11,000 Volts: The Thrilling Rush of Gas Engine Cable Installation!

  Рет қаралды 3,296

HV Sparky

HV Sparky

Күн бұрын

Пікірлер: 19
@ukbullylife7968
@ukbullylife7968 3 ай бұрын
Top tier terminations 💪🏽
@hvsparky
@hvsparky 3 ай бұрын
Nice and straight forward to do! ☺
@ElectricRob
@ElectricRob 6 сағат бұрын
Thanks for posting this - really shows the difference between these high voltage connections versus something like 208V or 480V - not just a simple insulation strip and apply a lug!
@hvsparky
@hvsparky 6 сағат бұрын
Glad you enjoyed it! In the new year i’ll be posting alot more videos 🤝🏻 Hope you had a good Christmas and happy new year 🥳
@grifftech
@grifftech Ай бұрын
What is that outer bit of copper wire for is that a ground?
@hvsparky
@hvsparky Ай бұрын
The screen wires disperse the circulating currents of the HV cable 👍🏻👍🏻
@ProductionSession
@ProductionSession 3 ай бұрын
cant believe you terminating a CHP engine. Are you at a energy facility, biogas farm, sewage plant or just energy recovery. Mate I'm in the process of doing a gas or steam fired CHP using a lorry engine to power my farm, warehouse and factory plus a bio digester to make more gas. I love this wish you took more moving pics of inside engine and generator type maybe control board, Please do a longer one if you are still on site mate. Awesome amazing job
@UKsystems
@UKsystems 3 ай бұрын
Just wondering with this high voltage works that you often do is it often high current or is the cable simply very big because it runs along distant at high voltage as it seems kind of counterintuitive to use a very big cable whilst being high voltage or is it all about voltage drop?
@hvsparky
@hvsparky 3 ай бұрын
Im not the person that designs what cable goes in where, but usually to do with loading in terms of what size cable goes in.
@TronicUK
@TronicUK Ай бұрын
It’s a 185mm conductor but it’s made of aluminium . The copper equivalent would be roughly half the size . At this voltage a 2MVA transformer only needs around 100 amps per phase on the primary side to output 2000 amps on the secondary side. To conclude 185mm aluminium isn’t very big …
@samuelchamberlain2584
@samuelchamberlain2584 3 ай бұрын
Probably stupid question but what is the copper armour for , bonding? I presume 3 phase 11kv delta
@hvsparky
@hvsparky 3 ай бұрын
Hi mate, no it isn’t a stupid question, basically the screen wires disperse the circulating currents of the HV cable.
@persona250
@persona250 3 ай бұрын
Where’s your earth sleeving 😂
@hvsparky
@hvsparky 3 ай бұрын
The 3mm on the van won’t fit 🥴😂
@chubbychubs4636
@chubbychubs4636 9 күн бұрын
I like to see red cables, they look dangerous for all the stupid people out there 😊
@bentheguru4986
@bentheguru4986 3 ай бұрын
Thought these were gas turbines but are just 4-stroke gas bangers. Far from efficient these turds, diesel wins every time but I spose, grid supplimenting and gas is all that is there. Single turbine would hand them a new cake-hole. Sorry but video was boring a bat-s###, was exptecting more.
@hvsparky
@hvsparky 3 ай бұрын
Sorry Benny, i don't know a lot about gas generators, or diesel. I'll make sure my next video aint like bat s##t 😱
@bentheguru4986
@bentheguru4986 3 ай бұрын
@@hvsparky All good buddy, you had way more patients for those way over-complicated terminations than I did back in my day but then again, we were dealling with LV, not HV (well, we topped out at 1,100VAC). When you get a look at a Gas Turbine in operation, you will have a huge learning expirience.
@UKsystems
@UKsystems 3 ай бұрын
These aren’t meant to be efficient, but they’re meant to be quite cost-effective and quite instantaneous for power so it’s worth it then sometimes
How to Install a Transformer - Let's Break Into It!
18:44
Electrician U
Рет қаралды 33 М.
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
I dont usually point out other tradesmens' bad work, but...
22:57
Jointech Cabling
Рет қаралды 9 М.
TWISTED: The dramatic history of twisted-pair Ethernet
28:30
The Serial Port
Рет қаралды 323 М.
This is how many things were wrong before id even stared!!
25:48
Jointech Cabling
Рет қаралды 6 М.
Switching 11kV VCB Tamco
7:34
competence 33kv
Рет қаралды 2,7 МЛН
Trying To Reinstate Old Victorian Lantern Wiring + Removing New Work
16:15
N Bundy Electrical
Рет қаралды 21 М.
Melting Copper Wire Into a River Table
16:53
Burls Art
Рет қаралды 2,8 МЛН
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН