I have a 26 Joule energizer hooked up to 830 ft of poultry netting and the connector from the enegizer to the netting burned through the netting. My goats figured out that the power was off and two of them stuck their heads through the netting and got stuck and choked themselves. I think the problem may be a combination of a lot of Joules connected to a relatively small fence and the ground being so dry that I am not getting a good grounding. I bought a better connector that has more surface area and left a water hose barely running near the grounding rods. I think the best solution will be to replace the netting with high tensile wire.
@PlaneViewFarm
@PlaneViewFarm Ай бұрын
I've never had much luck with netting. It always seems to short out. I had the same thing happen with a goat kid about 5 years ago. I quit using it after that.
@myragrapa6973
@myragrapa6973 3 ай бұрын
Nice video
@lustysteve1420
@lustysteve1420 6 ай бұрын
Can I wrap the electric wire around a wood post or do I have to buy a insulator
@PlaneViewFarm
@PlaneViewFarm 6 ай бұрын
A bare wire will ground out on the wood post, especially when it gets wet. You can use wrap around insulator tubing instead. It's a little bit cheaper than individual termination insulators. kencove.com/fence/detail.php?code=I40-100
@theBakersonafewacres
@theBakersonafewacres Жыл бұрын
9:10 can you elaborate more on that? I've never heard or thought of that. I'm planning on getting a much larger than currently needed charger, but I'm also adding on a lot of fencing, but in stages. I don't want to damage an expensive unit.
@PlaneViewFarm
@PlaneViewFarm Жыл бұрын
I probably should have done that in the video. 🤦‍♂️ Being oversized for the fence system can be hard on the internals of some of the cheaper equipment. If you buy a high quality charger, you'll likely be ok.
@mjohnson4185
@mjohnson4185 Жыл бұрын
I bought a really powerful energizer and it has worked out pretty good. I do think that being oversized causes it to "find" weaknesses in your system. For example, I've had it burn through some of my cheap tubing insulators. But the advantage of the powerful system is that it burns the weeds / kills the grass and weeds so that you don't have to trim as much. For me, it's worth it to have the big joules.
@solschwartz7119
@solschwartz7119 10 ай бұрын
​@@PlaneViewFarmcan a cracked insulated cause it to ground out. Even if the wire is not completely against the post
@PlaneViewFarm
@PlaneViewFarm 10 ай бұрын
@@solschwartz7119 Yes it can! It can arc across and ground out. That's a really good question. I wish I had included that in the video.
@solschwartz7119
@solschwartz7119 10 ай бұрын
@@PlaneViewFarm thank you
@tomcopeland6424
@tomcopeland6424 4 ай бұрын
I bought a 26 Joule energize and currently have it hooked up to 830 ft of poultry netting. I know that is more joules than needed but I’m planning on fencing off about 30 acres with additional cross fencing. Right now, the netting is touching grass in several area and I hear a lot of clicking. I’m concerned it might catch the grass on fire. Is that something I need to be concerned about? Will adding more ground rods reduce the risk?
@PlaneViewFarm
@PlaneViewFarm 4 ай бұрын
Fire really isn't an issue with modern energizers because the current is pulsing. Older energizers had an issue with fire because the current was continuously flowing. The only real risk might be if the grass is extremely dry and the wire contacts something that might cause it to throw a spark. Even then, the risk is low because that spark isn't likely to be hot enough to start a fire. I hope this helps.
@leroygooding6954
@leroygooding6954 6 ай бұрын
can you touch tester to electric wire and steel post to test the fence
@PlaneViewFarm
@PlaneViewFarm 6 ай бұрын
Yes
@CEGEN2P
@CEGEN2P 4 ай бұрын
I noticed your ground wire was attached straight to tpost with clip does this help ground
@PlaneViewFarm
@PlaneViewFarm 4 ай бұрын
Good question! It does provide some grounding for the system, but not much for a couple of reasons. The posts don't get deep enough to provide much ground contact, while a grounding rod will be at least 6 feet deep, if not more. Also, the wires are not fixed tight to the posts with the clips. They are just loose enough to expand and contract. That allows for breaks in the flow of current back to the energizer through the ground. I hope that helps.
2024 Fall Update - Heart Attack
3:58
Tines and Trails Outdoors
Рет қаралды 26
Real Farmers Do Chores In Shorts AND Why We Clip Our Pastures
13:35
Worst flight ever
00:55
Adam W
Рет қаралды 30 МЛН
Electric Fence 101: Pros/Cons and Essentials
16:16
Rolling "O" Farm
Рет қаралды 56 М.
Greg and Joel explain how to install a proper grounding system for electric fence.
15:13
Greg Judy Regenerative Rancher
Рет қаралды 36 М.
How To Build A High Tensile Electric Fence
10:59
Plane View Farm
Рет қаралды 22 М.
Expert Tips For Your Electric Fence!
9:28
Farm Learning with Tim Thompson
Рет қаралды 26 М.
HOW TO INSTALL ELECTRIC FENCE FOR SHEEP AND COWS
14:41
the Shepherdess
Рет қаралды 64 М.
A Fool's Errand? Finding A Fault In My Electric Fence
8:18
Plane View Farm
Рет қаралды 361
How to find the short in your electric fence. We try the Zareba Fence Doctor.  Does it work?
6:31
How To Dig The Perfect Post Hole
16:26
SWI Fence
Рет қаралды 520 М.
Say Goodbye to Hassle; Electric Farm Fencing Tips
5:31
Farm Learning with Tim Thompson
Рет қаралды 9 М.
3 PHASE MOTOR TESTING - how too PROPERLY
39:04
Actual Electrical Content with Jamie blatant
Рет қаралды 36 М.