Can you say more about the practice of sizing up timber for efficiency (5:45)? When would you not do it?
@Buildsum2 жыл бұрын
Hi Alex, hopefully you could apply it in all cases however it would depend on what you supplier could supply.
@action-nerd2 жыл бұрын
@@Buildsum thank you, this was not something I've seen mentioned before, much appreciated!
@huanengneng2 жыл бұрын
hanging beams be hung to counter beam or fixed to counter beam using metal hanger?
@Buildsum2 жыл бұрын
Hi Mate, this video may help kzbin.info/www/bejne/jpiwimZ_h7BjaM0
@MrThatguy2172 жыл бұрын
What grade/type of wood is the tables specified for? Lvl or radiata pine etc
@Buildsum2 жыл бұрын
Hi Mate, all these tables are for MGP10.
@afghanwariror89382 жыл бұрын
Bravo buildsum 👍👍👍
@Buildsum2 жыл бұрын
Thanks Mate.
@abdulmasri1411 Жыл бұрын
Why would you pack the combined counter/strutting if the hangers are connected to it, if the beam deflects so would the ceiling and hangers
@Buildsum Жыл бұрын
Hi Mate, I get your point however this is what is specified in AS 1684.
@action-nerd2 жыл бұрын
Another Q! I require a long strutting beam: two strutting beams supported at 3 points in total. It's not clear to me what is best practice for joining the 2 strutting beams atop the middle support. The beams are likely to be quite tall at 2/190 to 2/290, depending on timber selected, and will have laterally restraint at each support per Figure 7.18. A: Would it be a half-lap joint, like for underpurlins with skew nails (AS1684.2 Figure 7.6)? B: Or, a mitre joint with skew nails per Figure 9.3? C: Or, a butt joint with metal brackets per Figure 9.3 but the through bolts would be up to 300mm long? D: Nail plates sides, skew nails top, laterally restrain with strap? (edit): Is the butt joint out of the question, because the bearing area at the end of the beam must be 70mm, or does the fixing of the joint negate this? (support is 90mm wide)
@Buildsum2 жыл бұрын
Hi Alex, yeah with that 70mm bearing everything but a staggered joint is out of the question.
@action-nerd2 жыл бұрын
@@Buildsum this is what I was thinking. I assume staggered in this case means a half lap
@Buildsum2 жыл бұрын
More like a lapped joint like the one in this video at the 1:10 mark kzbin.info/www/bejne/bKizdqiOlqaCmMk
@punjeet83472 жыл бұрын
hello there, just wondering how do i determine where best to set my combination beams?
@Buildsum2 жыл бұрын
It is generally determined where your struts require support and if they can be used to support the ceiling as well. This video may help kzbin.info/www/bejne/jpiwimZ_h7BjaM0
@punjeet83472 жыл бұрын
@@Buildsum thank you so much, I was just wondering if it was ok for me to send you a photo of how I wanted to place combination beams is there any other way to contact you
@chow110008 жыл бұрын
hi, is the combined strutting/hanging beam must has 25mm clearance from the ceiling joists?
@Buildsum8 жыл бұрын
Hi Ray Yes any strutting beam combined or not must have a 25mm packer between them and the plate
@chow110008 жыл бұрын
Thanks
@linaibrahimi72565 жыл бұрын
Hi John , how do I workout the beam size that’s directly under a load bearing wall of the upper story house
@Buildsum5 жыл бұрын
Hi LIna, as far as i know this would fall outside the scope of AS 1684, Basically unless you can transfer the load directly on to a wall in the lower storey you would have to get a Structural engineer to design something for you.
@linaibrahimi72565 жыл бұрын
Thanks
@xAzx28 жыл бұрын
Hey, how would you join hanging beams to combined counter/strutting beam. Would you just use metal hangers, or would it be stronger if you notch the hanging beam over the counter/strutting beam and then also provide the metal hangers?
@Buildsum8 жыл бұрын
+Az Hi Az these days metal hangers are considered to be sufficient but naturally notching them over the beam would be stronger and also acceptable Hope this helps
@rogerlz3497 жыл бұрын
Hi John, I just checked TABLE A33, there is no strut spacing at 3600mm in the table. Maybe our tables are different?
@rogerlz3497 жыл бұрын
I FOUND I USED SIMPLIFIED TABLES, THEY ARE DIFFERENT
@Buildsum7 жыл бұрын
HI Roger Yes AS1684.4 uses different tabel to AS1684.2
@rogerlz3497 жыл бұрын
thank you John, could you have look my plan give me some idea, please.
@lukeaustin23102 жыл бұрын
Sounds exactly the same as the blue dog explanation
@Buildsum2 жыл бұрын
Hi Mate, seeing we would be both delivering the same information from the same standard I would hope so.