I really thanks to u sir My name is yusuf ali I like ur videos Thank you so much sir for giving us such a great knowledge about ac and HVAC pls keep giving
@mohdaarif90474 жыл бұрын
Welcome sar
@ARSHADKHAN-fo9eb3 жыл бұрын
Nice video sir
@jafarmuhammad55844 жыл бұрын
Sir ap buhut acha kaam kr rahe hain.ap detail se samjhate hain. Sir compressor loader unloader pr video banay plz
@ahmadrzk21454 жыл бұрын
Sahi baat bole h sir
@razvivlogs964 жыл бұрын
Aap bahut ache hain sir
@girishshinde4 жыл бұрын
Thanks
@shailendrajadon35994 жыл бұрын
Nice video
@girishshinde4 жыл бұрын
Thanks
@ganeshkamble68924 жыл бұрын
Understood well. 1. 15 Bends. 2. 10 cm. 3. Insulated Suction pipe, Insulated Liquid pipe, Drain pipe and Electric cable. 4. Case 1 - When outdoor unit is below indoor unit, Inverted U loop is provided in the suction line. This is done to avoid the liquid refrigerant flowing back to the compressor and damage the compressor when it starts. Case 2 - When outdoor unit is above indoor unit, U trap is provided in the suction line. This is done to return the oil back to the compressor and save the compressor from failing (wear and tear) due to lack of lubrication oil. 5. To maintain the efficiency of ac unit by keeping proper flow of the refrigerant in the unit, the distance between indoor unit and outdoor unit is kept minimum. If the distance increases then there will be pressure drop and load on the compressor will increase. This will reduce the efficiency of the unit.
@abidhussain77222 жыл бұрын
Sir kaise samjhe konse ac me kitne size ka copper pipe lagega
@RajKumar-uc7zz2 жыл бұрын
all gas ka saction,discharge ,standing paresar ka chat dakhai ya lakhava
@anwarulislam13924 жыл бұрын
If conceals piping how make we my u loops?????
@coolindiaenterprises60144 жыл бұрын
Sir u trap inverter technology Jo aajkal Ac aa raha hai usmein bhi Dena hoga
@girishshinde4 жыл бұрын
Yes
@AsmatAli-hs9bf4 жыл бұрын
Nd what is the accumulator work....?
@girishshinde4 жыл бұрын
Prevent liquid flood back to compressor
@suchitgupta87554 жыл бұрын
Good
@girishshinde4 жыл бұрын
Thanks
@bidhanmondal71584 жыл бұрын
Additional refrigarant charging in pipe length ka video banaya
@shaikhabdulqadir1354 жыл бұрын
Good explanation.. I have one query girish sir, if we installed except of split unit we have vrv outdoor at terrace in any bldg and all indoor connected down side in bldg room so is it possible to make u bend in vrv outdoor side to avoid oil issue in indoor.
@girishshinde4 жыл бұрын
I have to check that
@girishshinde4 жыл бұрын
Vrv has different system for oil recovery and to liquid flood back. I will go through it and come up with new video. But spli ac dose't eqqupied with such systems hence it requires bends
@shaikhabdulqadir1354 жыл бұрын
@@girishshinde thanks for your prompt reply, ok noted sir for your clarification on concern query. Thanks a lot for your hard work for making such a informative videos.
@snowball17184 жыл бұрын
Please make HVAC job & future scope related vedios for Engineers, so that students will get motivated to make future in this line & will watch more n more vedios of this channel.
@girishshinde4 жыл бұрын
Great idea
@patelandbrothers4 жыл бұрын
Good information
@hasmatansari64854 жыл бұрын
Love you sir
@SanjeevKumar-lv7xj4 жыл бұрын
Sir , 40*90 feet ya 3600 sq feet ke hall ke liye kon sa ac system shi hoga .kya isme central ac lagana chahiye ya fir split ac bhi effective ho jayega?
@indian_ranger38054 жыл бұрын
Bhai three phase wireing......full detail of 3 pahse outrer working and wireing
@SanjaySharma-jr7bp4 жыл бұрын
Indor piping and ,water dranege piping & u, s bend tells us.
@abhijeetsinghsisodiy4 жыл бұрын
Sir plz teach 1) cold room(data and covept) 2) evaporative cooling 3) weather maker/ahu room 4) central heating system 5) industrial heating 6) ventilation requirements Mechanical and other 7) building management system 8) AHU practical concepts 9) circulating water pumps 10) ducting in RAC PLANTS 11) ENERGY RECOVERY WHEEL and economiser 12) power cabling in HVAC and motor used and relays used 14) testing and commissioning of central AC plat 15) desert cooler
@girishshinde4 жыл бұрын
ok I got your topic
@parwezkhan93484 жыл бұрын
sir ek split ac hai usme paip chhota huwa to me 5/8 paip ke bich me 1/2 ka paip joint kiye hai karib 6 miter to isse koi problam ho sakta hai kya rply plz
@gargaircon65694 жыл бұрын
Koi problem nai h
@syednoorshaik92334 жыл бұрын
Hi sir, please explain different between Enthalpy and Entropy
@sunilkumar-cd3ew4 жыл бұрын
Nice video sir Sir HVAC ki training kaha se mil sakti hai.
@syednomankhadri86604 жыл бұрын
Please make a video for calculation of pump head in chilled water systems...
@syednomankhadri86604 жыл бұрын
1)AHU design calculation.. 2) ESP AND ISP calculation video
@surajsinghrawat38024 жыл бұрын
Sir mere split AC ki outer unit se Pani tapk rha h bich m se fan k nich direct please sir mujhe batao
@girishshinde4 жыл бұрын
Indoor unit ya outdoor unit?
@starseven77924 жыл бұрын
agr kesi waja sy piping ko lamba karna par jye tu phr kitny Gram refrigerant ko additional charge karna pary ga Max pipe lenght kitni honi chye or minimum pipe lenght kitni honi chy ??
@roushanshadab51534 жыл бұрын
Sir two way thermostat setting pe ek video banaye plz wireing to kardete h per tharmostate se sitting nahi hota h plz detail me video banaye
@AhmadElectricals7874 жыл бұрын
Bhai light focua Karo apne face per
@ShabbirKhan-zh9ut4 жыл бұрын
Sir inverter split A/C ka indoor and outdoor unit pcb ka connection and system kaise kam karta hai uspe video banaiga please thanks
@svsirsasirsa11104 жыл бұрын
Pipe under ground h Saare fer
@almohemmedi46724 жыл бұрын
Sir The way of Explaining is Awesome, Thanks for the video... Sir I have a question is there any range of minimum piping?? Means 10foot of copper piping is necessary to install the machine ?? Please reply me