5 Plumbers Couldn't Fix The Heat Radiant Zones Heat Up Entire House - No Problems Only Solutions!

  Рет қаралды 16,326

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

2 жыл бұрын

This new client had 5 other plumbers come to fix their heating system. We diagnosed the issue and completed repairs in under an hour!
Helpful Links
Pilot & Thermocouple Wrench amzn.to/3ke56J4
Wago 221 Lever Wire Connectors: amzn.to/3vAnWyw
Knipex Wire Striper: amzn.to/3ARJS9n
ServicePal Mobile DIspatching & Invoicing App: app.servicepal.com/account/si...
Please support this channel and Mikey Pipes and consider the following…
Merchandise Requests (United States Only):
Official Pipe Doctor tee-shirts are available in Large & XL - minimum donation of $28 is appreciated
Official Pipe Doctor FlexFit Embroidered Caps - minimum donation of $37 is appreciated
Tee-shirt & Cap donations and I will also include a Pipe Doctor pen
(If you are international - please add a minimum of $40 for shipping/postage)
I ship USPS Priority Mail. Want a shirt or hat? Email me: mike@mikeypipes.com Payment links are below.
Magnets $8.50 each shipped globally and comes with 2 stickers.
I am on Discord & WhatsApp! These extended communities often gets a sneak peak on videos before I make them public on KZbin
Discord: / discord
WhatsApp Group: chat.whatsapp.com/CHZWtZe4KMG...
Shopping on Amazon? I'll get a small affiliate commission if you save and bookmark this link:
amzn.to/2PjjS4v
THIS DOES NOT COST YOU ANYTHING! Plus I get a small referral commission which equals more #giveaways - So click the link!
Free Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
Summer-Fall 2021 Version 3.0
Consider donating $7.50 or ANY amount and you will receive Version 3.0 & Version 1.0 - regardless where you live in the world. Postage is included.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Plumbing
80 E Hawthorne Ave
Valley Stream, NY 11580

Пікірлер: 121
@eddiew.6485
@eddiew.6485 2 жыл бұрын
Sounds like the Customer is very Happy 👏. Customer for Life!
@purplegoose7907
@purplegoose7907 2 жыл бұрын
Save money...call the BEST the first time. Good job Mikey. The people have been fed!
@jonbailey6928
@jonbailey6928 2 жыл бұрын
@@PipeDoctor Always hungry for your content keep up the good work
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
Mikey Pipes you're a real champ!
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
Your deducting thinking arrived at a solution to the problem where 5 other cos. failed!
@metalhead24922492
@metalhead24922492 2 жыл бұрын
Brutal when the customer knows more about there system than “ qualified professionals “. Gotta feel good to get her fixed up
@davidriccitiello6421
@davidriccitiello6421 2 жыл бұрын
I'm just overwhelmed how you can trouble shoot in a split minute, your gold mike.
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
Mikey is experienced and solves problems!
@mattbauckman9907
@mattbauckman9907 2 жыл бұрын
Editing. 😉
@davidriccitiello6421
@davidriccitiello6421 2 жыл бұрын
Mike shoots right from the hip live, his diagnostic skills are top notch.
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
@@davidriccitiello6421 Yes!
@glendurant911
@glendurant911 10 ай бұрын
Yes the thermal imager is great idea, and i love your finding the wiring default.
@PipeDoctor
@PipeDoctor 10 ай бұрын
Cool, thanks
@FB-111A
@FB-111A 2 жыл бұрын
i ABSOLUTLY LOVE MIKEY & PETER PIPES - DANIELSON LOOKING FORWARD TO THE NEXT VIDEO
@deejohnson5163
@deejohnson5163 2 жыл бұрын
LOVED THE VIDEO. Most of what you did confused me, but i still think i learned something (not in the trades ). I like how you used an infrared scanner to verify your repair and were able to show the customer that you fixed it. That circulator looked pretty funky. Should have a pt 2 when your co-worker goes back for draining and tuneup.
@Fenrir414
@Fenrir414 2 жыл бұрын
Straight and simple @Mikey Pipes, if the tech is used for the job and helps to get the job done, then the tech can be used, but if impedes the work or causes issues, then can be thrown in the rubbish bin
@joemoreno4438
@joemoreno4438 2 жыл бұрын
Mikey pipes you're the best keep it up
@billtorres6027
@billtorres6027 2 жыл бұрын
Great call Mike!!!
@petem6291
@petem6291 2 жыл бұрын
Mike you checked and tested and tested your findings nice job . The diagnosis is the hardest part . Do you think that house needed two water heaters ????
@davidlampe4153
@davidlampe4153 2 жыл бұрын
I listened to the introduction but didn’t know how to fix it. Watched you point out the wiring but didn’t know what it meant. Great job on the diagnosis and the secondary effort with the circulator pump.
@Silky_boi
@Silky_boi 2 жыл бұрын
You dropped this Mikey….. 👑
@Sturgisreef
@Sturgisreef 2 жыл бұрын
That PRV is just waiting to take out those zone controls!
@imthatguy1878
@imthatguy1878 2 жыл бұрын
Truth
@patmurphy2472
@patmurphy2472 2 жыл бұрын
Nice troubleshooting. Aqua stat is the switch, good description.
@matthewviti2241
@matthewviti2241 2 жыл бұрын
Love these boiler video
@kellymoran3175
@kellymoran3175 2 жыл бұрын
NO...thank you Mikey Pipes for all you do for us subscribers! You have a must see channel and the thing I respect the most about your way of operating is that you are ETHICAL and HONEST in a time when many are not. Just a side note... I respect your commen sense views on how things really are these days (politically) and what not. God bless you Mikey and thank you once again for what you do and just being a STAND UP GUY! PEACE!
@catslivesmatter1268
@catslivesmatter1268 2 жыл бұрын
The only time when any of us HVAC technicians lay down is when we have to get into a crawl space 🌌 lol
@DevinHVACInc
@DevinHVACInc 2 жыл бұрын
Experience beats all. There were no testing there. Just experience takes u to the wires. Awesome find.
@mattbauckman9907
@mattbauckman9907 2 жыл бұрын
In my neck of the woods (CT) you don’t want a plumber for anything other than toilets and faucets. If you want a heating or cooling problem diagnosed and fixed you call an HVAC tech. I was thinking as you removed those covers from the relays that if they had gotten swapped (labels) your troubleshooting would have taken a little longer. 😂. I’ve been a victim of incorrectly labeled equipment.
@skeedebug
@skeedebug 2 жыл бұрын
Damn good job Mikey!
@martinelizarazo5862
@martinelizarazo5862 2 жыл бұрын
You are in a different level I like you attitude
@ronzo9377
@ronzo9377 2 жыл бұрын
Your modern-day plumber nice Gadget to see that radiant heat
@imthatguy1878
@imthatguy1878 2 жыл бұрын
Love that relief valve dumping at the relay
@doctorjohn-burgtekie
@doctorjohn-burgtekie 2 жыл бұрын
With the other plumbers they were not testing so these guys were guessing, nice work Mickey.
@bradmironik6137
@bradmironik6137 2 жыл бұрын
For the type of work you encounter the flir is a good tool to have. What I'm trying to understand is how a steam boiler is incorporated into radiant zones. I get to enjoy stuff you deal with that I will never see in my career. Thanks.
@petersmart1999
@petersmart1999 2 жыл бұрын
Making hot water with steam by using the heat exchanger or you can just use another water heater,all kinds of tricks in the trade
@bradmironik6137
@bradmironik6137 2 жыл бұрын
@@petersmart1999 Thanks for the reply. I did hear mikey say something about a heat exchanger.
@consolidatedplumbingandhea4390
@consolidatedplumbingandhea4390 2 жыл бұрын
Paused at 1:43 into the video so without seeing the boiler. Had a couple of them, installation of a strap on aquastat on the steam riser that killed the call for the boiler burner to run if set point was made but not call for steam solved the issue. Given just ounces of steam can travel the immersed aquastat may not react in time. 3:30 Best place for the aquastat is in the boiler and branched off the piping like that I doubt the well is in the flow. Flat plate heat exchanger will plug up in no time, use of an Everhot tank with more open passage would last longer. Old B&G 100's also have a better passage than the 007's that will burn out in not time. I think the relief with an open vent over the controls is a great idea, will put the system out of it misery. Given in the end the controls were not wired right. Still seems the overall application of how things were done will remail a complication. That they are radiant zones not baseboard does help mask the issues given your running at a lower temp that have a bigger gap in temp then equipment that needs 180F to function well.
@rupe53
@rupe53 2 жыл бұрын
would agree the aquastat well was not in the perfect place but a call for radiant would turn on the circ and bring that pipe up to temp fairly fast... IF.... the water was flowing. (was not flowing due to issues) That said, how long (how many years?) can you have a problem like this and nobody figured out the wiring was wrong? All of that stuff was not new last week.
@jfoley1968jf
@jfoley1968jf 2 жыл бұрын
Mikey technology is a major help but not knowing how a system works or the sequence of operation its useless thats what separates the pros from the hacks. Great job!!
@dh4971
@dh4971 2 жыл бұрын
That was interesting. Being that electrical is my weak point i would have been going nuts. But i had a feeling something would have been wired incorrectly at a zone panel of some sort
@repairman2540
@repairman2540 2 жыл бұрын
Yes to Hi-Tech testing. But the testing of switches and Relays is what makes you a Master Plumber / Troubleshooter and that is very hard to find. Here in Bucks PA we have lots of Hot Water Systems and few Mechanical Contractors.
@malachy1847
@malachy1847 2 жыл бұрын
"If you're Not Testing... you're Guessing..."
@NelsonSteffens
@NelsonSteffens 2 жыл бұрын
I was thinking maybe a flow check issue if she doesn't have zone valves but I ain't no plumber lol
@tonyc3147
@tonyc3147 2 жыл бұрын
Love technology to help during calls, a lot of old timers don’t
@whodat1473
@whodat1473 2 жыл бұрын
Nice job and good videos, the only other issue is the plate heat exchanger should be flushed if that circulator was that clogged
@tphvac87
@tphvac87 2 жыл бұрын
Zones wired wrong, just started watching video!! Not cheating
@theduffster2581
@theduffster2581 2 жыл бұрын
I also have a flir and find radiant leaks quickly
@ivan79uk
@ivan79uk 2 жыл бұрын
Nice 👌 one Mike. I'm thinking to get one thermo camera. Automatic transmission the best. Been driving for 10 years now, never back to manual. Here in UK&Europe most people drives manual.
@joemartinez7765
@joemartinez7765 2 жыл бұрын
Yes. When clients can see , what you found. Bingo.
@thtdudenamdbilly
@thtdudenamdbilly 2 жыл бұрын
I wish Mikey served upstate NY.
@bruceelias2732
@bruceelias2732 2 жыл бұрын
Mikey This happened to me , and I have hot water heat boiler. In my case it was a run away thermostat years ago I believe.
@kevincreager
@kevincreager 2 жыл бұрын
Hi Mike what episode did you cover service pal and do need a mac computer in the office to interface or will our PC work that we run Quickbooks on? Thanks
@jaymattheating2294
@jaymattheating2294 2 жыл бұрын
First question did it ever work properly?? If yes I'm going zone valve bleed by of not bad install
@modestohodesto7140
@modestohodesto7140 2 жыл бұрын
Great job Mike. Quick question the aqustat for the radiant temps out before the boiler makes steam and heats the rest of the non radiant?
@mnhvacguy9788
@mnhvacguy9788 Жыл бұрын
But at those low temps isn't flue gas condensation an issue? The aquastat was set for 130degF, the same temp that natural gas exhaust will start to condense. I'm a hot water boiler guy of 25 years but there's very little steam in my area so my experience is limited with it, most have been converted over to hot water years ago
@davidriccitiello6421
@davidriccitiello6421 2 жыл бұрын
Mike if that unit worked before the issue, how did the wiring get mixed up?
@jlangiu
@jlangiu 2 жыл бұрын
Mikey pipes you need big boy sizes!
@markcollins457
@markcollins457 2 жыл бұрын
Is the aquastat wired to make or break on temp rise ?
@1022hard
@1022hard 2 жыл бұрын
Love the technology! If you’re not testing you’re guessing, right?
@compactc9
@compactc9 2 жыл бұрын
As long as its not just a gimmick, I love technology. Work smarter, not harder!
@fastidol5245
@fastidol5245 2 жыл бұрын
Yes! Use technology whatever gets the job done RIGHT
@joemartinez7765
@joemartinez7765 2 жыл бұрын
What Regulates each circuit? Is what I ask my self. On a call like this.
@gregclaiborne3691
@gregclaiborne3691 2 жыл бұрын
The old saying ! Work Smarter! Not Harder!!!!
@buixote
@buixote 2 жыл бұрын
I'm surprised you didn't recommend installing some *supports* for all those hanging pipes...
@northface484
@northface484 2 жыл бұрын
The Pigtail is technically called a "Siphon"....
@northface484
@northface484 2 жыл бұрын
@@PipeDoctor If you answer "Pigtail" on a test you are going to be wrong...:)
@brendandrury2177
@brendandrury2177 2 жыл бұрын
Well done, Socrates, with Peter Pan in this video.
@Extra_digits
@Extra_digits 2 жыл бұрын
“Peoples Champ”
@juleskenneth6934
@juleskenneth6934 2 жыл бұрын
Weil-McLain EG series steam boilers are one of very few that can be ordered with a built-in domestic hot water coil. If the customer's boiler would have used a built-in coil for circulating hot water to the radiant zones, there would be no circulating pump moving filthy boiler water through a heat exchanger. Instead, there would be just the zone circulaters handling clean hot water from the built-in coil. AND, the domestic coil has a tapped well for the aquestat limit switch. Too bad more gas-fired steam boiler manufacturers don't offer built-in domestic hot water coils. They are trouble-free when used to provide circulating hot water zones off a steam system.
@kf_boston
@kf_boston 2 жыл бұрын
🤜🤛 flat plate/sidearm 🔥
@mikemartel9515
@mikemartel9515 2 жыл бұрын
Not much steam around here but would a bronze or stainless circulator not be a better choice for this application with all the oxygen being introduced?
@mikemartel9515
@mikemartel9515 2 жыл бұрын
The black iron pipe will still get gunked and plugged up eventually but at least the circ will be clear as long asthe check valve is removed. We have alot of poly B heating systems here if i run into one i use a plate heat exchanger and all nonferos piping on the system side to protect the boilers.
@georgewashington8652
@georgewashington8652 2 жыл бұрын
not all plumbers are heating TECHS when a plumber installs a boiler he gets a electrician to wire it a heating tech doing the whole job from start to finish
@markjacobs3379
@markjacobs3379 2 жыл бұрын
A bad circulator check valve?
@ricklee827
@ricklee827 2 жыл бұрын
Should have installed a drip leg on that relief valve
@turbo2ltr
@turbo2ltr 2 жыл бұрын
If that circulator had all that shmoo, I could imagine what that heat exchanger looks like inside.
@markcollins457
@markcollins457 2 жыл бұрын
Is the aquastat a spdt stat
@markcollins457
@markcollins457 2 жыл бұрын
@@PipeDoctor like your show, I'm now semi retired but spent many years with a Honeywell dist. In jersey factory trained on controls and youf logic towards trouble shooting is something that's not taught the same as today's mechanics there were no mother boards just "A" control for (1) job used with another ie:high or low limit pressure temp humidity etc. Keep teaching its your strong point!
@johngallati8164
@johngallati8164 2 жыл бұрын
THAT IS AN ABSOLUTE LOUSY WAY TO HEAT..STEAM FOR STEAM ONLY PERIOD..SHEL ALWAYS HAVE PROBLEM S
@orreymodo5860
@orreymodo5860 2 жыл бұрын
Do both circulators come on? I guessing zone wiring mess up, also after watching it I love that no drip leg pressure relief value pointed right a Taco control board - Zap!!
@chuckquinn8026
@chuckquinn8026 2 жыл бұрын
Hacks bring me stacks…
@dwaynerenton1889
@dwaynerenton1889 2 жыл бұрын
Who is your new guy Mike?
@williamdawson6351
@williamdawson6351 2 жыл бұрын
If you stay in the past the future will pass you by and leave you wondering how the others in your field of work are doing so much better, you need to use the new tech to get ahead.
@frmerrin2
@frmerrin2 2 жыл бұрын
Plugged heat exchanger?
@effylowy7961
@effylowy7961 2 жыл бұрын
Nice job wich pump did use
@MrRosemore1234
@MrRosemore1234 2 жыл бұрын
i was going to say tstat wires are crossed
@MrRosemore1234
@MrRosemore1234 2 жыл бұрын
were i live at in ohio we dont have steam boilers or radical heat systems, all i have seen are gas furnace, electric heat, and or heat pumps, and i do engineering / building maintenance for 2 hotels for the last 15 years and i was straight from high school and everything i know now was self taught with never dealt with what you did in this video or seen but yea i guess i was close, keep up the hard work and awesome videos, you're videos have teach me something new everyday and i hope the new plumbers learned from them
@19rappy
@19rappy 2 жыл бұрын
Get hoodie’s made
@beacjere284
@beacjere284 2 жыл бұрын
i think zone valves are not working correctly 1:42
@dustinweber6803
@dustinweber6803 2 жыл бұрын
Maybe the unit is getting too hot, producing steam and through gravity heating everything, the control isn't set properly?
@rupe53
@rupe53 2 жыл бұрын
the fact that it's a steam boiler is half the answer. The boiler should NOT heat the main house unless it's making steam. If it makes steam any other time then there's a problem. He was right to start looking at controls first, although it's usually a bad control, not a bad install. That's part of the detective work to sort that out.
@pizzareviewwithkarrighione5576
@pizzareviewwithkarrighione5576 2 жыл бұрын
Technology is good. in your own words of wisdom.If you ain't testing your guessing.
@Jordybrady
@Jordybrady 2 жыл бұрын
Electrical voltage issue my guess let’s see
@northface484
@northface484 2 жыл бұрын
Stats wired incorrectly...
@fredthompson2501
@fredthompson2501 2 жыл бұрын
Wow kid I thought you where a master plumber no where in the intro did you mention the Flux capacitor or the Newton relay or a bad warp condescending coil.
@michaelmyers4999
@michaelmyers4999 2 жыл бұрын
I think the zone valves are wired wrong.
@busman2000
@busman2000 2 жыл бұрын
The whole housing heating is all interconnected somewhere other than near the boiler..? Nightmare On Elm part X.lol
@joeymorrone3091
@joeymorrone3091 2 жыл бұрын
Could possibly be a bad relay control...or maybe flowchecks are bad allowing migration of heat
@rupe53
@rupe53 2 жыл бұрын
why would you ask that now after he found the problem and it's already done?
@rupe53
@rupe53 2 жыл бұрын
@@PipeDoctor ... I'll give you that one because you did ask. OTOH, the clue up front was in your wording that it was a steam system and the steam section of the house can only heat if the boiler makes steam. Having worked on a few of these systems some 30 years ago my mind was already toying with why the boiler was firing so long if there was no call from the t-stat. Obviously this issue didn't just pop up last week.
@bruceelias4401
@bruceelias4401 2 жыл бұрын
Mikey!!!
@rustyshakleford5230
@rustyshakleford5230 2 жыл бұрын
This is one of those terrible installs that you will 100% be called back for at some point this winter. Who would hang those circs out in the breeze when the wall is right there.
@steveblake8766
@steveblake8766 2 жыл бұрын
#326 thumbs up
@bahopik
@bahopik Жыл бұрын
Isn't ECM pump acts like a magnet and without a magnetic dirt separator will quit working soon? I thought that's what Taco folks wanted
@Wolfhound.
@Wolfhound. 2 жыл бұрын
so if the relief opens it will just flood water onto the taco box nice
@KyleShears
@KyleShears 2 жыл бұрын
I'm guessing aquastat
@KyleShears
@KyleShears 2 жыл бұрын
@@PipeDoctor well, there was a bit more to it than that
@rjv1415
@rjv1415 2 жыл бұрын
Technology is great but some items are overpriced. crooks
@cybershot123
@cybershot123 Жыл бұрын
wired wrong zones
@brianmorris7498
@brianmorris7498 2 жыл бұрын
Hi mike! Can we set up a scholarship for some young kid to attend a private vocational high school for plumbing / hvac? I believe the viewers would love this idear and would love to contribute,I would be the first!! Just a idear
@brianmorris7498
@brianmorris7498 2 жыл бұрын
How about…..The “Pipe Doctor Foundation “! 😀
@chrisE815
@chrisE815 2 жыл бұрын
Hey what ever happened with that boiler radiant hack job where the idiot used a used marine heat exchanger?
@johnguerrero4305
@johnguerrero4305 2 жыл бұрын
The problem: a plumber was on the job and not a HVAC tech? Lol
@throttlebottle5906
@throttlebottle5906 2 жыл бұрын
majority of plumbers shouldn't touch anything with wiring or power! 😏
@craigherron1203
@craigherron1203 2 жыл бұрын
Paid for itself again. Only shows knowledge of the proven technology works well
@Rainmaker88
@Rainmaker88 2 жыл бұрын
Taco 100 or find another company.
@scottk0623
@scottk0623 2 жыл бұрын
Anybody who put a plate exchanger and or a circulator on a STEAM system and didn’t put a STRAINER on it should go and sell burgers. Any circulator used without a strainer will not last.
@bobbyossenbeck6402
@bobbyossenbeck6402 Жыл бұрын
People who don't like tech aren't that profitable or could be more profitable although a hack is just a hack in dire need of education
@realestateservicessaleshea99
@realestateservicessaleshea99 2 жыл бұрын
Embrace the tech!! I love a manual transmission ! KISS ! 🥃🥃🍺🍺🍺🎯🍿🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!
Their House Could Of Have Blown Up! Huge Gas Leak on Brand New Williamson Steam Boiler Found!
41:40
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 25 М.
Central AC Not Cooling Properly & Freezing Up - TXV Metering Device Restriction Diagnosed & Repaired
26:54
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 7 М.
- А что в креме? - Это кАкАооо! #КондитерДети
00:24
Телеканал ПЯТНИЦА
Рет қаралды 7 МЛН
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 195 МЛН
Became invisible for one day!  #funny #wednesday #memes
00:25
Watch Me
Рет қаралды 60 МЛН
Clown takes blame for missing candy 🍬🤣 #shorts
00:49
Yoeslan
Рет қаралды 40 МЛН
Montage des Mighty Bracket
1:41
Aspen Pumps Group
Рет қаралды 10 М.
Watch: Tucker Carlson full speech at 2024 RNC | LiveNOW from FOX
11:34
LiveNOW from FOX
Рет қаралды 1,5 МЛН
How Much Trash is in This Abandoned Barn! - World Headquarters Build!
28:31
John Wood Condensing Tankless Water Heaters
7:23
A. O. Smith Water Heaters
Рет қаралды 318
This Is Humbling!! Killed Our Own Crop!!
22:00
Larson Farms
Рет қаралды 151 М.
Backyard Custom Pool Fire & Water Features Repaired Jandy Grand Effects Ignition Module Replaced
14:36
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 607
If I touch this tower, I die
43:19
Geerling Engineering
Рет қаралды 1,1 МЛН
Самый ДОБРЫЙ мальчик!😎
1:00
Petr Savkin
Рет қаралды 2 МЛН
Сделали биотуалет в мерседесе
0:37
宠爱天使的小丑。#天使 #小丑 #超人不会飞
0:20
超人不会飞
Рет қаралды 9 МЛН
Triggle #настольныеигры #boardgames #games #игры #настолки #настольные_игры
0:48
Двое играют | Наташа и Вова
Рет қаралды 11 МЛН
казахи сделали мустанг🤯❗️
0:26
Профессор ПельменАрти💀
Рет қаралды 6 МЛН