4 Inch Check Valve For Home Sewers Explained

  Рет қаралды 25,662

Balkan Sewer & Water Main Service

Balkan Sewer & Water Main Service

Күн бұрын

Пікірлер: 53
@davidking3311
@davidking3311 Жыл бұрын
Cheap insurance, I had a city main clog just past my house and I was lowest in the neighborhood so all of my upstream neighbors waste was dumping into my basement with pretty significant pressure behind it .
@balkanplumbing
@balkanplumbing Жыл бұрын
Agreed and exactly.
@monctonhandymanservices1015
@monctonhandymanservices1015 4 ай бұрын
The title of this video should be "Why I recommend a Cyclone brand check valve"
@balkanplumbing
@balkanplumbing 4 ай бұрын
So??? Great product.
@monctonhandymanservices1015
@monctonhandymanservices1015 4 ай бұрын
@@balkanplumbing Yes, you make that more than obvious.
@atkgrl
@atkgrl 16 күн бұрын
What if the city sewer is always clogged, so I put a clean out 25 feet before the backflow and immediately after between the backflow and city. The reason I’m searching installation is because it’s 3 ft down which I don’t want to dig up 2x every year.
@balkanplumbing
@balkanplumbing 16 күн бұрын
You can certainly have a clean out on the street side of the valve, just extend it above the flood level. If you have a house trap, no need to do that on the house side.
@davidfrankel5301
@davidfrankel5301 11 күн бұрын
I have a house in Sheepshead Bay but when I look at where the trap is located, its below the the concrete slab such that installing this before trap would involve busting up the slab. I guess you do that or someone else needs to be hired?
@balkanplumbing
@balkanplumbing 11 күн бұрын
I’d suggest you call us. We provide free and no obligation site visits. We all do complete installs after a proper assessment.
@davidfrankel5301
@davidfrankel5301 11 күн бұрын
@@balkanplumbing Will do.
@chrisgardner2548
@chrisgardner2548 10 ай бұрын
Thank you for your excellent videos. I do have a question or two relating to valve design. It appears there are two main types. #1 is the flapper style, and #2 is the ball valve type. Are both types legal in NYC in a sanitary sewer line. Are there any benefits to installing one or the other? In other words, is one type more or less prone to becoming fouled, or more difficult to maintain. Obviously, I would expect installation of the ball type may require some additional care to make certain the valve was installed carefully and accurately level to function properly. Whereas the flapper type may be slightly less critical installation-wise. But, the flapper itself may provide a catch point for debris. Curious to know your thoughts. I really appreciate your videos, and have learned a great deal of information from watching. Thanks Again
@balkanplumbing
@balkanplumbing 10 ай бұрын
Thanks for the positivity Chris. Much thanks. The check valve “flapper” is a very basic and inexpensive device. It is ideal for flash storms, as it does not hold back backwater 100%. A knife edged flood gate valve on the other hand, is a very sophisticated and highly engineered device. It holds back backwater 100% and for an extended period of time. It is likewise a much more costly installation. In both cases a site visit from an expert is required to determine if the location is a candidate for such a device, and to consider best options. Budgetary constraints can also be a factor. Hope that helps!
@chrisgardner2548
@chrisgardner2548 10 ай бұрын
Thank you for the reply. I apologize for perhaps not being clear with my question. I was seeking to compare the ball check valve vs the flapper valve type; both of which are shown on the manufacturer's website. Thanks
@NathanShort
@NathanShort 6 ай бұрын
​@@chrisgardner2548 I was also wondering the same thing. Did you ever get an answer to what the differences are?
@chrisgardner2548
@chrisgardner2548 6 ай бұрын
He did reply, but didn't really provide an answer to the question
@flipper2473
@flipper2473 21 күн бұрын
Hi, what would keep the water from unhinging the flap, it looks like it can lift off too easy? Thanks
@balkanplumbing
@balkanplumbing 21 күн бұрын
That would never happen. It must be manually removed for easier cleaning.
@flipper2473
@flipper2473 21 күн бұрын
I understand that it has to be manually removed, my concern is that is so so very easy to remove , that I wonder if rising forceful water could jar it accidentally.
@balkanplumbing
@balkanplumbing 10 күн бұрын
Again - no.
@-.__.__.-Rad
@-.__.__.-Rad 6 ай бұрын
how reliable are these over decades? My concern is 15years after installed, getting stuck - then what...
@balkanplumbing
@balkanplumbing 6 ай бұрын
They’re easily cleaned, the flapper replaced, checked or maintained, or swapped out entirely.
@kiernanparkman
@kiernanparkman 5 ай бұрын
Can toilet paper be flushed through this from the house side with no worries?
@balkanplumbing
@balkanplumbing 5 ай бұрын
Absolutely, and all drain waste as well. The flap should be cleaned about once a year or so.
@JosephTammaro
@JosephTammaro 10 ай бұрын
Great video. Can a 4-inch PVC backwater check valve be installed to replace an existing cast-iron 4-inch backwater check valve? Would you recommend it?
@balkanplumbing
@balkanplumbing 10 ай бұрын
Glad you liked the video. Unless the cast iron check valve is failing you, I’d say not to swap it out.
@JosephTammaro
@JosephTammaro 10 ай бұрын
Thank you@@balkanplumbing
@llamaj7j
@llamaj7j Жыл бұрын
I have an outdoor storm drain (7" diameter hole in the ground, with a ~3" horizontal pipe) that backs up during heavy Manhattan rains. Is this the type of issue a check valve could solve?
@pacmanzz
@pacmanzz Жыл бұрын
yes
@balkanplumbing
@balkanplumbing Жыл бұрын
Honestly, in almost all cases no. If you install a sewer valve on a storm line it does prevent backup (aka surcharge) from the public sewer. But then the storm water from your property has no place to go. Sewer valves are primarily for sanitary surcharges from public sewers. Hop that helps.
@llamaj7j
@llamaj7j Жыл бұрын
@@balkanplumbing thanks for the reply! I am wondering if there is another solution you have employed in this scenario? The water that backflows seems to be entirely rainwater from the storm sewer. I can't think of another way to prevent the backflow and the band-aid solution of using a submersible utility pump to remove excess water doesn't seem ideal... Any ideas?
@balkanplumbing
@balkanplumbing Жыл бұрын
This would require a site visit by a professional and licensed plumber. If you’re in NYC, we provide that for free and without any obligation.
@JosephTammaro
@JosephTammaro 10 ай бұрын
Great video. I have a follow-up question. Example: Heavy rain. Check valves check. All the rainwater on your property has nowhere to go. Suggestions? @@balkanplumbing
@roybatty-
@roybatty- Жыл бұрын
What happens if you install the backflow valve after the house trap, on the house side?
@balkanplumbing
@balkanplumbing Жыл бұрын
A potential disaster: all of the pressure of backed up waste water from the city sewer will be pressing up against the trap plugs, trying the blow them out. The sewer valve should therefore always be on the street side of the trap.
@roybatty-
@roybatty- Жыл бұрын
@@balkanplumbing Wow, how much pressure are you talking about? If the caps are tight and sealed, they can still blow? Why won't the cap off the backflow valve blow then?
@balkanplumbing
@balkanplumbing Жыл бұрын
Sewer valves are specifically designed to handle the pressure. Sewer trap plugs are not and can wear out. Act accordingly or as you said choose. Good luck!
@roybatty-
@roybatty- Жыл бұрын
@@balkanplumbing Unfortunately I am in a situation where the back flow valve is after the house trap in the basement. The house trap has two steel cleanout plugs screwed inside steel end caps which are clamped to the house U-trap via 4 inch flexible couplings. I ratcheted down all the clamps firmly and they are really tight on there. I hope they can handle the pressure from a back up. 🤞
@nonhlanhlamthembu7437
@nonhlanhlamthembu7437 10 ай бұрын
Hi, I need the pvc check valve ASAP. Which company I can order it online
@balkanplumbing
@balkanplumbing 10 ай бұрын
Cyclone Valves.
@chinaDENJ25
@chinaDENJ25 Жыл бұрын
I want to know the Wi-Fi alarm sewer backup
@balkanplumbing
@balkanplumbing 11 ай бұрын
Where exactly are you located?
@philipa3811
@philipa3811 Жыл бұрын
Needed to see how the cast iron one looks from inside and d😅don’t do it 😢
@balkanplumbing
@balkanplumbing Жыл бұрын
If you look through our channel we have a few cast iron check valve videos. FYI
@balkanplumbing
@balkanplumbing Жыл бұрын
kzbin.info/www/bejne/qJi3emefo9-hn8U
@WeTubule
@WeTubule 7 ай бұрын
Both are flapper valves it seems. Disappointing that each valve, brand new with best possible seal condition, can leak a steady stream of sewage back into your house.
@garyscarborough7797
@garyscarborough7797 11 ай бұрын
Would that work for keeping snakes from entering your home
@rzqdzn
@rzqdzn Жыл бұрын
Who is responsible for installing these check valves? The home owner or city?
@balkanplumbing
@balkanplumbing Жыл бұрын
100% the property owner. No idea why they’re not mandatory when a house is built.
@mikechirhart708
@mikechirhart708 11 ай бұрын
​@@balkanplumbing They are here in Minnesota!
@CloudfeatherRusticWorks
@CloudfeatherRusticWorks 3 ай бұрын
Link to the check valve?
@balkanplumbing
@balkanplumbing 3 ай бұрын
In the video description, no?
@CloudfeatherRusticWorks
@CloudfeatherRusticWorks 3 ай бұрын
​@balkanplumbing there's a link to a page that has a more in-depth guide that relates to this video, but I'm not seeing anywhere to purchase one of these, or a link to buy.
@balkanplumbing
@balkanplumbing 3 ай бұрын
@@CloudfeatherRusticWorks Look up Cyclone Valves. Hope that works! Mention Balkan.
Backwater Valve Installation
7:44
cityofwindsor
Рет қаралды 329 М.
House Sewer Traps: How A Sewer Trap Functions On Your Drain System
5:12
Balkan Sewer & Water Main Service
Рет қаралды 73 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 9 МЛН
Вы чего бл….🤣🤣🙏🏽🙏🏽🙏🏽
00:18
Идеально повторил? Хотите вторую часть?
00:13
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 18 МЛН
Sioux Chief ProCheck™
3:31
SiouxChiefPRO
Рет қаралды 86 М.
Stop Basement Sewer Flooding: Sewer Flood Gate Valve Demonstration
6:24
Balkan Sewer & Water Main Service
Рет қаралды 7 М.
Backwater Valve failure vs  performance
1:44
Flood Ready
Рет қаралды 55 М.
Demo of Sewer Backflow Prevention Device at ACE 2010
4:03
pwgroup
Рет қаралды 257 М.
Fernco - Backwater Valve Installation Video
1:35
Fernco Ltd
Рет қаралды 2,3 М.
Sewer Valves Explained: Different Types Of Sewer Backwater Valves
4:08
Balkan Sewer & Water Main Service
Рет қаралды 14 М.
Types of Check Valves for Wastewater Applications
7:51
R.C. Worst & Co., Inc.
Рет қаралды 53 М.
Mainline Backflow Valve installation, Part 3
12:52
The Lo-fi Mofo
Рет қаралды 56 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 9 МЛН