WEIL-McLAIN CGA Repair on Monoflo system.

  Рет қаралды 5,977

JP Heating & Cooling, LLC.

JP Heating & Cooling, LLC.

Күн бұрын

Пікірлер: 18
@khw71471
@khw71471 5 ай бұрын
Beautiful repipe!
@doug995.
@doug995. 4 жыл бұрын
The pump and zone valves are normally better on the return side of the boiler as the water is cooler on the equipment. Good job.
@Rainmaker88
@Rainmaker88 4 жыл бұрын
Debateable if that was ever the case but now a days there’s 0 reason to not pump away
@johnguerrero4305
@johnguerrero4305 2 жыл бұрын
Why are all plumbers stuck on having the circ pump on the supply?!!! I swear it drives me nuts!!! Weil McClain clearly lists two locations on their boiler, you can have the circ. Pump: on the supply and on the return. They will re-pipe the whole boiler to make sure the pump is on the supply!! In 35 years of installing boilers, I’ve never installed a pump on a supply and I’ve never had flow issues! Please stop!!!
@jeffreyjohn2037
@jeffreyjohn2037 Жыл бұрын
It doesn't matter where the circulator is. Just make sure that you have a good air separator.
@JamesSmith-rl7nb
@JamesSmith-rl7nb 2 жыл бұрын
Bas location for make up water??? Injection should be on supply line after pump discharge to insure air removal from purge station on return line or pump inlet
@jeffreyjohn2037
@jeffreyjohn2037 Жыл бұрын
You obviously don't know what you're talking about. Regards, third generation oilman guru and steam heating contractor.
@ianwilson1986
@ianwilson1986 3 жыл бұрын
I need this set up only difference is my pump is on the supply
@moresmores9172
@moresmores9172 4 жыл бұрын
do monoflow systems with finned tube baseboards react well to purging or dou you have to vent each baseboard?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 4 жыл бұрын
It depends on the purging setup and how large the system is. On this system I was able to purge all the air at the boiler because I setup the purge the way I wanted it and the system itself was small. But most of the times on a repair the boiler has a basic purge setup that is pretty useless so it usually requires purging each loop at the radiation to get all the air out.
@ML-lg4ky
@ML-lg4ky 5 жыл бұрын
What was the complaint for changing the piping? Airbound?
@jpheatingcoolingllc.6620
@jpheatingcoolingllc.6620 5 жыл бұрын
Yes
@mikev.1034
@mikev.1034 Жыл бұрын
👍👍
@stifflers69mom1
@stifflers69mom1 5 жыл бұрын
Dose a mono flow system mean that it’s only one zone?
@ML-lg4ky
@ML-lg4ky 5 жыл бұрын
No Name mono flow is the term used for special fittings that feed supply and return water to the emitters off 1 loop.
@stifflers69mom1
@stifflers69mom1 4 жыл бұрын
Mike L thank you
@stevestratton1888
@stevestratton1888 3 жыл бұрын
After the repiping you did on this boiler you probably wouldn’t even have to purge, the new air separator and pump location would most likely be enough to eliminate any air in the system on its own.
@jeffreyjohn2037
@jeffreyjohn2037 Жыл бұрын
Wrong. You must purge the system. You 🤡
Boiler Training Class, Parts, Operation, Zoning, Explained!
22:49
AC Service Tech LLC
Рет қаралды 288 М.
How Steam Traps Work
7:02
MEP Academy
Рет қаралды 95 М.
Dad gives best memory keeper
01:00
Justin Flom
Рет қаралды 21 МЛН
Bend The Impossible Bar Win $1,000
00:57
Stokes Twins
Рет қаралды 45 МЛН
The REAL Problem with Smart Meters
20:05
RECESSIM
Рет қаралды 403 М.
Weil-McLain CGI Install
6:26
JP Heating & Cooling, LLC.
Рет қаралды 29 М.
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,1 МЛН
Turning Grass into Gasoline: Green Fuel Revolution
17:31
Curiosity Stream
Рет қаралды 1 МЛН
How to Flush a Water Heater? | Flushing Will Probably Not Fix Your Problem
8:06
Smart Meter Disaster!!
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 361 М.
Dunkirk DXL 82% Gas Boiler Installation
13:40
JP Heating & Cooling, LLC.
Рет қаралды 2,1 М.
Carrier BWB Boiler Spark Ignition Repair/Update
5:23
JP Heating & Cooling, LLC.
Рет қаралды 801