Thank you sir. valuable information Nice explanation
@VKTomar-nz6ju4 жыл бұрын
Nice explained
@kaatnikaatni90125 жыл бұрын
Thanks for this tutorial
@akashtabla2 жыл бұрын
nice thank you.
@muhdsalman43869 ай бұрын
Dc shunt compound ke बारे में भी वीडियो बनाओ
@kumarsp8109 Жыл бұрын
Sir Make a video series shunt and compund speed control method
@sufisuraj5 жыл бұрын
Dear sir thanks for great video. Please make video of dc motor armature control and parameters
@aforautomation5 жыл бұрын
Thanks for watching.i will continue DC drive video series keep in touch
@dayanandagasagi8476 Жыл бұрын
Please explen how to work DC drive & plc in centrifugal machin in sugar plant,
@ملكةزماني-ذ4ر4 жыл бұрын
Doctor, would you please answer my question Please Dr Quiz week8 Find the value of Vo/Vd for the discontinuous mode of conduction for a Buck converter
@SanskaariLadka074 жыл бұрын
Sir agar field ko 50 percent me hi weak kare to kya hoga
@aforautomation4 жыл бұрын
Max speed will not achieve
@sonusinghyo2 жыл бұрын
Sir shunt motor field weakening make vidio
@rakibtechzone174 Жыл бұрын
Hello sir i need your help please My dc drive model etd 791 Isme Field Error show kar rahahe I need your suggestion please sir
@aforautomation Жыл бұрын
Please check Mains Input fuse, field power fuse if present, field winding resistance and megger,field power cable..
@rakibtechzone174 Жыл бұрын
@@aforautomation field coil resistance 8 ohm Fuse sab oky he Cabel change karke dekha But nehi horaha he
@aforautomation Жыл бұрын
@@rakibtechzone174 replace field card
@aforautomation Жыл бұрын
If problem still there replace CPU or motherboard
@kaatnikaatni90125 жыл бұрын
Sir how can we measure mili Amp in plc? We are not sure if we are getting output out of PLC.
@aforautomation5 жыл бұрын
1)Set multimeter at DC mA 2)Open one wire of mA where you want to measure 3) Connect multimeter's 1 laed in wire you removed and 2lead at that place from where you removed the wire.
@aforautomation5 жыл бұрын
multimeter should be connected in series
@kaatnikaatni90125 жыл бұрын
@@aforautomation ok thanks sir
@sagarjain44004 жыл бұрын
Dear sir In dc drive we have to set Field control mode it can be voltage control and current control so can you explain on which basis we can select this modes and what will happen by selecting field voltage control and field current control modes.
@aforautomation4 жыл бұрын
Field current is reduced to increase the motor speed above base speed this is called "Constant HP" when we need high speed and lower torque then field current is decreased upto minimum field current written on motor name plate in separately exited DC motors.
@aforautomation4 жыл бұрын
where dual speed motors are used for winder /unwinder like applications this method is used.
@parveensinghania88094 жыл бұрын
Sr how to tune field and armature of the motor with the ABB DCS800 plss explain
@bch27802 жыл бұрын
Use Wizard auto tuning, by use panel control or PC tool drive windows
@neerajkumarsingh9095 жыл бұрын
Sir IGBT , thirster or diode is tinwo mai kya difference hai is per video banye
@aforautomation5 жыл бұрын
sure.i will saperate video on every topic
@malayraj26173 жыл бұрын
Vedio me apne field voltage ke bare me nhi bataya plz explain field voltage
@aforautomation3 жыл бұрын
Field voltage is always varied to achieve required field current.
@nitinmaind89675 жыл бұрын
Sir I want AC motor field weakening ,what can I do ??
@aforautomation5 жыл бұрын
i will make video very soon.. thanks for watching keep in touch..