we use antifoam with silicon based in amine system,. Please tell me If it possible excessive antifoam (silicon based) can be precursor fouling problem at plate frame exchanger? Or the compound react with Fe to precipitate in our amine system?
@fernandolopes87432 ай бұрын
Could you indicate a good demulsifier?
@wavada872 ай бұрын
A view on caustic verse ammonia addition on the quench tower would be great!
@wavada872 ай бұрын
Great coverage of an emerging topic!
@wavada872 ай бұрын
Great review of the topic
@wavada872 ай бұрын
Great video!
@shiji19804 ай бұрын
Any need that design pressure of claus unit to be designed for deflagration? Since, the air is limited. Any incidents from your past experiences to share if we don't design for?
@MuhammadRaza-qc5nn6 ай бұрын
Love the way u explain
@MuhammadRaza-qc5nn6 ай бұрын
Good job
@MuhammadRaza-qc5nn6 ай бұрын
Good job
@MuhammadRaza-qc5nn6 ай бұрын
Awesome content
@tomaslehm40887 ай бұрын
Very happy to see this type of content in the platform. The video was pretty useful, thank you man!
@andrimaulana62627 ай бұрын
Can I apply a job in ur company?
@MuhammadRaza-qc5nn7 ай бұрын
Awesome content
@MattBower-qk2rj8 ай бұрын
Excellent 2 part video package, I love the energy! Something you may find interesting and may lead to an increase in HSAS cases.... We (Qa3) have observed oxygen being introduced into gas processes via flare gas recovery (FGR) systems. FGR systems are reintroducing gas from low pressure systems, which was histroically sent to flare, back into the gas process. A major proportion of this gas will be blanket gas (nitrogen) which is typically generated offshore from the air using membrane technology. This technology is not removing all the oxygen and hence oxygen is now being introduced into the gas process; therefore, amine units may now begin to see increased concentrations of oxygen! And a second thought on this. You mention surge drums could potentially suck air back into the process (introducing oxygen) if a blanket gas is not used. Bang on, but worth considering that the blanket gas may also contain potentially 1-2% oxygen. Another potentail source of oxygen ingress into amine units. Thanks again guys, check us out if you want to chat through our above thoughts. (www.qa3.co.uk)
@aymenmani79449 ай бұрын
Thank you for this valuable content! But sir can you please cover the part of the cracks root cause in reboilers! thank u or if you have any useful documents! thanks in advance
@adamsabdulshakur25579 ай бұрын
Please I need your help. I work in a refinery and our Gas con unit has LPG amine absorber and the LPG is all liquid. Won't there be forming or how does these design works
@sabersmira29869 ай бұрын
thank you :=)
@tunisiano323610 ай бұрын
very interesting, please correct the slide shown at 12.20 from contaminated Amine to cont Hydro
@duynatrile886711 ай бұрын
Dear Sir, can you give us the minimum value of lean amine loading, that we can monitor lean amine loading higher that can form a Pyrrhotite film layer ?? how much [H2S] in lean amine is enough. ?
@garawaful11 ай бұрын
Thanks for nice explanations. Whether COS gets converted to sulphur in TGTU reactor?
@venkysaran Жыл бұрын
@Ben, do we have expertise in CO2 dehydration using TEG solvent and material selection by analysing corrosion mechanism.
@عبدالحفيظمهدي-ذ3خ Жыл бұрын
Hi, is there any chance to get heat stable salts in SELEXOL
@augustonehme6910 Жыл бұрын
Hi! Why you dont put DEA for CO2 removal as a common case?? Thanks
@abirbasu4073 Жыл бұрын
Good information Ben. I attended some of your F2F courses as a part of Amine Experts training at McMahon plant in norther British Columbia (Fort St John). During the 3 year turnaround we used to clean the garbage out of the flash tank. Need to be careful about the present of iron sulfide while cleaning any part of the amine network. Based on my experience, residence time can be difficult to specify, but 25-30 min is reasonably good depending upon the quality of the incoming HC gas. More the better if there are some free HC liquid coming with the gas, but the design concept varies. Best practice - clean the sludge during the turnaround. Thanks for the table of residence time vs HC particle size.
@anilkp1032 Жыл бұрын
Hi, very nice info. We have a concern in sru train Sulfur storage tank. We dont have drain option to empty out and drain completely during T&I. We have to pump out using sulfur transfer pump to the bottom most of the level to main sulfur storage tank .our project team belives it can be done smoothly using pump to empty out tank completly.is our understanding corect.that it can be done smoothly. What kind of safety concerns might arise if empty out completly using transfer pump...
@bradleyt.bjerken1242 Жыл бұрын
Do you have a flow rate for hot oil reboilers? Our hot oil operates at 177 deg. C
@benspooner8690 Жыл бұрын
Brad, no there is no '"generic" recommendation for a ratio of hot oil to amine, as it depends on the heat capacity of the oil, as well as temperature. In these cases we recommend first the hot oil to about 180C (which you've already done) then increase oil flow until the desired regenerator overhead temperature is reached. Double check the temperature by checking the reflux - to - amine ratio, and check the lean loading. If those three parameters look good, make note of the oil:amine ratio and put that up in the control room. Alternatively, if you have the unit modelled on ProMax you can enter the exact type of hot oil and it will accurately predict the required flow.
@Bharateey1981 Жыл бұрын
So informative! Query: Gas injector wells near choke valve always see sulfur deposition downstream of choke valves. Gas has acid gases such as H2S, CO2 etc. Similar deposition also seen with Dry Gas Seal for gas compression system as well. Any way we can prevent it? Thanks.
@M.ChadikAnis Жыл бұрын
if the HSAS content increases, it will cause the Hydrocarbon in CO2 Venting to also increase. My question is whether HSAS can cause an increase in the solubility of Hydrocarbons in amine solutions?
@jokonurulfatoni8244 Жыл бұрын
Can high HSAS cause loss of Hydro carbon in the vents?
@akm_maut_yt4701 Жыл бұрын
Me sattar from Pakistan. I must say excellent videos that I was searching for. I am working at the amine plant where we are facing frequent reboiler tubes failure. The second is blackish TEG colour. Plant is designed 100 MM with stream 24%CO2 and 20PPm h2s.which video is for TEG.regards.
@historyclasses104 Жыл бұрын
Excellent
@schneider1028 Жыл бұрын
Hi Ben, in our stripping tower we have a huge problem due to flooding and this issue starts sometimes in the middle or in the bottom, what could be the root cause of this? In addition, the amine looks very well (clear and a very pale green) inside the tower's bottom. However, we took a sample from the reboiler feed ( is a once-through reboiler) and in that point the amine looks green cloudy.
@MS-be9wv Жыл бұрын
Is the reflux flow rate from stripper reflux drum is optimum? It is mainly water, and could cause a lot of steam vaporising in case of excessive reflux flow rate
@beautifulbirds455 Жыл бұрын
kindly upload more videos related to gas processing and equipments
@KB-ok5ob Жыл бұрын
Ty! I’m a student (ChemE). I’ve been watching your series to get some industry info. Very informative
@alexandermartinezcarvajal6364 Жыл бұрын
Que buen video.
@7375Francis Жыл бұрын
What is max allowable HSAS?
@7375Francis Жыл бұрын
More useful information But if we go with fouling resistant trays, we face debris coming to the bottom and fouling reboiler and feed bottom exchangers. Any modification suggested in tray bottom to collect these debris
@robertanand771 Жыл бұрын
Could you please talk about the liquid sulphur volume expansion and associated line rupture?
@fandikhalil7132 жыл бұрын
good evening, i need ur experience in this field about sulfur handling and crushing sulfur , we have crushing sulfur operation inside gas plant we use heavy equipment's to crushing and loading sulfur , during crushing activity there is fine dust collecting inside the engine of equipment's spicily the dozer how we can prevent the catch fire or explosion during the crushing activity , is this operation save using dozer for crushing sulfur .
@arkapravobandyopadhyay98512 жыл бұрын
Keep these coming. Hugely informative.
@arkapravobandyopadhyay98512 жыл бұрын
Please keep these videos coming.
@arkapravobandyopadhyay98512 жыл бұрын
Look forward to more videos. Keep them coming.
@manuelmiranda81262 жыл бұрын
Excellent explaination!
@syazwansharani89072 жыл бұрын
where can I see part 2
@sulphurexpertsinc77552 жыл бұрын
Hello! Part two was posted right after this video. Please find it on our channel! Thank you!
@abs1112 жыл бұрын
Thank you very much for very nice explanation
@abs1112 жыл бұрын
thank you very much for excellent explanation..
@abs1112 жыл бұрын
Very nice topic... excellent explain..thanks
@harshokareem2 жыл бұрын
Ben, good explanation unfortunately i haven't work in Amin unit but Iam working in merox unit to produce jet fuel we are using Air and caustic in our process to remove TAN but sometime foam is forming still i dont know source of this foam how it is formed regarding to your tutorial video u mention it is because of some contaminates so plz can u specify contaminates compositions to be more clear to me