5 Ways To Fix Open Ground Receptacles. With code references and visuals! How to fix an open ground.

  Рет қаралды 61,249

Electrical Code Coach

Electrical Code Coach

Күн бұрын

Пікірлер: 23
@abelferia1
@abelferia1 2 жыл бұрын
God Bless. Hello there brother in faith for life. Just reaching out to thank you and bless you for all you've done with the electrical community. I my self just passed the master's exam thanks to your dedication and passion for the electrical coaching, am 60 years old and believe me when I tell you the lord has given you a precious gift. Again keep up doing what you do many blessings for you and your family.
@ElectricalCodeCoach
@ElectricalCodeCoach 2 жыл бұрын
Congratulations!!
@Jesusbeliever1
@Jesusbeliever1 Жыл бұрын
I learned some good information on this short, to the point and very understandable information. Thanks a lot.
@noconsentgiven
@noconsentgiven Жыл бұрын
My day got better when I came to your channel❤️. Thanks Coach and God bless👍!!
@ElectricalCodeCoach
@ElectricalCodeCoach Жыл бұрын
Let's go!
@Gruntled2001
@Gruntled2001 2 жыл бұрын
Coach, thank you for sharing your knowledge with us 🤝
@anthonyelectric6045
@anthonyelectric6045 2 жыл бұрын
Hey coach I ran into this situation a long time ago when we didn’t have these many code or equipment options. Snaking new wire and #12 wire all over the place uhh. Great explanation as always 👍
@mikekares-b8q
@mikekares-b8q 2 ай бұрын
Many Older Homes had those Old two prong outlets and Old style Knob and Tube wires.
@chrispate2788
@chrispate2788 2 жыл бұрын
Great explanation coach 👍
@thomaswatson6960
@thomaswatson6960 2 жыл бұрын
great work
@gregsettle9725
@gregsettle9725 9 ай бұрын
Good video. There are so many opinions on the use of GFCI outlets to fix missing ground. Some say one downstream, some say all outlets must be GFCI. Who to believe?
@Sparky-ww5re
@Sparky-ww5re 2 жыл бұрын
Helpful video. While adding GFCI protection does not protect sensitive electronics, like your 50 inch smart TV plugged into a surge protector, it does provide personal shock protection, so it's important to note that while Code does allow this practice, it's not quite as good as having a true ground.
@jmichel70
@jmichel70 Жыл бұрын
Thank you,
@ElectricalCodeCoach
@ElectricalCodeCoach Жыл бұрын
You are welcome!
@martinfishersings
@martinfishersings Ай бұрын
If you install an individual GFCI, it will still light up as an open ground, correct?
@vince6829
@vince6829 2 жыл бұрын
Thank you for sharing your knowledge. Question: the second way to address a missing ground (rewire the location), involves running a new stretch of romex (e.g. 14-2), correct? Could it simply involve running a single green ground wire from the breaker box to the receptacle?
@ElectricalCodeCoach
@ElectricalCodeCoach 2 жыл бұрын
They are several ways in 250
@liberaltears1714
@liberaltears1714 Жыл бұрын
If I installed exterior outlets (because I don’t have any, built in the 50’s) could I drill a small hole through my old metal boxes and block house to run a short ground wire from the inside to the new outdoor outlets?
@88PeteZa
@88PeteZa Жыл бұрын
I have a garage with only one outlet in it. The outlet is not grounded. Would it be safe to go to earth with a physical ground outside via grounding spike?
@ElectricalCodeCoach
@ElectricalCodeCoach Жыл бұрын
I would contact a qualified licensed electrician!!
@88PeteZa
@88PeteZa Жыл бұрын
@@ElectricalCodeCoach absolutely
@wiley0714
@wiley0714 2 жыл бұрын
You buy a pack of pigtails. And then you connect the ground wire to the receptacle, and you connect the other end with a twist nut to the neutral. Can you sell the house and smile!
@johnrueb2257
@johnrueb2257 2 жыл бұрын
See above, that is illegal and unethical. DO NOT DO THIS.
5 ways ways to fix an "open ground" UPDATED Video in description!!
14:56
Electrical Code Coach
Рет қаралды 175 М.
3 Weird Ways to Ground a Two-Prong Electrical Outlet
7:18
Top Homeowner
Рет қаралды 113 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 4,4 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 18 МЛН
УДИВИЛ ВСЕХ СВОИМ УХОДОМ!😳 #shorts
00:49
Dangerous Open Ground Fix
6:07
Why Not DIY
Рет қаралды 44 М.
When and Why to separate Grounds and Neutrals.
10:32
Electrical Code Coach
Рет қаралды 286 М.
How to Fix an Open Ground
13:05
Sparky Channel
Рет қаралды 636 М.
People Are Adding Deadly Hacks to Outlets
8:54
LRN2DIY
Рет қаралды 1,1 МЛН
Will a Metal Box Alone Provide a Ground for Electrical Wiring?
5:47
Sparky Channel
Рет қаралды 147 М.
Can You Replace A 2-Prong Outlet With A 3-Prong?
12:55
Electric Pro Academy
Рет қаралды 71 М.
How To Replace An Outlet | Ungrounded to Grounded
9:20
Aaron Fixes Stuff
Рет қаралды 550 М.
#84 - Open Neutral Testing in 120v Circuits
8:57
The Tech Circuit
Рет қаралды 11 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 4,4 МЛН