Sir thank you very much very informative video and please tell me whole dc drive circuit diagram
@AshrafKhan-dg3tv5 жыл бұрын
sir good work and nice video thanks
@aforautomation5 жыл бұрын
thanks for your comment
@syedhassanali933010 күн бұрын
Sir,please tell me further more about this circuit thank you very much
@42099814137415 жыл бұрын
Nice video
@ZahidHussain-wk1zl5 жыл бұрын
Well explained bhai... Humari comapany me . . seimens ki simovert dc drive h...jo ke 720 kw ko rotate krti h... Please explain what is master slave drive...
@aforautomation5 жыл бұрын
kzbin.info/www/bejne/lZ7Xc6qcmNeoY7s this video is about master slave please watch it.then we will discuss further
@kaatnikaatni90124 жыл бұрын
Sir a question. What is FL1 and FL2 on DC drive?
@aforautomation4 жыл бұрын
It may be Field 1 and Field 2, What is model number of drive? you should look into user manual
@kaatnikaatni90124 жыл бұрын
@@aforautomation it's Parker 512C
@aforautomation4 жыл бұрын
Its Field rectifier supply terminals
@kaatnikaatni90124 жыл бұрын
@@aforautomation thanks sir, do two live wires go in FL1 and FL2 or is it Live and a Neutral. Drawings are not clear.
@aforautomation4 жыл бұрын
Not necessary its internally connected with mains supply.it you want external field supply then thease terminal are need to be connect with supply otherwise they are left unconnected
@vikramkaushik17675 жыл бұрын
hi sir Sir please make a video regarding various communications between plc to pc and vice versa with their Advantage and disadvantage for eg RS 232, , RS485, DHRIO, Control net, Profibus, USB TO ppi, Controlnet, Ethernet etc
@aforautomation5 жыл бұрын
sure. it will take some time but i will make video.
@DharmendraSingh-zm3wh3 жыл бұрын
Dcs 800 drive me kon kon se cards hote hain aur unka Kya kaam hain
@Surinder_dhanota4 жыл бұрын
Sir, pl. Make a vedio for armature and field tuning
@shashankkumar77704 жыл бұрын
Sir please make videos on cud card of simorega 6RA70 drive.
@shashankkumar77704 жыл бұрын
Videos on DC drive parameter ,communication
@DineshYadav-jo1ux3 жыл бұрын
Sir, pl. Make a video on siemens simoreg kc dc drive 825kw
@Lopanfernando5 жыл бұрын
Thanks sir..
@shailendrayadav2809Ай бұрын
Parker 590+ dc drive video sir
@otomasyonplc17754 жыл бұрын
IS IT POSSIBLE TO ATTACH THE LOGIC CODE ? HOW DO I CONTROL EXACTLY WHAT SHOULD I PULL OR OPEN THE DC MOTOR CONTACTOR
@nandjiprasad71093 жыл бұрын
Dear sir, plz describe EEI DC drive of zemco.
@SaifulIslam-fd1wg9 ай бұрын
A Dc motor arm vot 470 and ext volt 310, 60hz if we apply in input of dc drive arm volt 400 and 310 ext, 50 hz what will happen? please let me know
@aforautomation9 ай бұрын
You have to set Input power frequency in drive parameter, drive measures frequency by itself and it will generate fault if set 50 Hz and apply 60Hz.
@aforautomation9 ай бұрын
Based on Input power frequency the SCR switching time and ramp generation signal is changed
@tamonashghosh11004 жыл бұрын
Sir d.c drive programming k opar ak video baneye
@sumitkumar-rz8jk4 жыл бұрын
Sir kirloskar DC drive besic fault ke solution ke uper video banaye
@shahidakhtar97564 жыл бұрын
Hi Sir Dc motor k field current ok hai but Armature k voltage nahi aa rahe hai drive contactor on kara de rah i hai but motor chal nahi rahi hai... Main Sprint ki SL50 drive use kar raha hoon.... Sir please help kar denge problem kaha se ho rahi hai Thank you
@aforautomation4 жыл бұрын
Check power supply card, gate fuses and mains input fuses.all digital input should be healthy like fan feedback ,motor blower feedback,brake open feedback if used, if there is any fault on drive display tell me fault code.
@shahidakhtar97564 жыл бұрын
A For Automation sir maine sare fuses check kar liye hai sabhi normal hai motor blower feedback bhi aa rahi hai or koi fault bhi display nahi ho rahi hai
@aforautomation4 жыл бұрын
plc se kuch speed reference mil raha hai kya wo check karo,agar potentiometer laga hai to usko change karke dekho.
@nitinmaind89675 жыл бұрын
Sir DC 6ra80 ka optimization kaise lete hai
@yogeshtechnology24863 жыл бұрын
Sir is drive me motor on hone ke kuch der baad motor ki speed dhire dhire kum hote hote band ho jata hai kya karan hoga
@aforautomation3 жыл бұрын
check that start command input is proper and all interlock are working properly
@TajinderSingh-ft8el5 жыл бұрын
sir four quadrant regeneration and DBR selection k baare mai batayie ga
@aforautomation5 жыл бұрын
jarur.. thanks
@ajaykumarpandey25245 жыл бұрын
Abb Dc Drive ka poora power Diagram banave sir aur usko poora samjhaye
@aforautomation5 жыл бұрын
sure brother keep watching. thanks for your comment.
@Kumarraj-qf9ox3 жыл бұрын
Need you mo.no
@Kumarraj-qf9ox3 жыл бұрын
My no.9826687537
@SameerKhan-qx7ur5 жыл бұрын
Sir interlocking k upper ek or videos bnao
@aforautomation5 жыл бұрын
sure I will make.. thanks
@manishsharma-fp7bj5 жыл бұрын
Sir I want to learn dc drive and ac drive commissiong please guide me
@aforautomation5 жыл бұрын
Commissioning process is always written in user manual of VFD read everything carefully and watch maximum videos ,you will become expert one day.
@Kitty_minnie1211 ай бұрын
Multispan d.c.draiv ke canection batane ki kripa kare
@aforautomation10 ай бұрын
Plz share model number or catalog number of drive
@ajaykumarpandey25245 жыл бұрын
DC drive me line chock ka kyaa kaam hai,sir ye bhi batave
@aforautomation5 жыл бұрын
sorry for late reply. Convertors cause short-duration short circuits at their AC input so called commutation notches. to counter this we use input choke.
@nitinmaind89675 жыл бұрын
Armature voltage and current variation with field vtg and curt variation is more why??
@aforautomation5 жыл бұрын
because drive keep regulating the armature voltage as per speed and torque required and keeps field current constant.by varing the armature voltage it is easy to regulate the torque and speed.if we control the speed with armature voltage torque remains constant but if regulate the speed by field current torque drops.