Пікірлер
@afsalameen3663
@afsalameen3663 Күн бұрын
Cooling of liner by compressed air in dilution zone will cause exhaust temperature coming down
@ramanathansubramanian2200
@ramanathansubramanian2200 3 күн бұрын
Any videos on blow off system of air compressor of GT
@powerplantguru007
@powerplantguru007 Күн бұрын
It's in queue
@aungmyatthein6989
@aungmyatthein6989 6 күн бұрын
မအေလိုး ကုလား
@mustafaharford6393
@mustafaharford6393 9 күн бұрын
Very technical and informative explanation, do you have any docs related to SGT-800 ?
@powerplantguru007
@powerplantguru007 7 күн бұрын
Sorry I don't have. You can find that on telegram
@Ankit_Tarpara
@Ankit_Tarpara 9 күн бұрын
Thank you very much sir for creating Gas turbine performance monitoring video... It will be very useful.
@Ankit_Tarpara
@Ankit_Tarpara 9 күн бұрын
Sir very good information regarding spread & swirl angle.. Also I want to share one learning.. After any major outage- needs to ensure liquid fuel tubing connected to same nozzle an intended otherwise swirl chart will misguide during high spread analysis. Thank you sir for very basic operational troubleshooting related video..
@samiUllah-u5l5s
@samiUllah-u5l5s 12 күн бұрын
Whether pump is a part of turbine or not.please answer
@alakhsrivastava5049
@alakhsrivastava5049 11 күн бұрын
AOP, EOP & AHP are motor driven pumps as a part turbine. And associated shaft driven pumps. Rest pumps are off base and not part of the turbine. Another motor driven pump is JOP which is used during start up and shutdown.
@mep-global
@mep-global 23 күн бұрын
Hi., It was a good explanation. Would you be able to help us on the Purafil Air filtration system with the controls for the turbines and the details of its facilitators or service providers?
@powerplantguru007
@powerplantguru007 21 күн бұрын
Okay Sure
@KhalidMehmood-js2kv
@KhalidMehmood-js2kv 25 күн бұрын
Agar aap sub lecture Urdu main B dian too sub k liayia acha ho ga
@abdalhadihusham4457
@abdalhadihusham4457 26 күн бұрын
very helpful 🙏
@powerplantguru007
@powerplantguru007 25 күн бұрын
Thank you
@adarshprakashmall8348
@adarshprakashmall8348 26 күн бұрын
Excellent sir
@powerplantguru007
@powerplantguru007 25 күн бұрын
Thank you
@zeeshanhaider9624
@zeeshanhaider9624 Ай бұрын
sir plz make video on gas turbine compartment & its components also tell about reverse type can/combusters
@powerplantguru007
@powerplantguru007 25 күн бұрын
Sure
@dhilanmahrizal289
@dhilanmahrizal289 Ай бұрын
How to setting axial play rotor correctly? 1/2 total play - thermal expansion?
@thomasmathew4469
@thomasmathew4469 Ай бұрын
No words to thank you sir, We are new and was struggling to understand these concepts. Thanks to you for making it clear.
@powerplantguru007
@powerplantguru007 25 күн бұрын
I’m glad it was helpful!
@NimeshKherala
@NimeshKherala Ай бұрын
Informative video sir…👍👌 Make One video regarding how to read MARK VIe logic diagram…thank you👍
@powerplantguru007
@powerplantguru007 Ай бұрын
Thanks for the feedback, I will try to make a video on that.
@HD-lr6td
@HD-lr6td Ай бұрын
Sir, Few days I am watching your video from Bangladesh. Recently, I started a job in a combined-cycle power plant. Is there any way to contact you?
@adarshprakashmall8348
@adarshprakashmall8348 Ай бұрын
How to reduce GT heat rate? Kindly make a video.
@powerplantguru007
@powerplantguru007 Ай бұрын
Thank you for watching my videos. I have created one you can check in playlist and there are some more to be created
@AyushDimri-v5u
@AyushDimri-v5u Ай бұрын
Sir can you please share me your number i have some enquiry
@powerplantguru007
@powerplantguru007 Ай бұрын
Hi Ayush We can have a discussion based on what questions you have. Please list your questions and we can connect, the session will be a paid session.
@GaryLee-j2v
@GaryLee-j2v 2 ай бұрын
Young Anna Johnson Melissa Jones Christopher
@powerplantguru007
@powerplantguru007 Ай бұрын
Hi Thank you for watching my videos. Do you want to tag these PPL here
@vighnarajsarang2279
@vighnarajsarang2279 2 ай бұрын
we can use also all parameters in SI units, without 860 constant
@powerplantguru007
@powerplantguru007 2 ай бұрын
Hi. yes you can very well use that.
@hunt2727
@hunt2727 2 ай бұрын
Good vid, but,, could you speak a little more clear, a bit better, please? It´s difficult to understand the sentences! Could you speak a little more didactically? Also the sound is very bad. Sound rises and descends continously! All with that, thanks so much!! You are great!!
@powerplantguru007
@powerplantguru007 2 ай бұрын
Hey thank you for watching my videos. Also i appreciate the candid feedback, I will definitely try to improve. My major viewers are from the south asia region and generally don't get such feedback.
@hunt2727
@hunt2727 Ай бұрын
@@powerplantguru007 if the understanding of words and sound become better, your vids would be unbeatable! Thanks so much!! :))
@laluprasadbehera7965
@laluprasadbehera7965 2 ай бұрын
Sir app jo gas compressor ka banaye he konsi company ka he kya iska capacity he iska sir ek details video banaye sir kindly.
@powerplantguru007
@powerplantguru007 2 ай бұрын
Thank you for watching my videos. I will create content for that
@Ankit_Tarpara
@Ankit_Tarpara 2 ай бұрын
Thank you sir for sharing valuable knowledge with us 👍🙏🏻
@powerplantguru007
@powerplantguru007 2 ай бұрын
Thank you for your kind words
@SanjayEducation-b4i
@SanjayEducation-b4i 2 ай бұрын
Thank you sir..
@jeysenfinggo270
@jeysenfinggo270 2 ай бұрын
Are these all applicable to all types of GT? I'm working now with MS9001e
@powerplantguru007
@powerplantguru007 2 ай бұрын
Thanks for watching my videos, Yes it is a fundamental thing across all gas turbines
@jeysenfinggo270
@jeysenfinggo270 2 ай бұрын
@@powerplantguru007 can you make videos also regarding surging and stall of GT or any troubles occur during start up/shutdown of GT.
@powerplantguru007
@powerplantguru007 2 ай бұрын
There are many videos i have created, please watch those.
@powerplantguru007
@powerplantguru007 2 ай бұрын
We will try to cover as many as possible
@jeysenfinggo270
@jeysenfinggo270 2 ай бұрын
@@powerplantguru007 im currently watching those videos now as i am studying for my new role. And it helps me a lot. But the start up diagram gives me a hard time to understand 😂. I'm trying to connect that diagram you've shown in the video to my source diagram here. And i found it quite different especially you said from start command RPM will increase as well as doing purging. Here in my job site we need to take it to 700rpm and then do purging for 5mins. So i'm a bit confuse.
@alfredomartinez6645
@alfredomartinez6645 2 ай бұрын
Hi! I think it would be interesting to analyze a graph including humidity!
@powerplantguru007
@powerplantguru007 2 ай бұрын
Hi thank you for watching my videos, yes we can do that. Let me cover individually first and then we can collate one or two
@abhishekkumarupadhyay1385
@abhishekkumarupadhyay1385 2 ай бұрын
Sir aap hindi me v vdo banaya kijye
@powerplantguru007
@powerplantguru007 2 ай бұрын
Thanks for watching my videos. I tried in hindi but those were not getting popular.
@MANOHAR_GADDALA
@MANOHAR_GADDALA 2 ай бұрын
Hii sir can u make a video on LCI and Excitation how it works in gas turbine
@powerplantguru007
@powerplantguru007 2 ай бұрын
Will try
@Lev-Heart
@Lev-Heart 2 ай бұрын
You made this topic easy to understand. Thank you
@powerplantguru007
@powerplantguru007 2 ай бұрын
Glad it was helpful!
@rohitdixit-9483
@rohitdixit-9483 2 ай бұрын
Sir video not see
@powerplantguru007
@powerplantguru007 2 ай бұрын
Cannot understand your comment
@rohitdixit-9483
@rohitdixit-9483 2 ай бұрын
@@powerplantguru007 pictures are not visible in this video
@ashwinnarayan4450
@ashwinnarayan4450 3 ай бұрын
what is FSR GAGGING?
@powerplantguru007
@powerplantguru007 3 ай бұрын
FSG gag function is preliminary used for troubleshooting MW hunting issue. When machine is normal- SRV/GCV, MW & fuel flow is constant but if hunting starts- all parameters will oscillates- so to identify that fluctuation is due to which issue? FSR gag is useful. When FSR gag- GCV will maintain same CV opening and if load fluctuations stops- seems problem with GCV servo or related loop. If still problem persists need to look into SRV, MW transducer, fuel circuit etc.
@akashkarn8393
@akashkarn8393 3 ай бұрын
Hi Sir, How to join your classes?
@powerplantguru007
@powerplantguru007 3 ай бұрын
Hi thank you for watching our videos. You can click on the join button to get our membership. Then you can know when sessions are happening and you can ask relevant questions.
@Ankit_Tarpara
@Ankit_Tarpara 3 ай бұрын
Thank you sir for very critical information about Gas turbine inlet air system..👍
@powerplantguru007
@powerplantguru007 3 ай бұрын
Thank you for your kind words
@somnathjana7474
@somnathjana7474 3 ай бұрын
How filter can self cleaned...
@powerplantguru007
@powerplantguru007 3 ай бұрын
APU is the unit which works for self cleaning. The air pressure from APU comes in opposite direction of normal flow and push the dust accumulation
@powerplantguru007
@powerplantguru007 3 ай бұрын
This will reduce the filter ageing
@somnathjana7474
@somnathjana7474 3 ай бұрын
@@powerplantguru007 How the opposite direction of normal flow can work..
@powerplantguru007
@powerplantguru007 3 ай бұрын
The normal path from the air filter is outside to inside where atmospheric air is filtered and dust accumulation is on filter happen, in self cleaning cycle there is a solenoid operated compressed air supply is placed inside, once inside valve open cleaning is done
@somnathjana7474
@somnathjana7474 3 ай бұрын
@@powerplantguru007 Thanks for explanation..
@soudeepsaha675
@soudeepsaha675 3 ай бұрын
Can you explain the hydraulic servo motor control system of the IGV piston with accumulators and trip solenoid?
@powerplantguru007
@powerplantguru007 3 ай бұрын
Sure
@robertpotter4700
@robertpotter4700 3 ай бұрын
Can you explain what a packing tooth scraper is used for? Is it used on the glands/labyrinth seals or is there packaging material that is being scraped out of the glands/seals?
@Ankit_Tarpara
@Ankit_Tarpara 3 ай бұрын
Thank you very much sir. If is very useful concept for operating boiler and understand operating parameters in case of emergency..
@ardaomeryavas3600
@ardaomeryavas3600 3 ай бұрын
Makes the nuclear power plant run twice the fps lol
@rajazain2872
@rajazain2872 3 ай бұрын
Why operater have low water level before boiler light up kindly sir tell me
@powerplantguru007
@powerplantguru007 3 ай бұрын
Hello thanks for watching my videos. As you start the boiler the water temperature rise and accordingly volume will rise and the level will increase. That's why the boiler started with a little lower level than the normal level .
@HamadKhan-ol5pu
@HamadKhan-ol5pu 3 ай бұрын
Could you please help me with mechanical QC engineer interview at Air filters manufacturing company? It's urgent please email me or comment it here. Thanks
@mahmoudmoqbal7239
@mahmoudmoqbal7239 3 ай бұрын
I have one doubt regarding to the steam turbine ST-up which one to be first creat vacum or gland steam.
@powerplantguru007
@powerplantguru007 3 ай бұрын
Hello Thanks for watching our channel. The vacuum pulling is the first step. For more details you can join our live Q & A session.
@mahmoudmoqbal7239
@mahmoudmoqbal7239 3 ай бұрын
@@powerplantguru007 thank you for your respons when it will be.
@powerplantguru007
@powerplantguru007 3 ай бұрын
We do it on Sunday, and it's a paid session. You can send your quotation and the experienced experts will be there for explaining and teaching
@riteshkumarverma2397
@riteshkumarverma2397 3 ай бұрын
Sir when your next webinar sheduled?? I'm not getting any mail regarding webinar
@powerplantguru007
@powerplantguru007 3 ай бұрын
Hello Ritesh, thanks for your interest. The webinar information is being shared with channel members only. If you wish to join, please join the channel membership.
@mrbrown2065
@mrbrown2065 3 ай бұрын
Engineer says all posdible / could, but at what price especially the battery storage. Ideas not pracctical
@powerplantguru007
@powerplantguru007 3 ай бұрын
Hello You are right 👍..but imagine how solar PV was 10-15 years ago and how it is now. May be battery storage will not be scaled but pumped storage or some other tech will dominate the market.
@mik2137
@mik2137 10 күн бұрын
You have no clue, BESS are getting cheap as fuck. Forget new pumped hydro storage, its getting substituted by BESS.
@sundaramnarayanan1375
@sundaramnarayanan1375 3 ай бұрын
you are confusing.... make it clear,, swelling and shrinking
@powerplantguru007
@powerplantguru007 3 ай бұрын
I have created another video on this topic
@Ajay-wi8nd
@Ajay-wi8nd 4 ай бұрын
As per my experience about Graphenizer-4 oil (made with Graphene) can take the Turbine lube oil system to next level for sure. a.) It forms a micro-film coat layer of Graphene like a shield inside that controls friction, wear & tear and protects from other negative factors. b.) It Increases efficiency on metal-to-metal surfaces & other internal moving parts. c.) It reduces the Over-heat up to 60% and extends the life span. d.) It also reduces the load drastically. e.) It turns the excessive noise / sound into smooth running. For more info search in google for Graphenizer-4.
@umarjune1994
@umarjune1994 4 ай бұрын
Thanks alot please make video Air processing unit (APU) OF gas turbine
@powerplantguru007
@powerplantguru007 4 ай бұрын
We will try
@basili5238
@basili5238 4 ай бұрын
Great Summary!! Thank you
@hasan5658
@hasan5658 4 ай бұрын
Thanks for the excellent explanation. However, the pointer is not visible, which can sometimes make it difficult to understand.
@hasan5658
@hasan5658 4 ай бұрын
thanks for this nice explanation. Where is the next part?
@Ankit_Tarpara
@Ankit_Tarpara 4 ай бұрын
Thank you very much sir for sharing your knowledge on very basic concepts of power plant.. 👍