15:10 In question it was given that the Load acting on the simply supported beam is 21 kn, so the value of factor load in calculating deflection should be 31.5 by including one value of Length
@heinmt3178Ай бұрын
Why don't we use 400 N/mm2 if we want to calculate for bolt bearing strength?
@SaurabhKumar-ct9xd2 ай бұрын
Sir but here the area of base plate is greater than area of concrete padestal 157500>155555.55 Any problem?
@kierancurrie26772 ай бұрын
How do we know what e is
@muzzamilmushtaq29952 ай бұрын
Thank you sir u literally cleared all my problems
@fredthe522 ай бұрын
must be 10,5 m2 x 8,75 kN/m2 = 91,875 kN and then 91,875/5 meter = 18,375 kN/m on beam SB.👌👌👍👍
@fredthe522 ай бұрын
The answer is wrong must be 18.375 kN/m on SB
@RiyazAhmad-z3b4 ай бұрын
Thanks sir 👍
@SouvikCivil5 ай бұрын
Thanks a lot sir very useful video
@mohammedsabeel76685 ай бұрын
From which textbook u explained, I mean terminologies are from which textbook?
@saadAhmad-db5sc6 ай бұрын
what about the the segments whuch are not completely under teh strip but some of the portion is being covered ?
@bhabindrakarki-jn6gb6 ай бұрын
you did not tell about the value of zp provided
@mrdipesh45816 ай бұрын
Ye Truck ka horn q dal diya hai😅
@SouvikCivil7 ай бұрын
Thanks for explanation, very useful.
@VPlayer-i57 ай бұрын
upar upaar bataya. detail me kuch nhi bataya 😢
@r_rules_N7 ай бұрын
184 kaha se Aiya Sir
@madihasaeed42837 ай бұрын
Very well explained
@pravinchoudhary90377 ай бұрын
Tooo good ❤❤❤
@bikashbhattacharjee70817 ай бұрын
Sir please make videos on step by step mix designs according to FAA and ICAO
@HollywoodMovies123447 ай бұрын
step jump kar kar ke sikha rahe ho
@HollywoodMovies123447 ай бұрын
step 5 me Zprovided 348 kaha se aaya aur Z required 234 kaha se aaya
@HollywoodMovies123447 ай бұрын
sir bht mistake hain calculation part me
@sudwijawarade27097 ай бұрын
Plzz give IS code page nos also
@onlinepg40669 ай бұрын
How you get 97.40 % please exapalin
@se_22_vishal569 ай бұрын
❤❤❤
@viveka2669 ай бұрын
How tension and compression is developed.....
@RahulGupta-ur5xz10 ай бұрын
How to determine the diameter if load is given...
@mjunaidlive638710 ай бұрын
Nice explanation
@DSME-MallikarjunKattimani10 ай бұрын
Sir can u explain in shear strength formula what is the other area in th formula which u have considered as zero directly .
@mahendrasinhjayantibhaibar484910 ай бұрын
Fub is 5×100×0.6= 300 Sir
@martinmtotera28211 ай бұрын
good and perfect!
@VickyKumar-lu4pe11 ай бұрын
Better than my professor thanks...
@azizkhanwazir667211 ай бұрын
Good explanation my concept is very clear about this topic ❤❤
@civilshiksha11 ай бұрын
Keep watching
@nicolasmarie439811 ай бұрын
I believe we can calculate the load from the slabs S1 and S2 to the beam AB by getting the area of the two trapezoidal portions which is 2 Nos x 1/2 x (5+2) x 1.5 = 10.5 m2. We then multiplied the total area of 10.5 m2 x 8.75 kN/m2 and you get a total load of 91.875 kN to be carried by the beam AB. However using the UDL method (?) as you did we get a sum of 23.12 kN/m which when multipled by the length of the beam, we get a higher value of 115 kN. Further to this, we must add the Wall Loads to the beam, the self-weight of the Beam and then add the factor to be able to truely use this information in day to day job. Please go through that difference between the UDL and the area method. I have done this with another example, again the area method (which is nearer to Etabs calculation and result) has a lower value when doing the UDL.
@martinmtotera28211 ай бұрын
the value of 91.875KN will still be a trapezoidal load on beam AB. The formula of converting trapezoidal load to equivalent UDL is given in Reynolds'' Reinforced Concrete handbook and that's what Pritesh Bhana has described. I understand that apart from loads from slab you are supposed to add beam self weight and wall loads if any, but the emphasis from the author is on converting trapezoidal load to equivalent udl
@razzpiyushmehta390511 ай бұрын
Sorry I have only one liked buttom 🥹❤❤❤ thankyou thankyou so much keep itt
@khalidusman3705 Жыл бұрын
Thank you so much sir
@SagarMishra-r9n Жыл бұрын
P ki value
@svsms9157 Жыл бұрын
Very bad
@diyadeb Жыл бұрын
Sir how to remember all the value
@khontsuen Жыл бұрын
Tiada sarikata susa faham.🥴
@tur2230 Жыл бұрын
Sir in step two for Design load you have denoted by (Pu) and in the last step you have denoted (Pu) as applied load . which is correct?