Пікірлер
@collettbuilt8569
@collettbuilt8569 2 ай бұрын
How do you release the tension to bring the rams back down to reconnect the pipe? We had a base plate break off and need to bring the rams back down to reconnect the piping on a running unit that we cant bring down.
@LISEGAIncUSA
@LISEGAIncUSA 13 күн бұрын
Please contact us at [email protected]. We will connect you with an expert who can get more information about your specific situation and walk you through the process to safely perform the necessary adjustments.
@josealbertopotencianoavalo3985
@josealbertopotencianoavalo3985 2 ай бұрын
TENGO DUDA EN CUANTO A LA CALIBRACION DEL SOPORTE MODELO 11
@LISEGAIncUSA
@LISEGAIncUSA 13 күн бұрын
If you have specific questions or would like more information regarding type 11 constants, please feel free to email us at [email protected]. Thanks!
@jonathana.4187
@jonathana.4187 2 ай бұрын
Hello, does this come pre-locked that needs to be released similar to Spring Supports?
@LISEGAIncUSA
@LISEGAIncUSA 13 күн бұрын
Snubbers do not come locked. Snubbers come packaged very carefully to prevent any damage during transport. They can be installed very easily and are ready to function. If they happen to be locked due to a sudden "event" such as shifting during transport, they will unlock and be functional without any outside intervention. Please feel free to email us at [email protected] if you have any questions or would like additional information regarding snubbers. Thanks!
@tornet3464
@tornet3464 5 ай бұрын
The concept of the constant support is interesting !
@LISEGAIncUSA
@LISEGAIncUSA 5 ай бұрын
Thank you, they truly are a valuable tool in the world of pipe supports. You may be interested in some of the other videos we have posted, particularly about constant hangers. Feel free to explore our channel and our website. If you have any questions, feel free to contact your nearest LISEGA representative.
@fariddabo
@fariddabo 6 ай бұрын
Good evening, sir. You can give me these lessons in French in pdf format or in any shape and thank you very much.
@LISEGAIncUSA
@LISEGAIncUSA 5 ай бұрын
Unfortunately, we cannot supply the text in French at this time. If you have any questions, please feel free to contact your nearest LISEGA representative. You can locate them on our website at www.LISEGA.com.
@fendix975
@fendix975 11 ай бұрын
Excellent vudeo
@eng.mahmoudsaad653
@eng.mahmoudsaad653 Жыл бұрын
If I want one variable sp. Support only the spring . Can I buy from your company quickly???
@LISEGAIncUSA
@LISEGAIncUSA Жыл бұрын
Yes you can. Please contact your nearest LISEGA office and they will process your request quickly.
@samirpashayev5946
@samirpashayev5946 2 жыл бұрын
this is very helpful. thank you!
@LISEGAIncUSA
@LISEGAIncUSA Жыл бұрын
You're very welcome!
@aaarbee2415
@aaarbee2415 2 жыл бұрын
How can you adjust a load on variable spring hanger at site, when spring has plus or minus 5 % load tolerance on spring rate , it can be calibrated only on test rig for accurate new load, site adjustment not Recommended.
@LISEGAIncUSA
@LISEGAIncUSA Жыл бұрын
When we set the spring at the factory we use the ACTUAL force the spring is exerting on the test bench. We do not use, or even have, a load scale on the variable spring itself. By computing the desired new force using the mathematical process explained in this video (which is much more precise than using a load scale) the new force will be accurate enough for most situations. If the new desired force is REQUIRED to be exact then we recommend sending the spring to our factory and resetting the load on our test bench.
@aaarbee2415
@aaarbee2415 Жыл бұрын
@@LISEGAIncUSA noted ✅️ thanks
@rogeriopinho4736
@rogeriopinho4736 2 жыл бұрын
These videos are very important for when you have doubts.
@abaskaraji8283
@abaskaraji8283 2 жыл бұрын
بسلام برنامه یوتیوب را دوست دارم امیدوارم روزبه روز بیشتر از دیروز باشد مچکر ممنون
@leecoen2577
@leecoen2577 3 жыл бұрын
Thank you for the excellent videos Jon..learned tons in 4 minutes..
@LISEGAIncUSA
@LISEGAIncUSA Жыл бұрын
Glad to help!
@AMerGogogo
@AMerGogogo 4 жыл бұрын
Understood this video.. My question, how to know when to adjust the load using those two bolt and why not adjusting using the turnbuckle. Thanks in advance
@hunny1400
@hunny1400 3 жыл бұрын
Basically the load adjustment bolts are intended for high variation in load change with minimal deviation in load point elevation. When minor correction is needed with respect to altering the load point elevation along with slight deviations in load is not worrisome, it should be tried with turn buckle.
@LISEGAIncUSA
@LISEGAIncUSA Жыл бұрын
The red and white marks on a constant force spring show the calculated hot & cold POSITION of the spring. The marks do not indicate the load the spring is applying. The LOAD the spring is applying on the pipe remains the same throughout the entire range of travel (this is much different than on a variable spring). Changing the dimension using a turnbuckle will only change the position of the pipe, but not the load the spring is applying. Changing the position of the pipe will shift the pipe load to nearby springs. The only way to change the load that this particular spring is applying is by using the two load adjustment bolts.