I like the dual colour display feature. If the tested circuit parameters are OK, the display is green. If it senses faults like reverse polarity, missing earth then the display turns red. This ensures that we won't miss faulty circuits.
@kharna_feed24 күн бұрын
How much time will press the test button for reading
@30mAkills23 күн бұрын
Until reading is stable.
@bobyantony2937Ай бұрын
Gud one sir ❤
@elect874Ай бұрын
How many second rotate hadle sir
@30mAkillsАй бұрын
Refer user manual. Normally 160rpm
@elect874Ай бұрын
Sir which side input or out put...for rccb
@30mAkillsАй бұрын
According to labelled diagram
@elect874Ай бұрын
Netural earth link aanulum light eariumeay sir...?
@elect874Ай бұрын
Sir iam felix from ooty...rcd available a sir please rate and details and rccb and rcd different sir
@30mAkillsАй бұрын
RCCB and RCD are same. About rate enquire in electrical shops.
@Blathurkaran2 ай бұрын
Sir what happened when we set 10 ohms
@30mAkills2 ай бұрын
Like multi meter display will show OL if the resistance value exceeds 10 ohms.
@Blathurkaran2 ай бұрын
@@30mAkills I have get reading 01.8 is it good
@30mAkills2 ай бұрын
@@Blathurkaran what's the resistance value of lead wires? Also study FOP method from AEMC/Fluke/Megger knowledge base which are freely available at their web sites. FOP graph will be useful. Hope this helps.
@30mAkills3 ай бұрын
IR Testers or Meggers are widow-makers unless you follow the below safety precautions: 1. Always wear gloves. 2. Check the probes and leads visually for damages like cracks, frayed necks and exposed wires. 3. Ensure that the device or circuit under test is not energized. 4. After testing, discharge the residual voltage retained by the device (cables, motors and transformers due to capacitive effect) simply by grounding the device terminals for a minute.
@elect8743 ай бұрын
Meter price sir
@30mAkills3 ай бұрын
Check in amazon
@30mAkills3 ай бұрын
You can also destroy a multimeter by trying to measure volts when the probes are plugged into the amps port!
@statuztamila3533 ай бұрын
Enaku unga videos paathu learn pannikanum nu aasai iruku but language problem ah iruku🤦🏻♂️😢
@30mAkills3 ай бұрын
DUT: HTC CL 2054 Leakage current Clamp Tester. Purpose of video: Calibration of mA range. Verdict: Readings are within tolerance limits. Hence Recommended. Uses: Leakage current testers are commonly used for measuring leakage currents (differential) which are present in mA range in any electrical circuit or equipment, which cannot be sensed by normal clamp meters. At higher ranges say 1 amps and above the leakage tester can be used as normal clamp meter. Usage method for measuring leakage current: Clamp all current carrying and neutral conductor (if present) together between the jaws or only the earth wire of the circuit. Precautions: 1) The wires should be approximately at the centre of the jaws. 2) The jaws should be closed firmly without any gap. 3) Wear gloves for safety. Causes of Leakage current: Insulation failure, capacitance, filters, improper earthing, are some of the common reasons. Effects of leakage current: 1) Can cause nuisance tripping of RCCB's. 2) Fire. 3) Electrocution during monsoon. Audio Correction @ 6:39 = RCCB and not MCB
@30mAkills3 ай бұрын
DUT: HTC CL 2054 Leakage current Clamp Tester. Purpose of video: Calibration of mA range. Verdict: Readings are within tolerance limits. Hence Recommended. Uses: Leakage current testers are commonly used for measuring leakage currents (differential) which are present in mA range in any electrical circuit or equipment, which cannot be sensed by normal clamp meters. At higher ranges say 1 amps and above the leakage tester can be used as normal clamp meter. Usage method for measuring leakage current: Clamp all current carrying and neutral conductor (if present) together between the jaws or only the earth wire of the circuit. Precautions: 1) The wires should be approximately at the centre of the jaws. 2) The jaws should be closed properly without any gap. Causes of Leakage current: Insulation failure, capacitance, filters, improper earthing, are some of the common reasons. Effects of leakage current: 1) Can cause nuisance tripping of RCCB's. 2) Fire. 3) Electrocution during monsoon. Audio Correction @ 6:39 = RCCB and not MCB
@30mAkills3 ай бұрын
Don't do this if you don't have the guts😮 So we should not measure volts when the probes are plugged into the amps port. Great lesson.
@KamalSingh-qy2dd4 ай бұрын
What is E1 and P1 and E2 and P2
@statuztamila3535 ай бұрын
Sir, konjam tamil laye video podunga sir Adhum konjam shorts video within 58 sec kulla potingana views nalla pogum sir Video podringa ilanu sollala But adhu useful ah correct aana audience ku poi seranum la sir adhukkaga sonnen👍
@30mAkills5 ай бұрын
We use long reels of wires during earth pit resistance testing. The length of lead wires is based on the earthing system. For single electrodes it is 10 times the burial depth as per thumb rule. For array it is 10 times the diagonal length. Wires of such long lengths have self or inherited resistance which has to be deducted from the earth pit resistance value in order to obtain the real value. This video describes the procedure for finding the lead wires resistance value.
@30mAkills5 ай бұрын
The crocodile clips are rated CAT 111 (1000 V max and current of 10 Amps)
@30mAkills5 ай бұрын
HTC capacitance tester CM 1500/1501 pros and cons: Pros: The physical build quality assures sturdiness and long life. It has back stand and protection holster with pen holder slots. Large display. On/off button, zero set button. Smooth indented range switch. Consistence. Cons: Users want back light and hold feature. Over all verdict : Cheap and best, with wide range which covers a spectrum of users like pcb, elec and electronic, HVAC, Automotive, motor and lab techs. Also suits DIY's and hobbyists. Note: If you want a original product then buy directly from the manufacturer. P. S. In some spots I mentioned the units (milli/microfarad) incorrectly. Please excuse.
@30mAkills5 ай бұрын
Note that proper method is to use RCCB tester because both these methods (socket tester and test lamp) don't sense trip time which is crucial.
@elect8745 ай бұрын
Sir one doubt human body m.a...capacity ...
@30mAkills5 ай бұрын
About 30 mA for more than 300 millisecs.
@elect8745 ай бұрын
❤ thanks sir
@nov18ffxxx6 ай бұрын
Sir hindi me smjha do
@nov18ffxxx6 ай бұрын
Sir hindi me smjha do
@statuztamila3536 ай бұрын
Sir Neenga tamil la pesi shorts video potta nalla views and reach aagum
@30mAkills6 ай бұрын
0:11 correction: voltmeter
@30mAkills7 ай бұрын
Self/auto calibration is limited to 5 times only.
@narendrabhatia61407 ай бұрын
U HV WASTED 2 MIN TO REMOVE E CONNECTOR USE NOSE PLIER OR MALE FEMALE CONNECTOR ...
@30mAkills7 ай бұрын
You do and post it.
@30mAkills7 ай бұрын
Variacs don't like shorted loads. So before connecting a load to Variac, ensure that the load is not shorted. The input and output are not isolated like a conventional transformer. So be careful while handling. The output load side must be protected with quick blow glass fuse of appropriate rating to protect the Variac.
@rajeshpt41467 ай бұрын
What is 180 phase angle and 0 phase angle
@30mAkills7 ай бұрын
Please google Alternating current sine wave. Your doubt will get cleared.
@chabduljutt87157 ай бұрын
Time hi waste kyaa hy😢
@30mAkills7 ай бұрын
Who told you to watch?
@30mAkills7 ай бұрын
As wattage increases the amount of tungsten used is less. 18 watts uses less tungsten than 10 watts. So it's cost cutting for the company. If the real wattage is mentioned people will not buy it as they think 18 watts is too bright as night lamp.
@30mAkills7 ай бұрын
Those slots are isolation between various high-voltage and low voltage parts of the board. Air is a very good insulator whereas the surface of the PCB can become low resistance in the presence of condensation or moisture or spikes.
@elect8747 ай бұрын
Please post m ohms reding chart
@30mAkills7 ай бұрын
Please contact thru my mail id for your requirement [email protected]
@elect8747 ай бұрын
Help full sir
@30mAkills7 ай бұрын
When the air is wet be careful with water contact elec appliances like water heaters, washing machines, water pumps, wet grinders etc, as the insulation resistance of both the appliances and your body goes down and you are at greater risk when compared to normal sunny season.
@statuztamila3538 ай бұрын
தமிழ் ல கொஞ்சம் சொல்லித்தரலாமே சார்
@30mAkills8 ай бұрын
10 watts bulb label padi, aanal18 watts real consumption. Enavae 1 hour ku 8 watts adigamaga pay pannugirom. 10 hours ku 80 watts. Corporate cheating.
@zahirbasha84708 ай бұрын
Thanks for the video
@zahirbasha84708 ай бұрын
Good Information Sir
@elect8748 ай бұрын
😢
@30mAkills8 ай бұрын
Sitting on the cross arm @ "o potential " and pecking the phase line @ "240 potential" in rainy season with it's wet body at low resistance is a perfect recipe which has lead to this scenario. Sorry.
@30mAkills8 ай бұрын
A 2 pin plug or top of a metal bodied appliance is dangerous as it can be reversed into the socket. It's not foolproof. We don't know which of the two wires is connected to the appliance switch. Means non polarised. So we have to find which wire is connected to the switch and mark the corresponding pin of the plug as Phase with letter P or a red dot with marker pen. One day it will save you.
@30mAkills8 ай бұрын
Horrible eye posture due to eye problem (Retinal vein occlusion)_will improve next time.
@30mAkills8 ай бұрын
The label of the incandescent night bulb mentions the power consumption as 10 Watts, but the true consumption is 18 Watts. So the charge for 8 watts is waste for the end user. Instruments used: 1. Yokins make Y9 model wattmeter, 2.Metravi make PG-01 model Multifunction Power Guard with Energy Meter.
@user-jm4do5zu2t11 ай бұрын
Thank for your brief explanation🙏
@user-vq5by8zv8q Жыл бұрын
😮
@jeffpoole8404 Жыл бұрын
"promo sm" 🙂
@30mAkills Жыл бұрын
Please spread awareness about this mandatory govt order on RCCB's. PDF Link: www.tnerc.gov.in/PressRelease/files/PR-050120230515Eng.pdf