Where’s the flue pipe on the furnace?
@khw71471
@khw71471 5 ай бұрын
Beautiful repipe!
@none8901
@none8901 7 ай бұрын
It s a video in which the author shows he knows how to instal a dunkirk boiler and makes VERY sure the viewers will not know.
@NROhvac
@NROhvac 7 ай бұрын
Good clean work. You didn’t put in purge stations on return line from what I can tell, that’s really the only bad thing i seen, otherwise great job
@Jessedog11
@Jessedog11 8 ай бұрын
why would you use a dielectric union on a Heating return?
@mikev.1034
@mikev.1034 Жыл бұрын
👍👍
@johnguerrero4305
@johnguerrero4305 Жыл бұрын
Why are all plumbers stuck on having the circ pump on the supply?!!! I swear it drives me nuts!!! Weil McClain clearly lists two locations on their boiler, you can have the circ. Pump: on the supply and on the return. They will re-pipe the whole boiler to make sure the pump is on the supply!! In 35 years of installing boilers, I’ve never installed a pump on a supply and I’ve never had flow issues! Please stop!!!
@jeffreyjohn2037
@jeffreyjohn2037 Жыл бұрын
It doesn't matter where the circulator is. Just make sure that you have a good air separator.
@joshwee26
@joshwee26 2 жыл бұрын
Just got my installed this afternoob
@tomk3635
@tomk3635 Жыл бұрын
How’s it running? Thinking of getting one…
@JamesSmith-rl7nb
@JamesSmith-rl7nb 2 жыл бұрын
Bas location for make up water??? Injection should be on supply line after pump discharge to insure air removal from purge station on return line or pump inlet
@tomjohnson1190
@tomjohnson1190 2 жыл бұрын
1) Why change the boiler ? and 2) why not replace each zone valve with circulating pumps.? Very informative video. Thank you.
@smity9089
@smity9089 2 жыл бұрын
Whats the deal with the stage 2 heating with this unit? Mine has never kicked into 2nd stage heating even when the temperature is close to 0. What coukd be the issue?
@soyouknowme9582
@soyouknowme9582 Жыл бұрын
Verify W1 & W2 low voltage terminals are not tied together and that the thermostat has the ability to run more than 1 stage of heat.
@wise1xo
@wise1xo 2 жыл бұрын
Nice install though
@wise1xo
@wise1xo 2 жыл бұрын
Heads fins look a bit banged up already lol u have a struggle getting it up those stairs?
@horacioaliaga4661
@horacioaliaga4661 2 жыл бұрын
any idea about this noise: kzbin.infoSFVXex8f5Jw?feature=share
@dsciarrino3663
@dsciarrino3663 2 жыл бұрын
Sweet
@naturalhealing9970
@naturalhealing9970 2 жыл бұрын
Love it. Am planning to put a conventional in my home. Everyone is trying to talk me into a condensing boiler and I have heard from across the country they are nothing but a head ache.
@TheLittleSamurai
@TheLittleSamurai 2 жыл бұрын
Awesome video, thanks!
@andrewjohnson2561
@andrewjohnson2561 3 жыл бұрын
American Standard furnace
@Ed-gz6lx
@Ed-gz6lx 3 жыл бұрын
I have a nest 3rd gen. Using a mclain Cga bolier. Where would the c wire connect on this boiler?
@GOSPEL_of_the_KINGDOM_REDBOOK
@GOSPEL_of_the_KINGDOM_REDBOOK 3 жыл бұрын
Doing a similar project as a DIY in the south; could you provide a components list on the magnetic and air filter parts.
@unadillamoto
@unadillamoto 3 жыл бұрын
Looks Great, nice work. 👍🏻
@carrierproductions315
@carrierproductions315 3 жыл бұрын
Its a Mitsubishi with a Trane logo on it
@jamesblauw6928
@jamesblauw6928 3 жыл бұрын
Nicely done...hot water heat is the best.
@jamesblauw6928
@jamesblauw6928 3 жыл бұрын
What an improvement! Beautiful installation, too.
@ianwilson1986
@ianwilson1986 3 жыл бұрын
I need this set up only difference is my pump is on the supply
@kjstass50
@kjstass50 3 жыл бұрын
xr13 in2019?
@GroupUnders
@GroupUnders 3 жыл бұрын
Accuclean would have been better than that air cleaner.
@jokarpinski22
@jokarpinski22 3 жыл бұрын
Do you know the model number for this unit? (probably a little late asking)
@sparky3869
@sparky3869 3 жыл бұрын
Nice solder job. Question how well does the magnet air separator work? If you have all coper, it should not really have any metal fragments in the system. Maybe some from the boiler and piping.and or cI radiators. Nice job. I
@stevestratton1888
@stevestratton1888 3 жыл бұрын
After the repiping you did on this boiler you probably wouldn’t even have to purge, the new air separator and pump location would most likely be enough to eliminate any air in the system on its own.
@stevestratton1888
@stevestratton1888 3 жыл бұрын
Very nice install. You don’t see a lot of residential installs with this level of craftsmanship! Excellent soldering! I’m happy to see I’m not the only one staying away from pro press 👍🏻
@mariopaz639
@mariopaz639 3 жыл бұрын
Nice clean install. What’s something like that cost roughly?
@yalcharan
@yalcharan 3 жыл бұрын
Do you need to change any setting for heating inside like HP1 etc
@masterofdisaster203
@masterofdisaster203 4 жыл бұрын
How long did or does it take you to get down below 300 microns with a single zone mini split? They take forever with such small lines.
@masterofdisaster203
@masterofdisaster203 4 жыл бұрын
Why didn’t you go out the left side of the unit and then you wouldn’t have to run line hide across top of window? Looks good not complaining. Also a good video.
@mikegreenfield3888
@mikegreenfield3888 4 жыл бұрын
What website do you use for the sticker on side with your number on it , that’s genius I’m a hvac tech in North Carolina
@channelcatchaser9426
@channelcatchaser9426 4 жыл бұрын
Are you a one man operation? Thanks for the video
@TheBuildingExpert
@TheBuildingExpert 4 жыл бұрын
Nice job bro.
@blackpine6693
@blackpine6693 4 жыл бұрын
Is there a reason why you set the air vent so high?
@moresmores9172
@moresmores9172 4 жыл бұрын
do monoflow systems with finned tube baseboards react well to purging or dou you have to vent each baseboard?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 4 жыл бұрын
It depends on the purging setup and how large the system is. On this system I was able to purge all the air at the boiler because I setup the purge the way I wanted it and the system itself was small. But most of the times on a repair the boiler has a basic purge setup that is pretty useless so it usually requires purging each loop at the radiation to get all the air out.
@moresmores9172
@moresmores9172 4 жыл бұрын
Why is the air vent so high on the supply side? Does this increase the effect ?
@treke08
@treke08 4 жыл бұрын
what is the component wired in just above the temp/press gauge on the outlet?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 4 жыл бұрын
It's a Low water cut out. They are required by code.
@treke08
@treke08 4 жыл бұрын
@@jpheatingcoolingllc.6620 Thanks. Do you usually use 120V or 24V power to low water cut out on a Weil-McLain CGI boiler?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 4 жыл бұрын
@@treke08 I use the 120v units.
@treke08
@treke08 4 жыл бұрын
@@jpheatingcoolingllc.6620 Thank you
@stifflers69mom1
@stifflers69mom1 4 жыл бұрын
I Was told to install the Circulator pump pushing into the boiler so it doesn’t see the high heat it will lengthen the life of the circulator.....honestly I think it’s BS because my previous one is set up like yours and it’s 31years old....I see You did it the other way could you explain your opinion on that?
@garyalex4281
@garyalex4281 4 жыл бұрын
Looks good
@doug995.
@doug995. 4 жыл бұрын
The pump and zone valves are normally better on the return side of the boiler as the water is cooler on the equipment. Good job.
@Rainmaker88
@Rainmaker88 4 жыл бұрын
Debateable if that was ever the case but now a days there’s 0 reason to not pump away
@robertoconnor456
@robertoconnor456 4 жыл бұрын
Nice job!
@Bob.W.
@Bob.W. 5 жыл бұрын
Pumping away. Holohan would concur.
@PBS-nm1uu
@PBS-nm1uu 5 жыл бұрын
why did you choose this pump compared to 007e ?? thanks for the video. how did you include the storage tank ??
@ML-lg4ky
@ML-lg4ky 5 жыл бұрын
What was the complaint for changing the piping? Airbound?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 5 жыл бұрын
Yes