1957 Express elevator 2AC shaft

  Рет қаралды 228

Liftguy 30

Liftguy 30

Күн бұрын

Пікірлер: 10
@LiftsInQLD
@LiftsInQLD Ай бұрын
Your videos are awesome! 😃 You'd be surprised how much I'm learning about those units you've posted on your channel. I've seen a little bit of Schindler & Otis machines around and about thanks to technicians, but your videos really do go into detail as to the inner workings of these. As I'm over the ocean in Australia, I don't have that much knowledge regarding Express lifts, for example, so it's always good to see how things vary.
@philipcollins3849
@philipcollins3849 Ай бұрын
I remember back in the day no top of car inspection just a toggle stop switch and no shaft lights
@liftguy30
@liftguy30 Ай бұрын
@@philipcollins3849 still plenty out there just like that, some still don’t have pit stop switches
@philipcollins3849
@philipcollins3849 Ай бұрын
Maybe insurance companies are more stringent in the uk or less in NZ
@liftguy30
@liftguy30 Ай бұрын
@@philipcollins3849 insurance in this country are not interested in elevators, completely opposite of the UK etc
@elevatorsinnz
@elevatorsinnz Ай бұрын
I’ve filmed that one! I know because of the motor. That one is nice
@Lift.Tracker
@Lift.Tracker Ай бұрын
Why is it that this one has 5 inductor switches compared to the usual 3 if it only runs at two-speed?
@liftguy30
@liftguy30 Ай бұрын
@Lift.Tracker ZS does the counting (two pulses per floor) 2US and 2DS does the change over point from high speed to slow speed, and 1US and IDS do the stopping depending on direction
@Lift.Tracker
@Lift.Tracker Ай бұрын
@ I see. So is it because it’s such an old model that they hadn’t integrated both up and down slowing and stopping into 1 inductor, making it have just 3 in total?
@liftguy30
@liftguy30 Ай бұрын
@Lift.Tracker correct, to do so required a lot more relay logic and if you had short floors you may need the slowing steps too close together or even overlapping which wouldn’t be possible with only one inductor per direction. Most also had a “2S” inductor for door zone, this one didn’t as the original doors had a retiring cam to unlock them, so the door open circuit was integrated with the lock relays so unless relays “41” and “42” (locks) dropped the doors would not open, so when the doors were modernised I had to install an optical switch to run a door zone otherwise the lift would open the doors wherever it stopped (and potentially rip the landing pickups off if in the wrong place).
DMR elevator basic info and manual and silverstat switch
16:58
1957 Express elevator 2 speed AC slip ring motor
4:07
Liftguy 30
Рет қаралды 449
Хаги Ваги говорит разными голосами
0:22
Фани Хани
Рет қаралды 2,2 МЛН
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН
I BOUGHT an ABANDONED HOUSE & RENOVATED IT IN ONE YEAR | Start to Finish
21:32
Sweden's most secret weapon
15:28
Hidden in Sweden
Рет қаралды 141 М.
Soudan Mine Lift Motor
5:07
Mike Thompson
Рет қаралды 66 М.
Was 1960’s Marriot & Scott, ULP mod
5:32
Liftguy 30
Рет қаралды 126
Level 1 to 100 Science Experiments
15:53
Hafu Go
Рет қаралды 19 МЛН
3 February 2025
4:58
Liftguy 30
Рет қаралды 54
Otis Hydro (vintage controller) Elevator
4:27
Liftguy 30
Рет қаралды 274
Хаги Ваги говорит разными голосами
0:22
Фани Хани
Рет қаралды 2,2 МЛН