Thanks a lotttt sir, can you help me how to add a fence connected to the ground grid into the etap simulation, then how to run it
@kumar80524 күн бұрын
Sir Please share some oti files for analysis
@Thiswordlylifeisatest9 күн бұрын
Transient reactance comes in picture during motor starting .
@SalvarockA9 күн бұрын
do you know where I can get a list of LV molded-case circuit breakers library list supported in each Etap Version please?
@solmaroo658011 күн бұрын
Can you share this excell file? Thanks for the explanation.
@NadiraAbdRazak24 күн бұрын
hi, can u share on how u differentiate between 4000K & 6500K CCT
@UsmanShah-gu7dw25 күн бұрын
Great
@TheSurgeArrester25 күн бұрын
What is a tmsh?
@praveenvarma136926 күн бұрын
Is it ok if we use Delta / Delta transformer on the MV side?
@AsimAli-u7m28 күн бұрын
Sir explane videos in hindi ...
@hplus-engg29 күн бұрын
WHAT ABOUT THE GROUNDING CONFIGURATION FOR BOTH THE TRAFOS ( THE NEUTRAL POINT SAME OR DIFFERENT NEUTRAL GROUNDING POINT )
@ParisHaqueАй бұрын
Could you give me that Excel file???
@matakuchanel4093Ай бұрын
How to check neutral voltage?
@sittichaiboonkongАй бұрын
Thank you so much, easy for understanding _/i\_
@hanial-shadadi9122Ай бұрын
WHY THE NEGATIVE TAPPING INCREASE THE V, WHILE IN REALITY IT IS THE POSITIVE TAPPING IS THE ONLY WAY TO INCREASE THE SECONDARY VOLTAGE???
@Sahilkumar-se2psАй бұрын
sir kindly share the spread already sent request on mail
@ignaciovasquez1601Ай бұрын
Do you know if it is possible and how to filter results before exporting to excel? for example by zone or area. If it is in another of your videos i'd love if you point it out!
@naseemserwer8011Ай бұрын
video is still, re-record this video
@SmartEducareАй бұрын
Okay, will do that, thanks for the feedback
@naseemserwer8011Ай бұрын
Please re-record this video due to background humming noise throughout the entire video
@SmartEducareАй бұрын
Sure
@naseemserwer8011Ай бұрын
Dear Sir, highly professional and practical, great approach.
@SmartEducareАй бұрын
Thank you for the kind words!
@reincwanАй бұрын
How to do simulation for fully maximized lump load? Which parameters should I change?
@plqp770Ай бұрын
@SmartEducare Have you tried to calculate the single-phase fault current for the Y/Yn connected transformer? Despite the secondary winding neutral being grounded, Etap shows that the fault current is zero, and un-faulted phases' voltages are equal to the line voltage - the same as for isolated neutral or delta-winding transformer with a 1-phase fault.
@yosadigunaАй бұрын
how to find value kAsc & X/R in power grid?.
@PrateekSrivastava-u9vАй бұрын
please share the excel sheet
@ramisiyam24442 ай бұрын
can you please share the excel sheet?
@sonipratama61152 ай бұрын
i love your content broo keep up the good work
@SmartEducareАй бұрын
Appreciate your kind words!
@pauloaugusto312 ай бұрын
THANKS! GREETINGS FROM BRAZIL
@SmartEducare2 ай бұрын
Thanks a lot for the feedback! Stay tuned..
@rakeshchandrapatra29232 ай бұрын
plz share excell file
@youssefshaaban34042 ай бұрын
Hello Engineer, could you please tell me where I can find the complementary video following the one above?
@suryassunshine64692 ай бұрын
Dyn1 transformer cannot be paralleled with Dyn11 transformer. In reality, there will be a phase difference of 10Deg between the voltage of both transformer and this can lead to hug circulating currents if paralleled. ETAP does not give an error or warning for when two transformers with different vector groups are paralleled.
@ThomasAntonius-y5v24 күн бұрын
You must activate "apply transformer phase shift" first inside edit study case to get the impact..
@EJAMITONATHANIELMMSU2 ай бұрын
Hello where did you downloaded the catalog for Philips? Thank you
@ny-iw9gj2 ай бұрын
Thank you very much! It is a very useful video! May I know if the setting in actual case is 4 x 300 / 5A PCT 10P10, what will be the settings in Phase, Neutral, Ground and Sen. Ground in ETAP?
@praveenvarma13692 ай бұрын
In case of MV/MV Transformers if there are no MV motors/loads, can we use Delta/Delta Transformers . any disadvantages / advantages?
@mwncc65282 ай бұрын
Sir sorry, I have question in cable sizing. What is the meaning of no of runs? Example: 5R/3.5C/240sqm/XLPE and 1R/3.5C/25sqm/XLPE Thank you Sir
@SandeepYADAVggn2 ай бұрын
Irrespective of vector group, load sharing is not showing circulating currents in Etap for vector groups which are not to be operated in parallel. Why? I have tried many transformers with unmacthed vector groups in parallel but in none group etap shows circulating current. Etap simulate normal load sharing for such parallel operation.
@ThomasAntonius-y5v24 күн бұрын
You must activate "apply transformer phase shift" first inside edit study case to get the impact..
@ammarbinmaher61832 ай бұрын
How did you choose the pick up current 1.05 ? As I know, it suppose to be the normal load current * 1.20 , which is huge. Thanks
@jenmatt66992 ай бұрын
Email id pls
@GrowSelf-i7y3 ай бұрын
You are Gem
@SmartEducare2 ай бұрын
Thanks for your compliment
@biniyamabiy77503 ай бұрын
How can we get excel
@Anaskamal234-r4s3 ай бұрын
is their anyone who can help me out for the installation of etap
@demetriusdemarcusbartholom8063Ай бұрын
Yes
@debanjanacharya3 ай бұрын
sir can you please post the link of the video where you have detailed the concept of trip device in low voltage circuit breaker?
What will be the fault current to be considered for ground grid conductor sizing?
@kaisalvi78503 ай бұрын
This channel is very extraordinary in explaining, good content also for someone who is still a beginner. he kindly also shared the entire file on this video. hopefully fast growing and successful your youtube channel. PLZ make more useful video and manual calculation (ETAP) SOFTWARE THANKS
@SmartEducare2 ай бұрын
Thank you for the kind words and support!
@kaisalvi78502 ай бұрын
@@SmartEducare plz continue more video with example etap
@beckenbauer19743 ай бұрын
Is there any way to simulate Transient voltage recovery after Generator fault clearance?
@sahilbhagat43563 ай бұрын
Lighting loads or sockets which may or may not be connected to motor shall be considered as static load?
@kaisalvi78503 ай бұрын
very nice explained with perfect calculation plz make more etap videos with your projects and also share all excel sheets
@ehabshabaan78663 ай бұрын
Hi , what about the min. gap conductors/phases. And min gap conductors (L-G). Please clarify how we can get the above info
@Whitetooth10303 ай бұрын
Kind of pointless video. Why not explain the reasons for selecting the values you did ? You didn’t explain the pickup range values, curve type, or how to coordinate with existing data.
@SXF-ri6rk4 ай бұрын
Your english is so frightened that I can hear nothing。。。。。。。。。。。