#028

  Рет қаралды 5,720

Tony Albus

Tony Albus

Күн бұрын

Пікірлер: 27
@inamrehman8709
@inamrehman8709 4 ай бұрын
Thank you for the useful video, I have a question, can I use this with room air cooler to save electricity . its power is 300 watts on 220 Volt AC current.
@TonyAlbus
@TonyAlbus 4 ай бұрын
You can check the relay.. if the relay can switch 2 Amps and 220V or more, you are good. it should be printed on it. if it says less, you can use this small relay to switch a bigger stronger relay that can switch more power.
@derekriehl8036
@derekriehl8036 4 ай бұрын
Thank you - exactly the setup and test I was seeking! Order placed.
@TonyAlbus
@TonyAlbus 4 ай бұрын
Thanks, its an older video, great it still has some value.
@DemoMTL
@DemoMTL 10 ай бұрын
Quick Question, does the temperature controller store temperature settings provided in case of power loss ?
@TonyAlbus
@TonyAlbus 10 ай бұрын
Yes mine does.
@Joshua-ju5uc
@Joshua-ju5uc 2 жыл бұрын
I'm tryin to program my thermostat to heat up an aluminum block. settings 77.5. P0-H, P1 - 0.1, P2 - 89, P3 - -50, P4 - 0, P5 - 0, P6 - doesn't give me options. HOWEVER when the temp hits 50 the Thermostat turns off. The LED shows ( - - - ) What is going on?
@TonyAlbus
@TonyAlbus 2 жыл бұрын
Hi Joshua, i don't think you have the W1209 ..that one only has 1 setting.
@stephenshop4946
@stephenshop4946 Жыл бұрын
Can this w1209 be supplied with 13.3v from lifepo4 battery pack?
@TonyAlbus
@TonyAlbus Жыл бұрын
Hi, i think up-to around 14 volt will be no problem.
@stephenshop4946
@stephenshop4946 Жыл бұрын
@@TonyAlbus thanks for the reply
@justforheckofit
@justforheckofit 3 жыл бұрын
I am using two of these - one on a mid. eff. furnace vent and one on a standard vent hot water tank to switch on a motorized fresh air intake damper for combustion air in the basement. Have them wired in parallel so either of them will open the damper when at least one appliance is burning. In the instruction data sheet it states the static current draw is 35 mA and max draw 65 mA. So old 12V DC charger of 150 mA does run both of these. I think I bought these some time ago out of curiosity for about cad$10 combined. If I would use a mechanical thermo disks, if I could find suitable temperature parameter ones, they would be about cad$25 each. Considering a 60,000 BTU furnace will suck almost 4 cu yard of air in 10 min run, it helps to have fresh air coming in, but only as needed.
@TonyAlbus
@TonyAlbus 3 жыл бұрын
Thanks, yes that is a nice aplication of one of these devices... thanks for sharing Martin!
@aaronn6725
@aaronn6725 3 жыл бұрын
Do I have to worry about the amps or not really? Do I just need a 12v adapter? Does it need to be DC or AC? I have one myself but I am a little hesitant on hooking it up because I ruined one already. Thank you for this video
@TonyAlbus
@TonyAlbus 3 жыл бұрын
Hello Aaron, The board itself needs 12V ... the isolated relay contact can switch Max. 5A at 240 VAC or Max. 10A at 24 DC. Maybe this helps: www.kelco.rs/katalog/images/17670.pdf a manual i found some were.
@aaronn6725
@aaronn6725 3 жыл бұрын
@@TonyAlbus perfect that answers most of my questions. I just have one more question. Will a 12vdc 1amp be okay to use or should the amps be a little higher. If you believe I need a higher amp. What would you recommend. I do apologize.My question might have been answered somewhere but I’m not very good with good with this stuff. I’m still learning.
@TonyAlbus
@TonyAlbus 3 жыл бұрын
Hello Aaron, i think 1 Amps is okey, the relay will only use 1 or 200 mA bit more or less, 1 Amp should be fine for just the controller, good luck with your project
@aaronn6725
@aaronn6725 3 жыл бұрын
@@TonyAlbus you’re amazing! Thank you so much for answering my questions and making such a great, understandable product review! You definitely got me as a subscriber!
@TonyAlbus
@TonyAlbus 3 жыл бұрын
@@aaronn6725 You are Welcome and thank you!
@stephenshop4946
@stephenshop4946 Жыл бұрын
What is the lifespan of this w1209?
@TonyAlbus
@TonyAlbus Жыл бұрын
Good question, i think depends a lot on the enviroment its used.
@jimpon
@jimpon 2 жыл бұрын
Hey tony, ik heb hem gebruikt voor een incubator te maken. Ik had er twee besteld maar de relais bleven precies hangen. Het ging ongeveer twee dagen goed. Dan kwam ik thuis en was incubator afgekoeld tot 20 graden. Als er een tikje opgaf schoot hij terug in gang.De ene keer werkte hij, de andere keer niet. In mijn ogen waren deze dus alles behalve betrouwbaar. Grtj
@TonyAlbus
@TonyAlbus 2 жыл бұрын
Schakkelde je misschien een te zware stroom of zwaar inductief?
Thermostat Controller W1209 for Incubators
11:21
Saravanan AL
Рет қаралды 12 М.
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 57 МЛН
Do you choose Inside Out 2 or The Amazing World of Gumball? 🤔
00:19
Worst flight ever
00:55
Adam W
Рет қаралды 30 МЛН
W1209 Temperature Controller Setting
10:54
POWERGENTEK
Рет қаралды 6 М.
How to set Temperature Controller W1209 for Air-conditioning
9:26
Camz Creative
Рет қаралды 36 М.
#024 NanoVNA H4 - Review
15:33
Tony Albus
Рет қаралды 6 М.
TA-0422: Siglent SDS824X HD vs Rigol DHO924 - 12 bits - Hands On
28:04
An Unknown Ending💪
00:49
ISSEI / いっせい