What you think would cause my controls on all 3 stations to be stiff ? Fluid looks good. Pressure 75 psi.
@CarolinaMarineGroupCharleston17 күн бұрын
I would start with your charge valves. Everything works well otherwise? Hard to say without being there. But I would start there.
@rski103610 күн бұрын
@@CarolinaMarineGroupCharleston Yes, they all work fine; but just all stiff. So I let out the air first, but after, when the valve caps are opened will all the fluid in the tank and the two stations above it all drain out ??
@CarolinaMarineGroupCharleston9 күн бұрын
If you want you can call me and I may be able to help over the phone 860-209-7609
@BrianBHatteras43c7 ай бұрын
I thought all hynautic took MiL-H-5606A aviation hyd fluid (red)?
@CarolinaMarineGroupCharleston7 ай бұрын
No! 50/50 glycol with no additives. Or you can use the expensive Hynautic stuff. Most people use the 50/50. 😃 other systems do use the red hydro fluid but not this.
@AD-bt3wv7 ай бұрын
Sounded like a piggy back filled with coins Captain.