A tip that helped me as an appreciate was : split the circuit into two parts . 1 part control circuit and 2nd part is the main . Knowing that simplifies the wiring a bit more .
@UnimportantAcc Жыл бұрын
I wouldn't worry too much about meticulously learning the DOL. In the am2 you are provided with a wiring diagram, so it is very easy to see where the link cable is missing from.
@GSHElectrical Жыл бұрын
Thanks for the feedback 👍🏻
@slelectricaleducation129 Жыл бұрын
kzbin.info/www/bejne/gXeWh5Rorq6Iga8
@sunshine3187 Жыл бұрын
My dol wiring diagram today went L3-L2-L1 from left to right. Not L1-L2-L3.
@montystelevision3238 Жыл бұрын
Yes to when a GSH alert pops up.
@GSHElectrical Жыл бұрын
😁👍🏻
@montystelevision3238 Жыл бұрын
@@GSHElectrical Gaz. I’ve had an interesting email regarding the pulling of service fuses
@Death887589 ай бұрын
I WISH you would do a continuity test on this from a three phase board,there is no such thing on KZbin😢
@seanmcneill8899 Жыл бұрын
Very informative video on dol motor control. Thanks lads.
@baaagudubala1363 Жыл бұрын
You are simply the best
@GSHElectrical Жыл бұрын
Thanks for the support 👍🏻
@adamwright5553 Жыл бұрын
Just wondering could you post a photo of the single phase and the three phase DOL starter circuit diagram, would be handy to have when on site. Great video 👌
@GSHElectrical Жыл бұрын
Motors, Starters, Controls, Remote Stop Start - Single and 3 Phase kzbin.info/aero/PL2Ea5r9gxUUfv51Ld1UlNGR39rfFIExTU 👍🏻
@slelectricaleducation129 Жыл бұрын
kzbin.info/www/bejne/gXeWh5Rorq6Iga8
@joeldwarika8356 Жыл бұрын
Perfect.🎉🎉🎉tnx guys😊
@EdijsUmanecs Жыл бұрын
What is the benefit of using a contactor relay? Why not use 3 poles C32 Amper circuit breaker to use it as a switch for more simple schematics?
@princejoseph1349 Жыл бұрын
Thank you guys ,this is really helping
@laurabradley1857 Жыл бұрын
Hi - I love your videos and they have been super helpful in helping me prepare for my AM2s, however I managed to fail my Fault Finding. I know there is some description of a fault where the motor is 'juddering' or something similar but I cant for the life of me remember what the fault was or how to test and then rectify it. Can you help me with this? Thank you!
@GSHElectrical Жыл бұрын
Hi thanks for the lovely message. If a 3 phase motor was juddering it has lost one of it phases. Remember all faults on AM2S are found either visually or by dead testing. All the best and keep me updated 👍🏻
@laurabradley1857 Жыл бұрын
@@GSHElectrical I passed by the way!! Thank you! Loving life as a fully qualified spark now!
@abdulseaforth6930 Жыл бұрын
@@GSHElectrical yes Gaz- I see. By losing one of the sizes, it’s out of balance so it won’t run so smoothly. It will make sense!
@arjansingh4971 Жыл бұрын
How would u go on testing this using R1/R2??
@just_saw_dust Жыл бұрын
What about VFD. Lots of new IE2 & IE3 3ph motors are designed to be run from single phase supplies via inverters. I'd like to see this covered as a video with some reference to the way this works and is wired up with starters and remote controls.
Not specific to Motors but if the motor was turning the wrong way, this is the result of 2 phases being crossed... is this Polarity or is polarity only when the Neutral is involved? Would I just say crossed phases/conductors? I think the terminology I used was wrong last time & I don't want to make the same mistakes!
@toughshoe64089 ай бұрын
Do you install a single phase motor on 3 phase in your am2?
@GSHElectrical9 ай бұрын
3 phase
@seanpritchard2650 Жыл бұрын
How would you wire a 415v coil with a pressure switch