#495

  Рет қаралды 8,753

IMSAI Guy

IMSAI Guy

Күн бұрын

Пікірлер: 30
@allenmarian2005
@allenmarian2005 3 жыл бұрын
IMSAI Guy, your videos are gold mine. Every video deserves to be downloaded and archived.
@californiakayaker
@californiakayaker 4 жыл бұрын
I've got a very old one, produced by motorola by someone and sold as part of their required test equipment in the 70s. 26as101-1 One way I use it is to run it directly to a dummy load, and put an atenuator on the sample input/output, and a sig gen on that. I can measure receiver sensitivity without having to worry about tx. blowing the test gen.
@kingsman428
@kingsman428 3 жыл бұрын
*"... What's this thing?..."* Looks like the kind of thing that Gerry Anderson would use as a model in Thunderbirds, Captain Scarlet or UFO
@Creatortech95
@Creatortech95 2 жыл бұрын
please make a video about RF amplifier Phase maching and power combining
@IMSAIGuy
@IMSAIGuy 2 жыл бұрын
I have some already, search my channel for amplifier and splitter (used backward for combining)
@Creatortech95
@Creatortech95 2 жыл бұрын
@@IMSAIGuy please tell me Can we use Vector Network Anylizer for phase maching And I have 2kw Rf amplifier wih 8to 1 combiner all rf amplifier have more than 1.5kw individual out put power but when i connect these amplifier to cmobiner it output show less than 4kw is it happen with phse maching error or impedance maching Amplifier range is 1250mhz to 1350mhz pulse amplifier
@IMSAIGuy
@IMSAIGuy 2 жыл бұрын
@@Creatortech95 that is a large system and not all can be measured with a VNA, but certainly you can measure things like the electrical length of the different paths, the %transmission of things, and the SWR at various points. Since it it portable, measurements at the antenna are possible. all the measurements are done at milliwatt powers so it will not account for loss do to high power. I don't have any real experience.
@Creatortech95
@Creatortech95 2 жыл бұрын
@@IMSAIGuy thanks this module use for Radar and it is tha finel out of 10kw if the total output more than 8kw then we can switch on CFA and it power up to 100kw this is old military radar can i know what is tha basic instrument use for pahse matching We have Vector Network anylizer ,signal anylizer , oscilascope powermeter frequency counters And yesterday i power the amplifier and use vna with ratio b1 /b2 and use attenuater and coupllers to reduce output power to -10dbm because vna cant handle too high power Then frequency genadator out certain frequency but the vna show it varied highly. -30 dgree to 160dgree. So i remove amplifier and connct vna to signal genarator with coupler but it show phase angel pin point
@johnwest7993
@johnwest7993 2 жыл бұрын
While that 50 terminator may never be removed, if you wanted to analyze a 75 Ohm cable you can just replace the 50 Ohm terminator with a 75 Ohm terminator and the coupler will work just fine at the new impedance.
@W1RMD
@W1RMD 2 жыл бұрын
Could one be made for 300 ohms?
@AECRADIO1
@AECRADIO1 4 жыл бұрын
The 20dB is for the coupled port. The load is for the coupled port, pre-set impedance. The dB rating comes from the coupled port distance from the main line. X input, coupled to sample port 20dB lower level.
@IMSAIGuy
@IMSAIGuy 4 жыл бұрын
Thanks. that makes perfect sense
@vidasvv
@vidasvv 4 жыл бұрын
Nice tutorial about couplers. What rev firmware are you using on your NANO ? 73 N8AUM
@IMSAIGuy
@IMSAIGuy 4 жыл бұрын
Feb 23 2020
@vidasvv
@vidasvv 4 жыл бұрын
@@IMSAIGuy TNX 4 reply
@andrelubbock
@andrelubbock 4 жыл бұрын
Thanks - interesting. It's a shame we can't see connections to the coupler while dong noise floor measurements .
@IMSAIGuy
@IMSAIGuy 4 жыл бұрын
CH1 connected directly to 50ohm load. no input to the nano
@Tchipo100
@Tchipo100 3 жыл бұрын
Fantastisch simple explanation of difficult things ! Tex vo much ! On4 SG
@Flamenawer
@Flamenawer 2 жыл бұрын
What you did in the last part to measure the noise floor, and why? It cannot be seen and you don't explain so only you know it,.or someone that knows already,.but that people dont see this videos. Please, explain more the things your videos interest me but always there is important points that just get lost by the cameras or other reasons. explain what is seen in the screen s11? S21?
@IMSAIGuy
@IMSAIGuy 2 жыл бұрын
I have a playlist 'nanovna' I think there are 60 video for you to learn from
@Flamenawer
@Flamenawer 2 жыл бұрын
@@IMSAIGuy thanks by made them
@W8ASA
@W8ASA 4 жыл бұрын
Not 50MHz-2.4GHz. Their published data sheet shows 500MHz to 2 GHz.
@IMSAIGuy
@IMSAIGuy 4 жыл бұрын
I said it right at 15:44 then messed up at the end
@WiteexLC
@WiteexLC 2 жыл бұрын
Its look like ANAREN brand coupler.
@Flamenawer
@Flamenawer 2 жыл бұрын
Yeah. , The color is that
@Peter-W1
@Peter-W1 4 жыл бұрын
500 MHz to 2 GHz otherwise perfect video next up maybe a circulator if you have one 👍😎
@IMSAIGuy
@IMSAIGuy 4 жыл бұрын
No I don't have one. Do they operate below 1GHz?
@W8ASA
@W8ASA 4 жыл бұрын
@@IMSAIGuy Yes, circulators work down into the MHz region.
@glasslinger
@glasslinger 3 жыл бұрын
@@IMSAIGuy If you find some of the older cell phones that had a black box full of electronics there are several circulators that operate in the 800mhz region.
#496 Noise Gate Design Error
4:33
IMSAI Guy
Рет қаралды 1 М.
#620 Bridge or Coupler? Which is better?
16:43
IMSAI Guy
Рет қаралды 11 М.
Their Boat Engine Fell Off
0:13
Newsflare
Рет қаралды 15 МЛН
ВЛОГ ДИАНА В ТУРЦИИ
1:31:22
Lady Diana VLOG
Рет қаралды 1,2 МЛН
#196: How a Directional Coupler in an SWR meter works
21:47
#1366 RF Bridge
12:07
IMSAI Guy
Рет қаралды 16 М.
#576 NANOVNA Measuring an Amplifier
13:30
IMSAI Guy
Рет қаралды 30 М.
2kW Directional Coupler for LDMOS Amlifiers
12:46
Radio Electronics
Рет қаралды 41 М.
#1470 Using RF Couplers for Return Loss Measurment
19:02
IMSAI Guy
Рет қаралды 7 М.
Little inductance measurement test with NanoVNA/LiteVNA
7:58
Dummy Load
Рет қаралды 1 М.
#1478 RF Coupler Construction
24:52
IMSAI Guy
Рет қаралды 10 М.