i only framed for about 9 months, but what my boss told me when i asked questions about headers, was that the rule of thumb, was that for every foot that your header ran, you transformed that measurement into inches per your header. so if i had a 3 foot wide window or less, then i used a 2X header, and if i had a ten foot opening, then i used 2X10's for my headers, and if i went over 12 feet, then i would use an L:VL. he also told me that this rule was more used for cantileavers, but also applied to cut out openings, but wasnt absolute. i understood that as basic one story building methods, because obviously, at least to me, if you are building a 2 or 3/4 story house, then your headers become more important, and things like bla bla bla come into play. anyways though, ive always used this method that i was taught, to make my headers, and i pretty much always use the sandwich method myself, but im not a pro, im just a get er done side contractor, but i dont exceed my knowledge level, and ive gotten more work out of being honest about my skill limits than i have about pretending im an engineering guru, but anyways, i do want to ask if what i was taught is at a basic leve, a decent foundation to go off of?
@JadyGrudd5 ай бұрын
Wish I could answer
@A-ei7vm3 ай бұрын
it depends on the loads coming down (snow loads differ depending on area, a gable wall has less roof load coming down than a hipped wall). but I calculated a few different scenarios and it works. the capacity is usually at 85%, so definitely enough. it did fail in cases where I assumed a bigger width of the house or higher snow zones up north.
@Marigold-ip3gw7 күн бұрын
I’m building an off grid cabin next summer. Your videos are exactly what I needed to help me with areas I wasn’t 100% knowledgeable about. Thank you so much!!
@superbanobano2 жыл бұрын
you are a great teacher, I'm glad I found your video, Thank you for sharing your knowledge.
@ConstructionEd2 жыл бұрын
You are very welcome - thank for joining us
@thomask48367 ай бұрын
Joe, you truly have a gift for making things easy to learn! Thank You Sir!
@ConstructionEd7 ай бұрын
Thanks for watching! You should see the blooper reel
@thomask48367 ай бұрын
@@ConstructionEd - LOL! I worked for 30 years in railroad technical training so I appreciate good videos when I see them! I've been retired for almost 10 years now but I also enjoy learning from KZbin and I am grateful that you took the time to do a GREAT job! Woodworking has always fascinated me but framing has been a mystery to me and you all really have the knack for making it easy! Again, Thanks So Much! Take Care, Tom
@jjc35510 ай бұрын
These are the best framing videos I've ever seen. Thanks 👍
@ConstructionEd10 ай бұрын
Wow, thanks!
@Eskaledi29 күн бұрын
Absolutely natural teacher
@xxnonstopdancingxx Жыл бұрын
UK subscriber here. Just want to say thank you for these videos. Lots of cross Atlantic carryover here. Really great delivery and pace
@ConstructionEd Жыл бұрын
Glad they are being viewed across the pond
@Daniel-w5e3j14 сағат бұрын
this was extremely informative and I thank you for the knowledge!
@RcFlyer49 Жыл бұрын
These videos are incredibly helpful. Thank you. I especially appreciate the time and effort that went into making the models.
@ConstructionEd Жыл бұрын
thanks for visiting and thanks for your comment
@psubash16039 ай бұрын
Thank you very much for the clear explanations on header. As I am new to QS, I have been taking more than 8 days to get clarified. once again thank you very much....
@yourmasterrenovator86 Жыл бұрын
Amazing! The very last point that you mentioned (Jack studs don't stop by the window header BUT goes all the way up to the top plate) was crucial to me. I learned a lot. I really appreciate you and your lessons. Thank you kindly 🙏
@SaleenJ9 ай бұрын
Literally answering my questions as I think of them, wow, good work, subbed.
@ConstructionEd9 ай бұрын
Awesome, thank you!
@lorenkelley15682 ай бұрын
I found this to be very useful, and the presentation was well-done. Thank you! I'm a DIY considering building a second, smaller house in my back yard. I will definitely be watching other videos in this series.
@tringsby6 ай бұрын
Thank you! Sometimes you stumble over great videos and teachers online, and I’m very happy to have stumbled over yours. Just the content I’m looking for! Love the scale models you have made to illustrate how everything goes together!
@ConstructionEd5 ай бұрын
Gald you found us, I hope you like the other videos on our channel
@Emeraldcoastking Жыл бұрын
I cannot believe you do not have millions of subs man you're amazing.
@ConstructionEd Жыл бұрын
Thanks - Maybe someday our subscriber count will be higher. Please Subscribe, Share, Like, and comment whenever you can. It helps
@Deep_Divers Жыл бұрын
Thanks for all the information packed into your videos! Great presentation!
@ConstructionEd Жыл бұрын
thank you very much
@Zi.Zenior Жыл бұрын
This is very well produced and super informative. Thank you
@ConstructionEd Жыл бұрын
thanks - we do work hard on making educational videos
@toddperry9860 Жыл бұрын
Excellent information and very easy to understand, great job!
@ConstructionEd Жыл бұрын
thanks Todd
@chrisalister2297 Жыл бұрын
Always have enjoyed woodworking and construction shows. This is a very informative series. Enjoying breakfast while learning. 👍👍
@ConstructionEd Жыл бұрын
I hope you had a good breakfast, eggs and building lessons always go well together.
@junkemboxx831310 ай бұрын
the problem with the high header is that when framed that way, the 2x across the top of the opening doesn't provide enough nailing surface for the next trade that comes after you. As a lath and plaster contractor, the 2x is so tight that it provides little nailing surface for the lather to attach the wire to. Remember the window flange is anywhere from 1.25 to 1.50 inches out from the window and covers most of the 2x's face across the opening. this requires either blocking above the 2x across, or cranking up the nail gun and shooting through the window flange. When the header is low, there is ample space for nailing across. Framers frame to the drawings, but they need to be aware of what is going to be done all the way the interior/exterior finish. otherwise good video
@CE-ex2wg8 ай бұрын
Im doing a blueprint class and this was very helpful, thankyou!
@ConstructionEd7 ай бұрын
You're very welcome!
@Mahaveer_S3 күн бұрын
Just came across one of your videos, loved the content, loved your presentation. Your style of explanation is so simple and clear. Liked & Subscribed
@T.E.P..10 ай бұрын
Hello from Monday, January 15, 2024. So great to discover your channel. New Subscriber here. Thanks for making the vids and doing a superb job explaining to the world what this "mystery" is behind building. Happy New Year!
@ConstructionEd10 ай бұрын
Welcome aboard!
@rickyrichy54963 ай бұрын
I just learned what Jack and kings are. Thank you sir
@luismatos22392 жыл бұрын
Muy bueno Maestro, su explicación y detalles Son bien entendidos Gracias de nuevo Se le agradece Bendiciones 👍
@ConstructionEd2 жыл бұрын
Thanks for the comment and enjoy the other lessons
@wooddogg8 Жыл бұрын
That was very helpful, soon to be installing a 71" window, will definitely follow these guidelines! Thanks!
@ConstructionEd Жыл бұрын
Glad to hear it. We also have a video on window installation.
@62Cristoforo9 ай бұрын
Excellent presentation; no fluff, gets right to the point. I have a question about sandwich headers built on-site. Rather than simply nailing the assembly together why not glue and screw together? Is this too time consuming? Nailing seems like an inferior method compared to ‘glue-and-screw’
@lanalali41735 ай бұрын
This man is AMAZING 🤩 I can’t believe you don’t have a million views on day one. Thank you so much 🙏🏻 Definitely subscribing to your channel. Keep it coming I clip on how to build a deck and pergola would be great 👍🏻
@ConstructionEd5 ай бұрын
Wow, thank you!
@dwaynedayes3984 Жыл бұрын
You are a very good teacher
@ConstructionEd Жыл бұрын
Thank you! 😃
@stefboulas2 жыл бұрын
Excellent video
@ConstructionEd2 жыл бұрын
Thank you very much! - I hope you watch more of our videos in the framing series. More are coming each week.
@mikanikolic19764 ай бұрын
Thanks a lot for the clear explanation!
@larrykent1965 ай бұрын
Good stuff, thanks for the well done video and explanation. Cheers!
@wendellgustafson5 ай бұрын
Very informative, well explained
@ConstructionEd5 ай бұрын
Glad you liked it
@jeanchery72465 ай бұрын
Great teaching 👍
@ConstructionEd5 ай бұрын
Glad you think so!
@juliehenderson1672 Жыл бұрын
Thank you! Great series.
@ConstructionEd Жыл бұрын
You're very welcome!
@robertorondan3676 Жыл бұрын
Thank you for your valuable information
@ConstructionEd Жыл бұрын
You are welcome
@Vikaskumar-sc8kq Жыл бұрын
Thank you so much for kind of information ❤️ it's really help to understand header. I really want you to upload some videos on estimate lumber framing
@ConstructionEd Жыл бұрын
Noted - that may be available in the future
@ScottDoler90002 ай бұрын
Something good on the internet...FINALLY
@ConstructionEdАй бұрын
That is what we thought, so we did something about it.
@wilsonfineart Жыл бұрын
Great teacher!
@ConstructionEd Жыл бұрын
Thank you! 😃
@adambrown6532 Жыл бұрын
so nice for a giant to teach us how to build
@ConstructionEd Жыл бұрын
Joe is a little over 6 feet.
@thudang3039 Жыл бұрын
This is awesome! Thank you!
@ConstructionEd Жыл бұрын
You're very welcome!
@miketriggiano983 Жыл бұрын
Great videos! Thank you!
@ConstructionEd Жыл бұрын
glad you liked it
@matthewkoch4529 Жыл бұрын
Ok, i make this harder than it has to be apparently. How does the header get fastened? The 2*6 commected to the king stud on each side? What about if the header is at the top and that 2*6 is connected to the top plate? Screwed in from the top through the double plate and then into the header? I can't imagine a huge 8 inch screw from the bottom to fasten through the 2*6 and into the top plate..... Yeah, beginner here. Thanks in advance
@ConstructionEd Жыл бұрын
sorry for the delay Matt. You can connect the header by face-nailing through the King Studs. Also - if you have a high header you can face nail through the top plate. The jack studs are taking the weight, and the fasteners are there just to keep in all in place
@herefornow967110 ай бұрын
@@ConstructionEdwhat an incredible resource!!! I am THOROUGHLY impressed This channel is a GOD send Thanks for ALL you are doing
@robstevenson6753 ай бұрын
Thanks for your videos. They’re very helpful. Now I’m wondering about combining the single header method and the top header method. Doing that it seems as if the upper header plate could be the wall’s top plate, with the single header below that and the lower header plate finishing up the header. Would that be workable? I like that it would eliminate one piece of wood, for both a cost savings and a heat transfer improvement. But would it work structurally?
@Trainman040110 ай бұрын
Great video….. Question…I am installing a prehung double door that is 65 inches wide in a non load bearing wall in my basement. Can I use 2 flat 2x4s nailed together as a header or is the span too large? I want to avoid purchasing a sheet of 1/2” plywood to make a sandwich header? Thank you for providing such informative content.
@ConstructionEd10 ай бұрын
Since the header is non-structural, you don't really need a header - just use some 2x4 framing. But it is likely you want something to fasten your drywall to above the door - I am assuming. In that case, you can use some other material to fill the 1/2 if you really want something in place of a header.
@mingueyox9 ай бұрын
Fantastic video. Would appreciate more coverage on the window sills though. Split Jacks vs Continuous Jacks vs Continuous Jacks with Cripple Studs. Why are Split Jacks not meeting code in some jurisdictions? Continuous Jack would force to use toenailing and does not look super reassuring, especially in situations with only one cripple... would love to see a video on that topic (and apologies if I miss one talking about that) thanks again for the great content, much appreciated
@ConstructionEd9 ай бұрын
In our opinion, Jack Studs should not be split. A sill can be end nailed through the face of the jack if the RO framing sequence is done in a way that allows. You will see folks frame with extra framing members under a sill at the ends. - I call them stilts because they are not true cripples. The false argument for those framing parts is that the sill holds more weight. I call this a false argument because the sill does not need to hold more weight - the windows are fastened to the RO - very little weight is actually on the sill. Advanced framing techniques encourage less lumber rather than more. We say if the lumber is not required, it should not be added.
@mingueyox9 ай бұрын
@@ConstructionEd Thank you very much for your quick and thorough answer Joe 👍👍👍 All that make sense, indeed. In my current situation I am looking at designing a rough opening of about 10F that will actually not receive a window frame but a counter top. I suppose that in such scenario adding stilts could make sense. I was also thinking about adding a double sill as well. Many many thanks for your feedback and all your videos. They are well made and very instructive 🙏
@thomasmurray78205 ай бұрын
For the single ply header, why isn't the header centered to make an I-beam shape? Wouldn't that produce the same % area void, but be structurally stronger? As it is, it sorta seems like the design would have "load bearing" insulation
@VP411Designs9 ай бұрын
Great helpful channel, learning alot! One question is for running electrical wires, or HVAC Plumbing & electrical or otherwise from attic down to 1 Level ceiling on a 2 level building! Can you cut 1"/1.5"/2" diameter holes on both the double top plates/cap & top on exterior or interior walls framinged in? Will any of these cuts/holes made in any sizes mentioned above in any location throughout both of those two top plates hinder or disrupt the integrity to the strength of that wall?
@donewithit19849 ай бұрын
AWESOME videos. I really love the models. In the videos showing engineered headers, they appear to have two Jack Studs on each side. Is this common for larger openings with bigger headers (and bigger loads)? Is there a rule of thumb, or would the engineer specify this condition? EDIT: Next time I'll watch the entire video before asking a question. ;)
@johnjohn-ne8fw Жыл бұрын
Again I say....thank you 👍
@ConstructionEd Жыл бұрын
Thanks again!
@gnomo23687 ай бұрын
Thank you.
@ConstructionEd7 ай бұрын
You're welcome!
@wambliokiyan8 ай бұрын
At the 6:35 minute mark on your video, you have what appears to be a stained pallet wall behind you. Looks great. I'm using pallet wood in my music studio / office in the basement and would like to know what stain you used. Thanks in advance. PS: Framing information is quite helpful.
@ConstructionEd8 ай бұрын
We cheated and that was from a pre-stained kit we bought from one of the big box stores - I think it was Home Depot
@ConstructionEd8 ай бұрын
But it could have been the blue store
@wambliokiyan8 ай бұрын
Thanks for the info!
@michaelchurchill18894 ай бұрын
As a carpenter for 46yrs ,I can endorse your teachings Sir, Thank you
@RONNIEJNZN Жыл бұрын
Around 8:30, the single ply header, would you carry the cripple down into the header also ?
@SinglehandedSailing Жыл бұрын
Ronnie - yes the cripples would travel from the top plate to the header in this drop header configuration - the image at 8:30 is "section view" to show the orientation of the framing member.
@carlosbourdet54152 жыл бұрын
I would quibble with the illustration on 7:34-8:36 I've always called the two plates at the top the "double top plate", the lower plate being the "First plate" and the second one being ........ "the Second plate"😉. I think that the way they are drawn might confuse students because the "Top plate" is under the Cap plate.
@thesinglestringtheory2 жыл бұрын
Thanks always for the input and for watching. There are many regional differences in terms and some builders even develop their own naming. We at TEACH try to find the most accepted and descriptive terms. You know how tricky this can be for a global audience and so many times textbook terms are not always used everywhere or by all. The cap plate (or lesser used term "crown plate") clearly describes the uppermost position in a wall. I believe anyone learning framing would struggle with understanding your preferred term "first plate" as it's name does not indicate its location in a wall frame. To a newbie, "first plate" could possibly suggest the bottom or sole plate. As for "Second plate" - if i know nothing about framing this might be a single top plate but I am unsure. Remember, a wall with a single plate only at the top is always referred to as a "top plate", so an additional one stacked above makes the group a double top plate as you said. With three basic terms used in the most current version of the IRC - top plate, double top plate, and cap plate, walls built with either a single or double top plate can be described with less confusion and a student is also being primed for learning building code (IMHO). I think we can both agree that communicating clearly through terms is just as important as tool and measuring skills when working in the field. Props to you for caring and the feedback is very appreciated!
@ConstructionEd2 жыл бұрын
I have to agree with Joe. Bottom plate, top plate, and cap plate. The last two making combined making a double top plate. Start with the text book terms and then move to field terms
@vipero00 Жыл бұрын
11:30 For a window in a high header situation the bottom of the rough opening is the sill. What is the purple member that defines the top of the rough opening called?
@ConstructionEd Жыл бұрын
When the header is install high, the framing member at the top of the RO is really just a nailer. I have heard it called a header plate, or a nonstructural header, we sometimes call it a header plate. But I don't think there is an "approved" term for that member.
@schlz693 ай бұрын
in 2X6 walls, we double up usually 2X12's and push them to the outside, leaving 2.5" space for insulation, or place a piece of 2.5" foam between the 2 2X12's
@Trainman0401 Жыл бұрын
Fantastic videos! Question…I am building basement walls with doorways. Since the walls are not load bearing can I build my door headers using 2 - 2x4’s laid flat and nailed together? Thank you so much!
@ConstructionEd Жыл бұрын
Yes, absolutely. You can also just use one 2x4 as a header. It is not carrying any additional load, it is just needed to hang the door
@wildburpp Жыл бұрын
thank you!
@ConstructionEd Жыл бұрын
You're welcome! And thank for visiting the channel
@Shadetree_Medic Жыл бұрын
Your a great instructor, I teach a carpentry class in my local adult program. What are the dimensions of those studs for the scale model you have there? I'd love to use models like those.
@ConstructionEd Жыл бұрын
Check out our channel for teachers - www.youtube.com/@TEACHConstruction Here is the link to a video about the scaled lumber kzbin.info/www/bejne/lXKZpmOlhp56q9k
@joeb-51507 ай бұрын
We always referred to the jack studs as cripples, i guess terminology varies in different areas
@aloizmeze4786 Жыл бұрын
Thanks
@ConstructionEd Жыл бұрын
you are welcome
@sarentopi15023 ай бұрын
Can I bore a 3 inch hole through a window header for plumbing, venting, hvac, etc?
@tommyclinton1531 Жыл бұрын
Are headers required if stud is not load bearing. i.e. small office in existing garage.
@ConstructionEd Жыл бұрын
Headers are only required if the wall is load-bearing. If you are adding an interior partition wall you can use the same size framing lumber as the studs in place of a structural header. You are mainly creating an upper framing member to frame in your door and a place for the trim to be nailed to.
@geniehn2 жыл бұрын
For the exterior openings, the framing member right at the top of the rough opening shall be designed for wind loads. While it's not an issue with small openings, it's can be a problem if this member is not sized properly for much wider opening especially when the real header is raised up against the double top plates.
@ConstructionEd2 жыл бұрын
You can meet the wind load requirements as separate from load capacity of the header
@theok4712 Жыл бұрын
What are your thoughts on the oversized header that attaches to the underside of the top plate with another 2×4 or 2x6 attached to the bottom of the header to define all the rough openings in house which in turn eliminates all the cripple studs. I've been seeing that a lot in new builds.
@ConstructionEd Жыл бұрын
The high header placement is becoming more and more popular - I am personally a fan. But the header does not have to be oversized
@yoshi-wr8xy4 ай бұрын
Does osb ply need to be continuous in the inside of the a sandwich header ?
@donaldlee67602 жыл бұрын
Great video - I'm interested in learning more about the math behind determining the number and size of the header beams to support a certain span width. I assume the same header can support the same span regardless of if it's dropped or raised and in contact with the top plate so is there another benefit for using the "modern" header placement of raising it to the top?
@ConstructionEd2 жыл бұрын
I learned some of the Math in my Structural Analysis class at school, not terribly fun. Now most folks just look at the IRC code book and use those tables - or of course just do what the engineer told ya to do, lol. Yes the high header can carry the same load as the drop header - in fact it can carry a bit more when it is up tight against the top-plate. The other main benefit for a high header is later remodeling. It is nice to be able to increase the height of a window without having to replace a header...
@hulltacemergencymeddr.hull4370 Жыл бұрын
Excellent. What is the best way to attach a thicker Header to a thicker top plate (2, 2x4 on Edge). Thank you.
@ConstructionEd Жыл бұрын
Not sure I understand your question. When you ask about "attaching" are you asking the types of fasteners? If you are referring to the board orientation - typically a structural header has the boards on edge.
@bevgeigle91664 ай бұрын
what type of loading will the one layer header carry? my husband spent 56 yrs. in architecture. he questions this for loading, the header has to require so much loading per lf. He has designed many headers for his architectural career and questions some of these modern technics of todays construction.. to design any header you have to know total loading per lf.. which is easy to do. with his 56 yrs. he questions some of this stuff.. He looked at some new houses being framed this way and notice some real deflection for a garage door header openings.
@ShawtiiThiicke9011 ай бұрын
Can you do like a kreg jig to attach to the top of your frame ?
@fabricationgranite5003 Жыл бұрын
lI am learning a lot!!
@johnnynephrite61473 ай бұрын
If you were going to expose a gluelam header wouldn't you want it to deep enough to extend out past the drywall?
@OmarAzize-p8m9 ай бұрын
Can I cut 1 stud in the lower half from a LBW and add a header on that lower half.
@_BenjaminManuel Жыл бұрын
You're a great teacher. Where do I sign up?
@ConstructionEd Жыл бұрын
we have courses at TradeSkillsU.online
@normbograham2 ай бұрын
i had a 100 year old house, where the beams, are a bunch of 1.5-ish inch lumber, nailed in two directions. there are three layers. outer layers go right to left. inner layer goes up and down. No glue, no construction adhesive. span is about 14 foot. Since it's rough cut, it's not pine, and not spruce. I'm thinking it's not hemlock, but the siding was hemlock. Note, there is no plywood in the building originally.
@peterbergeris6510 Жыл бұрын
Would you put adhesive for the foam board n then screw the two 2x4s?
@ConstructionEd Жыл бұрын
Today - I would purchase insulated headers or build a box header. But if I am making a simple sandwich header, then adhesive is not required
@stephennisewander9393 Жыл бұрын
I'm installing a pocket door on a load bearing wall. How many jack studs do I need for my header on either side?
@ConstructionEd Жыл бұрын
Number of jack studs are determined by span and the load above. Determine the load and you should be able to find a header sizing table online or in ICC code.
@strutherspatrick4 ай бұрын
Can you confirm for how many king and jack studs I would need for a 16'-18' opening. Douglas County Colorado. Thank you.
@ConstructionEd4 ай бұрын
Sorry, we can not provide you with engineering - but you will still need to consider several factors to take the load above into account. You will need to know the planned materials , the number of stories etc. codes.iccsafe.org/s/IRC2021P2/chapter-6-wall-construction/IRC2021P2-Pt03-Ch06-SecR602.7
@strutherspatrick4 ай бұрын
@@ConstructionEd thank you for the advice.
@juliehenderson1672 Жыл бұрын
Do you have a video addressing the space between the 16 on center vertical boards that provide a "chimney" effect? Re: fire safety.
@ConstructionEd Жыл бұрын
We cover some of that in the blocking lesson, which can be found on the playlist.
@AllFallBeforeMe6 ай бұрын
What about shimming a header to eliminate gaps? Can a window slowly be destroyed if you have floating headers that slowly settle?
@ConstructionEd5 ай бұрын
If the header is sagging and pushing on the window it can cause damage. But the best solution would be to rebuild the opening.
@cornpop78052 жыл бұрын
The one downside of the high header, is a loss in the fastening area for window dressings. Other than that, it makes sense.
@ConstructionEd2 жыл бұрын
They do make sense in many install situations - Blocking is always easy to add if needed.
@cornpop78052 жыл бұрын
@@ConstructionEd Rather than a high header and blocking, I would simply use a low header.
@masoudnobar631411 ай бұрын
🙏
@MAVENdeNYC2 жыл бұрын
Do you have a video showing a opening for a door on an elevation vs subgrade? That is, crawl space vs basement foundations. (Up north is mostly basements, and in the south crawl spaces.) Also what differences if any between those rough openings with balloon framing? Great series btw. I'm currently doing remodelling again, and these technical details is where I'm having trouble.
@ConstructionEd2 жыл бұрын
I am not really sure what you are asking about - the RO framing is the same over a crawl space or a basement. If the RO is in the foundation - then those are typically supported with the concrete wall and then header in place - sometimes that is in metal. Then the rest of the RO is framed out with wood so the door has something to connect to. But this construction would typically be called out on the plans and approved by an engineer. I could be wrong - but the RO framing is the same for balloon framing - but you should consult a Structural Engineer since I assume you are talking about a multistory building since you referenced balloon framing. Especially if you are dropping in a RO where there was not one before.
@JoseGonzalez-jh9ne5 ай бұрын
With the wall being load bearing Can I use 2x4s as headers for door opening of 24 inches?
@ConstructionEd5 ай бұрын
Not a good choice for a load bearing wall. The ICC code book will give you header size guidelines
@WhiskeyPapa4211 ай бұрын
I'm curious about the single ply header. One would logically think the single ply would be right down the middle, like an I-beam, allowing some insulation on each side. I would think that with the single ply just on one side, there is a weakness in the structure on the other side due to not being in balance. The load of the wall is down the middle, not the side, and I-beam construction, be it metal or a wooden I-joist, is "I" shaped for a reason. How is the strength of the header not impacted when moving the support from the center to the outside (or inside) edge?
@ConstructionEd11 ай бұрын
While you are likely correct that moving the header from the middle to the edge could result in less strength. But the additional strength is not needed.
@gen5420 Жыл бұрын
What type of header is best for a garden shed?
@ConstructionEd Жыл бұрын
It all depends on the load from above. On sheds, the doors are often in the gable wall with very little load to worry about.
@DavidGalan777 Жыл бұрын
For a 5 foot wide window, can you make an open box header with 2x6s' instead of getting a single ply header ???
@ConstructionEd Жыл бұрын
it all depends on the load above - there are tables in building code to help determine the permissible header
@stevehdd992916 күн бұрын
The builder on our house used the concrete form boards from the slab for the headers inside the house. I've never seen that before. What are your thoughts?
@ConstructionEd16 күн бұрын
While I think that process is unacceptable and just plain crappy, I can not come up with something that makes it structurally wrong. You said "inside" the house, so I am thinking that you mean non-load-bearing interior partition walls. In that case, they are really just nailers.
@stevehdd992916 күн бұрын
@ConstructionEd Thank you for the response. They are all the main headers carrying the weight of the home. My main concern is the chemical in concrete that got into the broads. Anyways I'm upset about it, but the roof is already on now, and I'm not sure how big of a deal i want to make out of it.
@ConstructionEd16 күн бұрын
I think you are right for being a bit pissed, that is just shoddy work. Is this a production builder. I am assuming there is no insulation in the header since they were field built. What state are you in.
@stevehdd992916 күн бұрын
@ConstructionEd I'm in Oklahoma. The home is being built by cherokee nation, so it's not exactly a custom home. However, we still have to pay for the home, and it's on our own land. It's a little different, and we didn't hire the contractor. Their is an inspector that works directly for cherokee nation, but I don't feel like his heart is in it or wants to fuss much at the contractor.
@ConstructionEd15 күн бұрын
I understand, I have a friend who does a lot of work on a couple of the Sioux reservations. If you are still at the framing stage, you can certainly wash the headers to get rid of the concrete dust on the surface. Once the wall is sealed up, I personally would not worry much about it.
@duketran625 ай бұрын
Between High header and Drop header, High header seems providing more stability, why is it not commonly used? What is the disadvantage of it. Thank you.
@ConstructionEd5 ай бұрын
It is more commonly used now in production building. I agree that it is a better system, but change takes time.
@kurtb9402 жыл бұрын
I’m the last example would it make sense to break up the jack studs into two pieces or is that weaker?
@ConstructionEd2 жыл бұрын
Jacks should always be a continuous framing member. While I have see some people slips them, it is not a good idea.
@JohnGalland-ft3kl2 ай бұрын
What if header has to be above double top plate (e.g., an 8’ door installed in a 7’ shed wall with 18” gable peak)?
@ConstructionEd2 ай бұрын
You can get away with plenty for a shed. If you are building a door on the gable wall it is likely not load bearing and thus your header is not structural, it becomes more of just a nailer so frame it as you need to. I would frame the full gable wall as one section. Vs a 7 ft plus the gable section.
@JoshStaley2 ай бұрын
I’m a union pipe fitter so I have access to cheap Steel, I could not just use a 4 inch I-beam with 4 inch steel legs down to the floor
@ConstructionEd2 ай бұрын
You could. But steel is a bit hard to use as a backer for nails and screws later.
@chuckstires20388 ай бұрын
For a 12' sliding glass door on an exterior wall, it appears that a 12' 6" header is required with double jacks. How many kings will be needed? Thank you
@ConstructionEd7 ай бұрын
Code header tables for you location should call that out. Sometimes it is a double jack and a single king.
@chuckstires20387 ай бұрын
Thank you.
@norwoodsatv Жыл бұрын
What’s the minimum rough opening height for an exterior out swing door that’s 30 inches x80 inches? My opening height is 83 inches
@ConstructionEd Жыл бұрын
It depends on the door that you are installing. The specs will call out the dimensions, but with 3 inches to work with you likely have enough space
@lonnieclemens80287 ай бұрын
I didn't think a solid wood header would be considered a heat loss. Wood has 'R' value. But is the R value of wood less than insulation board? Log cabins are known for having good R value without insulation. Opinions please...
@ConstructionEd7 ай бұрын
Wood is about R1 per inch. Insulation is much higher
@charlesviner15652 жыл бұрын
👍
@ConstructionEd2 жыл бұрын
It looks like you are watching all of our videos Charles - keep it up
@lexylewis47594 ай бұрын
Greetings. Tried starting a new account on your website, but was futile. Please give me more information on how to go about it successfully.
@ConstructionEd4 ай бұрын
Sorry. Our site was down for a couple of hours today. It is back up now.
@kurtb9402 жыл бұрын
The open layout header feels riskier (I’m an absolute beginner just sharing thoughts). For example if you placed weight on the weak side of that open header where the insulation is I feel like you could have some major screw ups. Imagine building on top of that header you wouldn’t likely know that an entire side is hollow and could put weight on it in a way that could compromise it. Also I’ve heard that the first thing a piece of dimensional lumber wants to do is turn when it has weight on it (example in standing joists). Would this tumble effect be more likely to happen on the “weak” insulation side of the open header layout?
@ConstructionEd2 жыл бұрын
I often rely on the tables in the code and what the engineer has specified. I personally like the headers that are boxed with insulation in the middle.
@coyotech55 Жыл бұрын
I had never heard of that kind of header, and I was thinking the same thing. If I were a pro building from engineered plans, of course I would build it as shown. But I'm a DIYer building my house, and I don't think I'd do that kind! This was helpful. I have half my house built, and your videos show me where I went wrong (not many wrong spots, thank goodness), where I went right, and how to do it better on the rest of the house. There are so many practical things you only learn by doing. Like how do you handle it when most of your lumber is warped in at least one direction? I've gotten a lot better with that, but warped, twisted and splitting lumber is always a headache. Is there a video for that, other than to insist on picking out your own boards at the lumber yard?
@lolol71102 жыл бұрын
Two 2x4’s and osb in the middle adds up to 3 1/2 ? How ? 2+2 = 4 plus the osb . So what am I missing
@codywhitfield2002 жыл бұрын
3” + 1/2”= 3&1/2” Nominal number is 2x4 Actual is 1.5”x3.5”
@ConstructionEd2 жыл бұрын
Thanks for jumping in on the comment Cody - He is right, the actual dimension of a 2x4 is 1 1/2" x 3 1/2" - We cover that on our materials lesson video in detail.
@lolol71102 жыл бұрын
Thank you so much Cody
@lolol71102 жыл бұрын
Thanks . I’m subscribed now !
@assalhaddad1641 Жыл бұрын
wouldnt two 2X4s and a 1/2 inch layer end up being 4.5 inches thick and not 3.5? am I missing something? thank you
@ConstructionEd Жыл бұрын
No - a 2x4 is just the name of the framing materials. The Actual measurements are 1 1/2 '' x 3 1/2 ''