBandage3 ай бұрын
They know, they just dont care
@patriknilsson217510 ай бұрын
I have never installed a solenoid valve on an eev system, the eev do both the solenoid and txv's job. Even on CO2 systems with eev there's no solenoid valves, just the eev.
@HVACRVIDEOS10 ай бұрын
Yeah I did it for redundancy
@analogmoz10 ай бұрын
Doesn't the EEV make the solenoid redundant?
@HVACRVIDEOS10 ай бұрын
Yea
@HVACRVIDEOS9 ай бұрын
I will discuss this live this evening 1/29/24 @ 5:PM (pacific) on KZbin come on over and check it out kzbin.infon2yE2N8tLZE?feature=share
@jo652010 ай бұрын
I've never seen a 1 fan evaporator
@thomasmann35609 ай бұрын
Dude the new EVAP was so much smaller then the old one!
@HVACRVIDEOS9 ай бұрын
Yeah that’s because I sized it properly
@natepeterson714510 ай бұрын
No more Galaxy Tab Chris?
@anthonyriddick984210 ай бұрын
U kinda burnt that pipe up lol😂 But good installation
@djgeorgevdg10 ай бұрын
That socket for the glycol unit isn't earthed, That needs sorting ASAP
@glennschlorf128510 ай бұрын
Press fittings might be okay on non pressurized stuff.... for pressurized things better off soldering...
@_iLLuSiv3_10 ай бұрын
Not true, we use press fittings for anything, including domestic water, heating water, chilled water, and glycol systems. They have never failed us, although when Pro-Press first came out, I was skeptical of them for the longest time.
@hatokirai-desu10 ай бұрын
no sensor at 30:16 wifi names I guess 👀
@Ariccio12310 ай бұрын
39:08 oh ya but I dont see you using torque screwdrivers yet!
@the_expidition42710 ай бұрын
How
@grandinosour10 ай бұрын
Brazing near all that cardboard?
@AErefrigeration9 ай бұрын
Inteligen= over-enginered. Why not use a simple Ranco ETC? And DTAV40?
@HVACRVIDEOS9 ай бұрын
Government energy mandates are shaping the industry and pushing it in the direction it’s going
@jordanhenshaw10 ай бұрын
Looks like my comment got auto-removed since it wrote out IP addresses, but it gives the IT reason why you've had difficulties connecting to devices with wifi. Basically it's about subnet masks.
@masonallermann127510 ай бұрын
noooooooooo sporlan got replaced
@Jilocasindragon7 ай бұрын
It's not a multi system, it's a moldy system :D
@fadingbeleifs10 ай бұрын
Twice as fast as a commercial bunn coffee maker.. 1/10 of the price!
@steveblake876610 ай бұрын
635 thumbs uP
@hampter77910 ай бұрын
no quality,integrity nor tradition!
@natepeterson714510 ай бұрын
They were all oversized because of the global warming scare.
@ralphwoodard60910 ай бұрын
I see you’re still improperly, soldering the joints and wasting way too much solder where it could look and work a lot better if you just use less.
@HVACRVIDEOS10 ай бұрын
Yeah I’m a stubborn creature of habit
@jollygreen463910 ай бұрын
Here you go again, Ralph. Why don’t you do a video of your own and show us all how to do it your way?
@sw618810 ай бұрын
@@jollygreen4639 The internet is full of people who like to moan, complain and criticize others. All talk and no walk.
@jollygreen463910 ай бұрын
Oh I know that. This guy does the same post when Chris brazes in his videos. But look at that guys profile. I say he’s not in the trade, never was. So I guess me saying what I said to him, it’s time for him to “educate” us all. He can put up or shut up, would you agree? I’m not counting on it though. Lol