Healthy Climate Filter Cabinets
3:56
Partnerships for Success
3:37
9 ай бұрын
Introducing The EL297V Gas Furnace
4:43
MMA High Efficiency Air Handler
2:30
Enabling Advanced Diagnostics
1:56
How To Connect To Wifi
1:20
Жыл бұрын
The Smart Air Quality Monitor
2:37
Can I paint the Wireless Extender
0:13
Sleep Mode
1:44
Жыл бұрын
Пікірлер
@canyoncruzr3462
@canyoncruzr3462 6 сағат бұрын
Avoid Lennox evaporator coils. They fail prematurely. Cost me $thousands.
@techmelissa
@techmelissa Күн бұрын
Does the set screw have to go onto any particular place on the shaft? I noticed the shaft have groves in it on the flat part. Does the set screw need to line up with these groves on the flat side of the shaft? I noticed the set screw fits in the groves so that’s what makes me think that’s where it goes on the shaft.
@j.p.8276
@j.p.8276 8 күн бұрын
Why don't they make quick disconnect fittings for HVAC lines? It would be so easy.
@j.p.8276
@j.p.8276 8 күн бұрын
You're missing the point of the question. When disconnecting, you are not only releasing pressure from the hose, most of the release is coming from the AC unit. And the higher the pressure the faster it comes out. I had a release today that I wasn't expecting because the high side pressure was close to 600 PSI. It was still 525 PSI after about a 3-4 second release that went mostly on my hand. I had some minor burns and I put on gloves right after that. I assume it was overcharged at some point because normal high side is 450 PSI. Other than screwing the fitting off quickly, is there any way to prevent such losses disconnecting?
@canuck-guy2384
@canuck-guy2384 9 күн бұрын
Has anybody removed a fan-blower from a counter flow furnace?
@awatule
@awatule 10 күн бұрын
Good job homey
@ironllama
@ironllama 10 күн бұрын
I had a older thermostat and no wifi. Service tech shorted all my boards so they installed this crap. Since then no one can figure out why in AZ i have 50% humidity in my house during summers. The unit will dehumidify sometimes and sometimes not. The thing is complicated and no lennox peo dealers can seem to figure it out
@JAWmankato
@JAWmankato 14 күн бұрын
Why doesn’t Lennox stop worrying about selling their product and concern themselves with producing a quality produxt
@db3467
@db3467 15 күн бұрын
They went from 96 to 97 per cent
@toloulafaumuina3068
@toloulafaumuina3068 18 күн бұрын
Great video helpful
@JuanMartinez-df1lc
@JuanMartinez-df1lc 18 күн бұрын
Damn I don’t think I have the coordination to do that
@eyayouestifanos9746
@eyayouestifanos9746 20 күн бұрын
Thank you sir
@UtubeAdviser
@UtubeAdviser 24 күн бұрын
wout it work if i wanted to use it on the 3/8 that's attach to the copper line that goes from the inside unit and goes all the way outside the house? That hose is only 3/8 and is like plastic or vinyl and it attached to a skinnier copper line. Would the tip of that gun work there?
@beretta0222
@beretta0222 25 күн бұрын
You are not measuring an inrush current .
@erikb5100
@erikb5100 26 күн бұрын
Firstly, for beginners like me, I always take a picture of the board/wires to ensure they're put back properly. Second, never yank off the wires; hold the board while pulling them off gently. And third, I used a coat hanger to hold the board up and away to remove the blower, much easier! ✌️😎
@framemaker52
@framemaker52 27 күн бұрын
The SS2 float switch is not shutting off the HVAC when the line is full of water. I assume the switch is bad. OK to replace the switch by cutting the small black wires going to the air handler, and connecting the new switch to those existing black wires using acorns?
@rickdavis4740
@rickdavis4740 29 күн бұрын
Turn the oxygen off 1st. If you've ever read the directions from Uniweld, it specifies turning oxygen off 1st
@cgtotty
@cgtotty Ай бұрын
Thank You, Sir ! A clear, concise, easy to understand video. Job well done !
@Brian-xu9uq
@Brian-xu9uq Ай бұрын
This is such a biased video from Lennox. So they’re measure pressure drop , aka, the resistance of the filter. A few things others have pointed out along with my observations. The study tests filters that aren’t consistent in thickness and number of pleats. Generally, the more filter media material, the lower the pressure drop. The video starts with, these filters have not been altered in any way, yet they’re cut and glued to make a smaller segment. I’m seeing some obvious extra cardboard material on the non Lennox filters 😂. We came here for a scientific tests and I was hoping they wouldn’t be so biased but that’s never the case with these big corps.
@modinorosejanec.2694
@modinorosejanec.2694 Ай бұрын
What type of tube is that?
@franciscogonzalez9565
@franciscogonzalez9565 Ай бұрын
This video is misleading, I design hvac systems with MERV 20 at PD of 0.24"wc and MERV 13 @ 0.12" wc PD. and I don't use Lennox products.
@user-xk7ge9jz4q
@user-xk7ge9jz4q Ай бұрын
Awesome, informative video!
Ай бұрын
Fantastic✔Sent this to my HVAC folks since they didn’t know how to use their clamp on meter etc. I want to run my AC on a portable generator so need the new surge amps after the soft start installation. If it’s below 30 amps, I’m good.
@jely7698
@jely7698 Ай бұрын
THANK YOU!!!
@adamsteele6148
@adamsteele6148 Ай бұрын
Now do it for a merv 5
@kdcarver
@kdcarver Ай бұрын
It may be beneficial to inform folks about the difference between a hard start kit and a soft start kit. A hard start kit actually will not change the inrush current, it will simply decrease the duration of this spike. A soft-start kit, on the other hand, should decrease that spike peak.
@swamicbz
@swamicbz Ай бұрын
My builder installed it. This is too noisy and can’t sleep
@sepehrfadaei7564
@sepehrfadaei7564 Ай бұрын
My refrigerator (Samsung RS277ACRS/XAA-0000) stopped working after a power outage. The ohm readings on the compressor are: C-S: 0.4 ohm C-R: 3.4 ohm I was wondering if such a low reading on the start winding is normal for this model. The Start Relay (thermistor, DA35-00135A) was not showing continuity (R = 1300 ohms), so I replaced it. The new one couldn't start the compressor either. When I test the new one, it also does not have continuity (R = 4000 ohms). I do no know if I got a bad start relay, or my compressor is bad, and the by pulling too much current burns the start relays. The overload protector has continuity, and seems to be fine.
@bretsheffer8263
@bretsheffer8263 Ай бұрын
So basically they hide the bug deeper in the salad. Got it.
@onnihytti
@onnihytti Ай бұрын
While the compressor is running I close the liquid shut off valve from the unit and using the pump down method I suck all refrigerant from the manifold and hoses into the system until the pressure is zero. Then I disconnect the hoses and open the liquid shut off valve again and the system keeps running. This is really a low loss method.
@jmccOutdoors
@jmccOutdoors 2 ай бұрын
It’s 2652 but hey you’re Lennox so details don’t matter 🤡
@jimjackson4256
@jimjackson4256 2 ай бұрын
It is kind of a pain that you can’t just change the motor and not the whole assembly.Why put cooking oil on the back? Wouldnt you want the silicon to stick to the surface ? Wouldnt that be more airtight than if it is not sticking?
@Foodformyboys
@Foodformyboys 2 ай бұрын
How does this torch compare with the Ambro Oxyset torch?
@WiLLiAmKaNeHVAC123
@WiLLiAmKaNeHVAC123 2 ай бұрын
I tried that once, it sparked N popped.
@gotchaplumber
@gotchaplumber 2 ай бұрын
Good points.
@Ben-fu3pd
@Ben-fu3pd 2 ай бұрын
We weed a temp lockout option, example if user bring temp to 73 and thats is set as the lockout temp it will not heat to 73 will lockout app and unable to use until homeowner puts in passcode to bypass lockout.
@phatsacz20003
@phatsacz20003 2 ай бұрын
on point video
@LeonardCooperman
@LeonardCooperman 2 ай бұрын
Is this just a 5 stage system? Like the Carrier Vs 18 ?
@donmccloud1422
@donmccloud1422 3 ай бұрын
Very close? Is 34 ohms close enough to 32 ohms for a fridge compressor to be good?
@GrayRefrigerationWorkshop
@GrayRefrigerationWorkshop 3 ай бұрын
Hi Mr Gray
@rickdavis4740
@rickdavis4740 3 ай бұрын
I use the Uniweld 71 torch handle with a Type 17-1 tip. Set my pressure at 5 psig on acetylene & 5 psig on oxygen. I have zero problems brazing up to ⅞ copper using 15% sil fos sticks. I absolutely refuse to try Stay Brite 8 on refrigeration lines!! Sil Fos has never let ne down. I will be honest... the Uniweld micro 6000 rosebud tip has certainly had me curious!! Does it really make brazing as easy as everyone seems to think?? Ive been brazing copper tubing for the past 16 years with my current setup with very minimal issues.
@user-iw4xt7ze1e
@user-iw4xt7ze1e 3 ай бұрын
comfort sync® a3 thermostat what is the difference between all your Models.
@raywalker2938
@raywalker2938 3 ай бұрын
😅You took a 410-a and added the refrigerant with the bottle upright. Now not only did you compromised the c/u--but your jug of 410A is now missing one of the refrigerant
@raywalker2938
@raywalker2938 3 ай бұрын
My bad-------- I see it's a recovery tank😂
@Kelvinbellrose
@Kelvinbellrose 3 ай бұрын
What a helpful tip
@STS4747
@STS4747 3 ай бұрын
Would you say these are better then the digital field price gauges?
@bob_818_pedos_need_to_be_shott
@bob_818_pedos_need_to_be_shott 3 ай бұрын
Thank you sir