2023 250.64 Grounding Electrode Conductor Installation

  Рет қаралды 2,906

Ryan Jackson

Ryan Jackson

Күн бұрын

Пікірлер: 10
@davidicousgregorian
@davidicousgregorian 20 күн бұрын
It's basically for the same rule as you don't put electric wires in ventilation through a house or cut through it because if it's energized in any way either through electrical wires or through ground wires and there is an electrical charge on it that causes a spark or fire it could ignite inside the exhaust area and throughout the house.😊😊😊
@bretgreen5314
@bretgreen5314 Жыл бұрын
Love your explanations Ryan. Licensed Wyoming electrician here; been on an extended "hiatus." I do keep my State license up to date. I will say this: funny how quickly one gets "rusty" on the codes. Your videos are going to be my go-to when I get serious about freshening up. . .
@ElectricalTime
@ElectricalTime Жыл бұрын
Hi Ryan, thanks for creating these great videos here on KZbin, all the best, Steve Kavallaris
@enriquecontreras3608
@enriquecontreras3608 Жыл бұрын
Thank you so much for sharing your thoughts!!! I have some questions; What happens with the grounding of ladder trays and metallic wire ways? Should I grounded them? How can I do that?
@martinserena9314
@martinserena9314 Жыл бұрын
An electrician on one of our projects terminated his 2-inch primary and secondary conduits to the ventilation mesh in the bottom plate of a dry-type transformer. I imagine that this is a violation of 450.9? Seems to be the same theme as 250.64(G). Knocking out holes in the mesh appears to also violate the manufacturer's designated access areas.
@hughbrackett343
@hughbrackett343 Жыл бұрын
So can I run the Grounded Conductor through the ventilation hole? Maybe an EGC? They should just state that no conductors may be run through a ventilation hole.
@stillthakoolest
@stillthakoolest Жыл бұрын
So you'd be running the grounded conductor outside of a raceway separate from the other ckt conductors? Maybe a bonding conductor for the flex but thats about it
@paulburton8125
@paulburton8125 Жыл бұрын
No GEC, ok. What about GE's? Example, ground rod installed or rebar (min requirements met), turned up out of pad for access before pad poured and transformer anchored? GE's through ventilation holes. No GEC going through ventilation. GEC internally connected in enclosure. I know I may be being petty, but I've seen both examples in the field. Does the code address this type installation?
@chrisf3875
@chrisf3875 Жыл бұрын
I would throw a flag on the field, and call for a 5 yard/ do-over......
@chrisf3875
@chrisf3875 Жыл бұрын
The older you get, The more you understand common sense just isn't common.
2023 250.70 Termination Types for Electrodes
6:12
Ryan Jackson
Рет қаралды 1,8 М.
Raceway (conduit) Fill Pt 1
39:38
Ryan Jackson
Рет қаралды 14 М.
SISTER EXPOSED MY MAGIC @Whoispelagheya
00:45
MasomkaMagic
Рет қаралды 18 МЛН
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 11 МЛН
2 MAGIC SECRETS @denismagicshow @roman_magic
00:32
MasomkaMagic
Рет қаралды 9 МЛН
Try Not To Laugh 😅 the Best of BoxtoxTv 👌
00:18
boxtoxtv
Рет қаралды 4,2 МЛН
CUSTOM MADE BOW TIE FOR CATEYE
5:52
Austin Friloux
Рет қаралды 16
2023 230.85 Emergency Disconnect
15:19
Ryan Jackson
Рет қаралды 10 М.
Grounding, Auxiliary Grounding Electrode [250.54, 2020 NEC]
13:40
What is the Difference Between Grounding, Bonding and Neutral?
15:15
Table 250.66 How to Size GEC's Grounding Electrode Conductors
14:57
Electrical Code Coach
Рет қаралды 8 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,4 МЛН
NEC System Grounding
42:44
Ryan Jackson
Рет қаралды 35 М.
Electric vehicle circuit sizing (NM Cable)
12:36
Ryan Jackson
Рет қаралды 8 М.
Feeder taps and the 2020 National Electrical Code
28:25
Ryan Jackson
Рет қаралды 65 М.
Grounding and Bonding an Electrical Panel
13:24
Appalachian DIY
Рет қаралды 328 М.
SISTER EXPOSED MY MAGIC @Whoispelagheya
00:45
MasomkaMagic
Рет қаралды 18 МЛН