Single door Continental Freezer
9:11
Fun with electronics
25:16
8 жыл бұрын
Low evaporator saturation point
20:35
Soda coolers with dirty condensers
3:37
Tin knocking
16:49
8 жыл бұрын
Expansion valve replace and adjust
50:44
True Two door freezer not cold
26:49
8 жыл бұрын
JJ's Greenhouse part2
46:33
9 жыл бұрын
Compressor change on walk in cooler
36:27
Пікірлер
@ljmanz55
@ljmanz55 3 күн бұрын
Video sucks
@davidharmon8745
@davidharmon8745 Ай бұрын
E miss you.where have you been.
@sman5877
@sman5877 3 ай бұрын
wow at the dust . a vacuum cleaner hose under a bed sheet would have caught the dust.
@sman5877
@sman5877 3 ай бұрын
i’m surprised that they didn’t clean the dirt off the fan.
@freespacejunkremoval
@freespacejunkremoval 3 ай бұрын
How much would it be to just remove the original refrigerant on a unit that size.?
@matt697845
@matt697845 2 ай бұрын
What are you talking about? It already leaked out. Always.
@yasercoolyasercool1090
@yasercoolyasercool1090 3 ай бұрын
Hello Mr. Jim Pettinato why did the lessons stop for a long time I hope you are well.. Yasser
@MoodMuzikFilez
@MoodMuzikFilez 4 ай бұрын
so its not risky to close off the suction line while the unit is running ? I've always been told other wise. does it depend on type of unit?
@thanosgeorgopoulos5885
@thanosgeorgopoulos5885 5 ай бұрын
what could i do to make long harvest cycle besides hammer and screwdriver ??
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 5 ай бұрын
mineral oil would stick to chlorine poe oil floats threw the system.sum times the oil can float and get stuck on top of the refrigerant in the reciever according to emerson. the cure was adding a bit of mineral oil so it could help push the poe oil.
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 5 ай бұрын
digital controls are a weak link in the electrical system they can get damged in a short situation
@alfonsotoscano5096
@alfonsotoscano5096 5 ай бұрын
The best teacher that I could ever find. Thanks for sharing your knowledge.
@glenjones4404
@glenjones4404 6 ай бұрын
The condensing unit needs turning round 💯 as the hot air is not going to escape any where Plus its hard to work on as its been fitted backwards 🤠 Fitted by cow bows 🤯😂😂😂
@Robot-p7q
@Robot-p7q 6 ай бұрын
Why not have the fans draw the air through the coil
@abaidrehman4883
@abaidrehman4883 6 ай бұрын
So wonderful lecture thoroughly explained thank you so much.
@ilovenythismuchilovenewyor5801
@ilovenythismuchilovenewyor5801 6 ай бұрын
yea but aren't u adding air into the lines doing it like that
@RichardMarte-w6v
@RichardMarte-w6v 7 ай бұрын
You should clean the fan before you put it back together! 😮 or your helper!
@LadariusCapersOfficial
@LadariusCapersOfficial 7 ай бұрын
The coils can use a little love to 😊
@glenjones4404
@glenjones4404 7 ай бұрын
The condensing unit needs utting out side with an housing as it will always struggle up there with the heat building up
@glenjones4404
@glenjones4404 7 ай бұрын
Blocked condenser as its in a dusty environment so the condenser needs blowing out
@glenjones4404
@glenjones4404 7 ай бұрын
When you adjustment on txv you should ut the top back on as your letting alot of hot air enter which will drive it up the wall plus you could add a sight glass in the future which would make easier to diagnose next time
@glenjones4404
@glenjones4404 7 ай бұрын
Starved coil
@glenjones4404
@glenjones4404 7 ай бұрын
The compressor sounds like it screaming loke its under pressure very loud tone
@pedrojardim325
@pedrojardim325 8 ай бұрын
Hi. There Good stuff jim😊
@CRESEDA
@CRESEDA 8 ай бұрын
Thank You Sir, Excellent Video!
@DeryaTanbasi
@DeryaTanbasi 8 ай бұрын
Your the man!!!!
@williamworth2746
@williamworth2746 8 ай бұрын
Teaching your apprentice right i had wrenches thrown at me. There are allot of alcoholics in HVAC-R
@memimonimo
@memimonimo 8 ай бұрын
I need to know if this old compressor using ammonia or freon 12 or other things.
@brandoncorrea511
@brandoncorrea511 9 ай бұрын
What fan motor he used to replace?
@dhaslam003
@dhaslam003 9 ай бұрын
The system is low on refrigerant or has a plugged drier. Sight glass not supposed to flash in low ambient. It’s flashing because refrigerant is stacking in condenser to keep up head pressure and there isn’t enough liquid in receiver. Clear glass and add an extra #. That’s what I would do.
@sparkyedu
@sparkyedu 9 ай бұрын
I thought semi compressors are better why would you down grade?
@951cast
@951cast 9 ай бұрын
How are you getting the TD?
@abazism
@abazism 10 ай бұрын
Can you please tell me the what the the super heat should be for freezer and cooler ? 8-12 for freezer and 15 for cooler ?
@bigdaddy4975
@bigdaddy4975 10 ай бұрын
where is this guy now?
@robertbeckler5058
@robertbeckler5058 10 ай бұрын
Don't yah love the dull zip screws.
@tbone6354
@tbone6354 11 ай бұрын
A very helpful tip to extend the life of the compressor is to add 50ml of water to the compressor before regassing. This will cool the compressor
@uptownphotography
@uptownphotography 11 ай бұрын
I have a GE condenser motor that keeps stopping or spinning very slowly on a Kenmore older frig. Great idea as i was going to remove the metal cap to oil the bearing but I like your idea if i can find my awl. I am having trouble locating a replacement motor if you have any ideas where to buy that would be great. My motor is basically all metal design, like yours, rather then these cheap plastic replacements... Phil Jersey Shore Area
@bigdaddy4975
@bigdaddy4975 11 ай бұрын
Can anyone tell what happened to Jim all I see are 10 year old videos?
@douglasdc6516
@douglasdc6516 11 ай бұрын
I love these old Refrigeration mechanical rooms from these old mom and pop stores I’ve managed to rescue over 12 of these belt drive condensers over the years , I love them !
@reynaldolacayo6594
@reynaldolacayo6594 11 ай бұрын
señor !! what happen with you ?? are you got out of business !! i used to love you videos
@billkentli
@billkentli Жыл бұрын
Super Work. Hallo from Germany...
@winkhvac62
@winkhvac62 Жыл бұрын
Thank you Jim
@douro20
@douro20 Жыл бұрын
I wonder if Frigidaire built any belt-drive walk-in cooler refrigeration units? The A-6 swashplate compressor would had worked well for that.
@Justin-vr5zn
@Justin-vr5zn Жыл бұрын
whhhaaattt? how are you able to work without a van full of packout? did people really have to work like this back in ancient times? looks like something out of the flintstones.
@garypoplin4599
@garypoplin4599 Жыл бұрын
19:57 - Tightening a seized nut before loosening it makes it easer to remove. If you hadn’t said anything I would have thought you did it on purpose!
@garypoplin4599
@garypoplin4599 Жыл бұрын
10:26 - Just for everyone’s benefit, the dimple maker on your crimps are for bare connectors only. Insulated connectors are crimped with the oval part of your crimps (just sayin’). Thanks for sharing your work techniques.
@abazism
@abazism Жыл бұрын
Should I first clear the sight glass then adjust the txv ?
@comeonwindows7
@comeonwindows7 Жыл бұрын
hi, is this compressor an inverter technology?
@فرجالتوغار
@فرجالتوغار Жыл бұрын
شكرا
@arcticzone9223
@arcticzone9223 Жыл бұрын
Must be the reason my coil keep icing up
@ArisBuliteanu
@ArisBuliteanu Жыл бұрын
12:40