12 Big Mistakes in Beam Before Concreting Work at Site | Beam Checklist | Learning Civil Technology

  Рет қаралды 86,487

Learning Civil Technology

Learning Civil Technology

Жыл бұрын

Reinforcement lapping Zone as per IS Code 13920 in Column
• Reinforcement lapping ...
What is Development Length in Beam Column Footing and Pile Cap
• What is Ld | What is ...
Development Length Value for Different Grade of Concrete for Practical Use at Construction Site
• Development Length Val...
How to Derive Development Length of Bar Formula as Per IS 456 2000
• How to Derive Developm...
How to Calculate Development Length of Bar as Per IS 456 2000
• How to Calculate Devel...
What is Ld | What is Development Length in Beam-Column Footing and Pile Cap | BBS
• What is Ld | What is ...
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
• What is Lap Length | O...
Difference Between Development Length and Lap Length
• Difference Between Dev...
Cutting Length of Lap Length and Development Length
• Cutting Length of Lap ...
What To do if Lap in Column Comes in Zone A
• What To do if Lap in ...
Which Bar should be Staggered during lapping in Column? | Upper or Lower
• Which Bar should be JO...
How to Calculate Rolling Margin of Reinforcement Steel at Site for Billing
• How to Calculate Rolli...
Circular Cover Block in Column | Round Cover Block क्या हैं? | Importance of Round Cover Block
• Circular Cover Block i...
Download Latest IS 13920 : 2016 pdf
learningtechnologyofficial.co...
12 Big Mistakes in RCC Beam Construction | 10 ग़लती बीम बांधते समय होता है | Learning Civil Technology
#learningciviltechnology #civilengineeringvideos #RCCBeamMistake #BigMistakeInBeam
*****************************************
JOIN US ON
✔Telegram: t.me/LearningCivilTechnology
✔Instagram: / learningciviltechnology
✔Facebook: / learningtechnologyoffi...
*****************************************
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
CONTACT DETAILS
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Linkedin: / civilengineermukeshsah
Disclaimer:-
Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.

Пікірлер: 245
@pavanmutsakarla1722
@pavanmutsakarla1722 7 ай бұрын
The way of yor explanation is love it sir.❤
@SatyamSingh-vg8je
@SatyamSingh-vg8je 7 ай бұрын
Thanks sir for this knowledge sharing session 🙏
@premnathdaram2929
@premnathdaram2929 Жыл бұрын
Your all lectures are so helpful to each and every civil engineer....🙏 Hook length should be 10D as per IS code
@user-hw2vk2us2r
@user-hw2vk2us2r 3 ай бұрын
8D also can take
@sauravbasu1344
@sauravbasu1344 8 ай бұрын
Very informative video.
@aaliyahkhan8565
@aaliyahkhan8565 5 ай бұрын
Very detailed teaching
@gauranggshah7135
@gauranggshah7135 5 ай бұрын
Lovk ringgit details excellent point. Also on some extra stirrups are provided. Your comment please.
@tharindukanchana4516
@tharindukanchana4516 7 ай бұрын
Thank you 🙏
@bbjconcreteindia
@bbjconcreteindia 7 ай бұрын
Very very informative video
@kiranm25x
@kiranm25x Жыл бұрын
You are doing Gods work by educating new house builders 🙏 Thank you Sir
@parmarpravin7666
@parmarpravin7666 Жыл бұрын
Good...Mukesh sir
@vaschouhan15
@vaschouhan15 Ай бұрын
Very very nice and useful information sir ji 🙏😊👌👌
@RoamNRides
@RoamNRides Жыл бұрын
Very Imp Topic
@katyanrajroy4123
@katyanrajroy4123 3 ай бұрын
Nice one and useful
@pammipandey1605
@pammipandey1605 Жыл бұрын
Gjb boss mja aa gya
@sazzadhussain46
@sazzadhussain46 10 ай бұрын
Good Sir, Bangladesh
@XYZ.96
@XYZ.96 5 ай бұрын
6d V v nice Way of teaching And the knowledge also👍
@shailenderayadav788
@shailenderayadav788 28 күн бұрын
Good.teacher.and.teaching.good
@gauranggshah7135
@gauranggshah7135 5 ай бұрын
Your lectures are like refresher course. Some place double binding wires are used.Your comment please .
@AD13D
@AD13D 11 ай бұрын
Super...
@omkarshinde7672
@omkarshinde7672 9 ай бұрын
Best information
@pappalarameshwarrao
@pappalarameshwarrao Жыл бұрын
nice teaching
@RONIKFF777
@RONIKFF777 12 күн бұрын
So super
@dipalimore3420
@dipalimore3420 6 ай бұрын
Sir, slab checking baare mein bhi video batao plz
@engramjadalikhan7739
@engramjadalikhan7739 4 ай бұрын
Very good 🌹 From Pakistan
@shrikantmaurya6896
@shrikantmaurya6896 6 ай бұрын
Sir ji, bhut achi video banayi hai apne, samjhane ka tarika apka bhut hi acha lagta hai sir Mujhe, me apki mostly video dekhta hu or share or comment bhi or like bhi krta hu sir ji, or sir ji ab to me pure confidence se interview deta hu, sir ji me abhi CBRI roorkee me job kr rha hu, thank you🙏🙏🙏🙏 sir ji
@majibuddinahmed6584
@majibuddinahmed6584 9 ай бұрын
Wow ❤❤
@upenpaikofficial
@upenpaikofficial 11 ай бұрын
I love you ❤❤❤❤❤ From Kolkata
@apuromeogamer8005
@apuromeogamer8005 8 ай бұрын
Sir last wala samjha nehi mai ek mistri hoon, aur mai apki video kafi dino se dekh raha hoon, please sir last wala acche se samjha sakte ho
@civilengineer0007
@civilengineer0007 Ай бұрын
Very good mistri sahab
@ksumit31
@ksumit31 Ай бұрын
stirupps in beam connecting columns should be plcaed closer near the columns and spacing should increase in the middle ?
@muhammadmurtazanasir9393
@muhammadmurtazanasir9393 3 ай бұрын
Best video
@ejazsaleem9621
@ejazsaleem9621 6 ай бұрын
Plz explain about RCC slab reinforcement
@YogeshLohar93
@YogeshLohar93 Жыл бұрын
Sir,ek aur point hai column junction se pehla beam ka stirrups maximum 50mm ke andar aana chahiye..
@sandeepchaurasiya3123
@sandeepchaurasiya3123 Жыл бұрын
Sir mix design me standard deviation ka kya role h. Please ek detail video laiye is pr.
@user-cj6mi1ye6b
@user-cj6mi1ye6b 9 ай бұрын
good
@rizwankhan-cv5mv
@rizwankhan-cv5mv 9 ай бұрын
Love from Pakistan ❤
@SyedAli-vz2id
@SyedAli-vz2id Жыл бұрын
Sir where it mention in IS code spacing of cover block 0.8 m.
@apurvabhagwat6943
@apurvabhagwat6943 4 ай бұрын
@hrishabhkumarsingh4118
@hrishabhkumarsingh4118 5 ай бұрын
Position of hook should be in compression zone. Like in continuous beam, tension zone is around upper part of beam-column junction.
@Entertainmentmanoj423
@Entertainmentmanoj423 11 күн бұрын
सर❤❤❤❤❤❤
@prabhatkumarpanda4438
@prabhatkumarpanda4438 5 ай бұрын
Sir Plz look up where the bottom lapping zone...u said that the lapping zone in bet L/6... I thought the lapping near column we can't provide..it may be after L/6..once check
@meaifollowyourdreams5196
@meaifollowyourdreams5196 3 ай бұрын
Yes agreed with you...I learn from some videos it says that lapping of bottom bar near the support is not allowed....length of effective depth multiple by 2 should be measured from column and just after that length we can provide lapping of bottom bar in beam...... (Depth of beam-bottom cover-half dia of main bar=effective depth × 2). I'm not an engineer but I learn everyday from multiple videos of engineer....the reason I learn and watch several videos of house construction it is because I want to build my own house with my own hand and idea only..so learning and taking ideas from many people is good..😊😊
@arunkumarkarn1995
@arunkumarkarn1995 Жыл бұрын
A/c to new abundment IS 13920:2016 ,6d hona chahiye or 65 mm in place of 10d or 75mm
@soumyadipdas7307
@soumyadipdas7307 8 ай бұрын
Sir mere ghar ke chad ke middle beam mein plastic nehi diye the, cement slurry gira tha waha se bohot, abhi tak koi problem nehi hua but in future koi problem ho sakta hai ???
@abhishekpanigrahi1288
@abhishekpanigrahi1288 10 ай бұрын
Stirrups hook length has been updated in the latest amendment as 8d, pehle 6d tha aab 8d hai.
@ChansparepartsTangra
@ChansparepartsTangra 9 ай бұрын
Bhai 18x120 feet shop ready krna hai Piller dimension bta do plz Down beam ki bhi Niche basement and uper ek ground floor hai
@user-hw2vk2us2r
@user-hw2vk2us2r 3 ай бұрын
About your question: as per 13920: 2016, the minimum hook length in the RCC beam and column. Answer is c) 6d
@denanathsingh9554
@denanathsingh9554 11 ай бұрын
Thanks! Sir.6d hota hai.
@devcpwd
@devcpwd Жыл бұрын
As per seismic zones ke Hisar se Kya hai lap zone
@pratikchikhale8860
@pratikchikhale8860 Жыл бұрын
Master ring to column may provide karte hai na over the slab
@LearningCivilTechnology
@LearningCivilTechnology Жыл бұрын
Yes... Lekin yaha beam ki baat ho Rahi hai...
@kamleshgoyal9389
@kamleshgoyal9389 4 ай бұрын
Sir column ki bars ko cut kaise krna hota h after 2 nd floor or 3rd floor columns and so on .I mean kitni length tak cut krke rkhna hota h
@LalitKumar-ps2ho
@LalitKumar-ps2ho 4 ай бұрын
Sir, j bolt ki details in foundation m kasa lagata h Or j bolt ki kya kya check karte h
@hinaajannabum3871
@hinaajannabum3871 2 ай бұрын
Neutral Axis kya hota he? Or reinforce steel ko kese layer mey dalna he?
@ejazsaleem9621
@ejazsaleem9621 6 ай бұрын
Master Ring.. plz explain
@kughazhechophi7469
@kughazhechophi7469 3 ай бұрын
Mukesh brother could you kindly clear my query. If the column size is 9×12 inch does it include cover block space of concrete or otherwise. BDW i'm not from civil engineering background so kindly suggest your valuable info in this regard. Thank you in anticipation.
@LearningCivilTechnology
@LearningCivilTechnology 3 ай бұрын
Yes... It includes
@kughazhechophi7469
@kughazhechophi7469 3 ай бұрын
@@LearningCivilTechnology ty
@YogendraYadav-jq6nn
@YogendraYadav-jq6nn 8 ай бұрын
May I request you to show master ring in beam in 3D view
@nawazshariff9217
@nawazshariff9217 2 ай бұрын
In beams top bars lapping length should be 50d and for bottom bars lap length should be 28d..
@AD13D
@AD13D 11 ай бұрын
6d or 65mm by is code 13920..
@user-xn5zo3mq7h
@user-xn5zo3mq7h Ай бұрын
Top bair zont L/3 ushae aige sir
@khairullaskar596
@khairullaskar596 8 ай бұрын
Pole ka size 5 floor ke liye kitna dina he
@XYZ.96
@XYZ.96 5 ай бұрын
If you feel easy Then BN Dutta explain
@stephenantony7513
@stephenantony7513 8 ай бұрын
Jee ready Karo video about soil test
@MohitSharma-po2eb
@MohitSharma-po2eb Жыл бұрын
In some cases, development length is exceed to beam depth then what will be the development length
@LearningCivilTechnology
@LearningCivilTechnology Жыл бұрын
Make it in C shape...
@naveeng8549
@naveeng8549 5 ай бұрын
😂 How to place the bar when two ends is the same situation
@gauranggshah7135
@gauranggshah7135 5 ай бұрын
Hook length 6d
@dharmesh11
@dharmesh11 Жыл бұрын
e L/6 Lap zone konse code me hai?
@abhijeetlahane7372
@abhijeetlahane7372 11 ай бұрын
As per Is 13920:2016 is 6d
@nyabombam3897
@nyabombam3897 5 ай бұрын
C) 6d.
@bhoomiarora
@bhoomiarora 7 күн бұрын
Pl clear IS516 part4 B-2.5.1 ,
@HimanshuS5
@HimanshuS5 Жыл бұрын
Beam and column ka jaha junction banta hai ya T banta hai vaha column me stripes nahi daal pate hai beam ke steel ki vajh se to vaha kya kare .
@PintuKumar-uc2wl
@PintuKumar-uc2wl 5 ай бұрын
C) 6D
@veerkumarchoudhary5704
@veerkumarchoudhary5704 Жыл бұрын
Ans.c)6d ~65mm.
@user-bn3wx1xd8u
@user-bn3wx1xd8u 7 ай бұрын
Can we use marble pieces as cover block?
@Nick32176
@Nick32176 7 ай бұрын
absolutely no.
@user-bn3wx1xd8u
@user-bn3wx1xd8u 7 ай бұрын
@@Nick32176 dear friend cover block are not available in Pakistan. Generally people use marble pieces. What is solution?
@Jaswindersingh-pp4cs
@Jaswindersingh-pp4cs Жыл бұрын
Typical footing drawing mai likhte ish kya matlab hai ❓❓❓❓ battye bahi
@LearningCivilTechnology
@LearningCivilTechnology Жыл бұрын
Same type
@nsoni8644
@nsoni8644 2 ай бұрын
Hook length must be 6d as per latest norms.
@pansulsatpathy309
@pansulsatpathy309 5 ай бұрын
6D FOR HOOK LENGTH
@tirkey09
@tirkey09 3 ай бұрын
6d Sir
@kishorjadhav635
@kishorjadhav635 8 күн бұрын
6d sir
@aaliyahkhan8565
@aaliyahkhan8565 5 ай бұрын
I need bent up bar knowledge.
@MukeshDhimanKumar-bp9st
@MukeshDhimanKumar-bp9st 5 ай бұрын
Hook binding 135degree
@balasubramanianmurugan5395
@balasubramanianmurugan5395 7 ай бұрын
C) 6d
@anupamraygupta8473
@anupamraygupta8473 Жыл бұрын
6D.
@Raunakvilog4124
@Raunakvilog4124 6 ай бұрын
(C) 6D
@sigmarules4048
@sigmarules4048 5 ай бұрын
Ans 6d ans
@ramgopalgupta7838
@ramgopalgupta7838 11 күн бұрын
6D
@davidkurbah934
@davidkurbah934 10 ай бұрын
If possible with 3d shapes
@RajeevKumar-xy8bx
@RajeevKumar-xy8bx 6 күн бұрын
6d
@arvindsharma4706
@arvindsharma4706 9 ай бұрын
C. 6D
@brown.gentleman
@brown.gentleman 2 ай бұрын
Sir agar 3D main dakha dete toh pura clear ho jata
@Nagendrakumar-vj2re
@Nagendrakumar-vj2re 6 ай бұрын
Please Mack videos pile load test
@Nagendrakumar-vj2re
@Nagendrakumar-vj2re 6 ай бұрын
6D
@souravpanda505
@souravpanda505 6 ай бұрын
Sir, Master Ring & Lock Ring are not same! Master ring is the main ring of a beam but lock ring partly called as Horizontal ring
@narinderjoshi3914
@narinderjoshi3914 4 ай бұрын
10d
@kailashpanchal9032
@kailashpanchal9032 2 ай бұрын
Hook 6d hona chahiye as per IS code
@vijaykadam2026
@vijaykadam2026 10 күн бұрын
6 D
@vikasthakurcivilengineer5458
@vikasthakurcivilengineer5458 Жыл бұрын
C = 6d
@ajitseal2486
@ajitseal2486 7 ай бұрын
Ultra Tech ppc cement 53 grade kaise pata kare
@AlaminShaikh-ru3xu
@AlaminShaikh-ru3xu Жыл бұрын
10D
@user-me8ix3vh7p
@user-me8ix3vh7p 29 күн бұрын
6
@GkYaduwanshi
@GkYaduwanshi 6 ай бұрын
Good morning sir 6d par hona chahiye
@mdazad459
@mdazad459 6 ай бұрын
C 6d
@mohd.ibrahim737
@mohd.ibrahim737 Ай бұрын
6 d
@bheemanagoudpatil
@bheemanagoudpatil Жыл бұрын
6d length
@mdislam4187
@mdislam4187 9 ай бұрын
Cantelever beam ?
@devcpwd
@devcpwd Жыл бұрын
IS 13920 me to likha hai joints or middle quarter me lap nahi karna hai.pleade clear
@shortvd969
@shortvd969 7 ай бұрын
Han ek dmm sahi kah rhe ho
Calculate Centre To Centre Distance Of Bar for 4-legged, 6-Legged, 8-Legged Stirrups
14:33
Common mistakes of steel fixer during plinth beam steel fixing.
4:37
my Civil Technology
Рет қаралды 39 М.
Basic Rules for Lapping length in Beam - Lap length in RCC Beam || By CivilGuruji
8:18
Civil Engineers Training Institute
Рет қаралды 806 М.
What is Lap Length | Overlapping | Lap Splices in Beam | Column | Footing and Pile Cap
14:59